Cation exchange membranes (CEMs) are widely used in many applications. The fixed anionic groups e.g., COO , –SO3 - , etc. in the polymer matrix ideally allows the passage only of oppositely charged cations, driven by a potential or a concentration gradient. Anions, charged negative, the same as the membrane matrix, cannot pass through the membrane due to electrostatic repulsion. Such “Donnan-forbidden” passage can, however, occur to some degree, if the electrical or concentration gradient is high enough to overcome the “Donnan barrier”. Except for salt uptake/transport in concentrated salt solutions, the factors that govern such Forbidden Ion Transport (FIT) have rarely been studied. In most applications of transmembrane ion transport, whether electrically driven as in electrodialysis, or concentration-driven, it is the transport of the counterion to the fixed charged groups, such as that of the proton through a CEM, that is usually of interest. Nevertheless, CEMs are also of interest in analytical chemistry, specifically in suppressed ion chromatography. As used in membrane suppressors, both transport of permitted ions and rejection of forbidden ions are important. If the latter is indeed governed by electrostatic factors, other things being equal, the primary governing factor should be the charge density of the membrane, tantamount to its ion exchange capacity (IEC). In fabricating microscale suppressors, we found useful to synthesize a new ion exchange polymer that can be easily molded to make tubular microconduits. Despite a high IEC of this material, FIT was also found to be surprisingly high. We measured several relevant properties for thirteen commercial and four custom-made membranes to discover that while FIT is indeed linearly related to 1/ IEC for a significant number of these membranes, for very high water-content membranes, FIT may be overwhelmingly governed by the water content of the membrane. In addition, FIT through all CEMs differ greatly among strong acids, they may still be transported as the molecular acids and the extent is in the same order as the expected activity of the molecular acid in the CEM. These results are discussed with the perspective that even for strong acids, the transport does take place as un-ionized molecular acids.
more »
« less
Functionalization of High‐Density Polyethylene Capillaries for Open Tubular Ion Chromatography
ABSTRACT Ion chromatography is the anion analysis benchmark. A miniature form, Open Tubular Ion Chromatography (OTIC), has attractive attributes for efficient ion separations. Here, we fabricate and characterize high‐density polyethylene (HDPE) open tubular anion exchange columns (OTCs). We attach positively charged latex particles onto negatively charged capillary surfaces. For efficient OTIC, column diameters need to be < ∼20 µm; functionalizing the bore is challenging. Methods to introduce acid groups to an HDPE capillary bore, e.g., sulfonation using chlorosulfonic or sulfuric acid solutions, with or without grafting of an aromatic ring through photo‐ or chemical grafting first, are explored. Following quaternary ammonium latex attachment, the ion exchange capacity and separating abilities of each OTC were measured as an index of OTC performance. Gradual loss of capacity was observed for many of these; high‐resolution mass spectrometry confirmed the leaching of detached oxidized/sulfonated oligomeric fragments and consequent poisoning of the latex sites. Ways to ameliorate this and/or to rejuvenate the columns are also described.
more »
« less
- Award ID(s):
- 2003324
- PAR ID:
- 10548282
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Journal of Separation Science
- Volume:
- 47
- Issue:
- 19
- ISSN:
- 1615-9306
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Bacterial extracellular vesicles (BEVs), including outer membrane vesicles, have emerged as a promising new class of vaccines and therapeutics to treat cancer and inflammatory diseases, among other applications. However, clinical translation of BEVs is hindered by a current lack of scalable and efficient purification methods. Here, we address downstream BEV biomanufacturing limitations by developing a method for orthogonal size‐ and charge‐based BEV enrichment using tangential flow filtration (TFF) in tandem with high performance anion exchange chromatography (HPAEC). The data show that size‐based separation coisolated protein contaminants, whereas size‐based TFF with charged‐based HPAEC dramatically improved purity of BEVs produced by probiotic Gram‐negativeEscherichia coliand Gram‐positive lactic acid bacteria (LAB).Escherichia coliBEV purity was quantified using established biochemical markers while improved LAB BEV purity was assessed via observed potentiation of anti‐inflammatory bioactivity. Overall, this work establishes orthogonal TFF + HPAEC as a scalable and efficient method for BEV purification that holds promise for future large‐scale biomanufacturing of therapeutic BEV products.more » « less
-
Abstract Reported herein is a continuous one‐step melt extrusion approach for high‐density polyethylene (HDPE) vitrimers. A grafting agent and a coagent were used to produce high‐performing vitrimers. Maleic anhydride (MA) served as a reactive agent to facilitate crosslinking, while dimethyl maleate (DM) acted as a grafting enhancer by reducing the surface energy of HDPE grafted with MA. For comparison, MA alone was also tested as a grafting agent. The vitrimers obtained displayed superior mechanical properties compared with HDPE. The storage modulus, as well as crystallinity, were determined for the HDPE vitrimers. These vitrimers are reprocessable, thus supporting recycling efforts despite their crosslinked nature, owing to very fast relaxation due to low activation energy for the transesterification reaction. Consequently, these vitrimers are not only recyclable but also exhibit enhanced thermal and mechanical properties compared with conventional HDPE.more » « less
-
Abstract Polyethylene (PE) is the most widely produced synthetic polymer. By installing chemically cleavable bonds into the backbone of PE, it is possible to produce chemically deconstructable PE derivatives; to date, however, such designs have primarily relied on carbonyl‐ and olefin‐related functional groups. Bifunctional silyl ethers (BSEs; SiR2(OR′2)) could expand the functional scope of PE mimics as they possess strong Si−O bonds and facile chemical tunability. Here, we report BSE‐containing high‐density polyethylene (HDPE)‐like materials synthesized through a one‐pot catalytic ring‐opening metathesis polymerization (ROMP) and hydrogenation sequence. The crystallinity of these materials can be adjusted by varying the BSE concentration or the steric bulk of the Si‐substituents, providing handles to control thermomechanical properties. Two methods for chemical recycling of HDPE mimics are introduced, including a circular approach that leverages acid‐catalyzed Si−O bond exchange with 1‐propanol. Additionally, despite the fact that the starting HDPE mimics were synthesized by chain‐growth polymerization (ROMP), we show that it is possible to recover the molar mass and dispersity of recycled HDPE products using step‐growth Si−O bond formation or exchange, generating high molecular weight recycled HDPE products with mechanical properties similar to commercial HDPE.more » « less
-
The cycle time of a standard liquid chromatography (LC) system is the sum of the time for the chromatographic run and the autosampler injection sequence. Although LC separation times in the 1-10 s range have been demonstrated, injection sequences are commonly >15 s, limiting throughput possible with LC separations. Further, such separations are performed on relatively large bore columns requiring flow rates of ≥5 mL/min, thus generating large volumes of mobile phase waste when used for large scale screening and increasing the difficulty in interfacing to mass spectrometry. Here, a droplet injector system was established that replaces the autosampler with a four-port, two-position valve equipped with a 20 nL internal loop interfaced to a syringe pump and a three-axis positioner to withdraw sample droplets from a well plate. In the system, sample and immiscible fluid are pulled alternately from a well plate into a capillary and then through the injection valve. The valve is actuated when sample fills the loop to allow sequential injection of samples at high throughput. Capillary LC columns with 300 μm inner diameter were used to reduce the consumption of mobile phase and sample. The system achieved 96 separations of 20 nL droplet samples containing 3 components in as little as 8.1 min with 5-s cycle time. This system was coupled to a mass spectrometer through an electrospray ionization source for high-throughput chemical reaction screening.more » « less
An official website of the United States government