skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: State-of-the-art review of athletic wearable technology: What 113 strength and conditioning coaches and athletic trainers from the USA said about technology in sports
Wearables are a multi-billion-dollar business with more growth expected. Wearable technology is fully entrenched at multiple levels of athletic competition, especially at the National Collegiate Athletic Association (NCAA) and professional levels where these solutions are used to gain competitive advantages by assessing health and performance of elite athletes. However, through the National Science Foundation (NSF) Innovation Corps (I-Corps) training experience, a different story emerged based on pilot interviews from coaches and trainers regarding the lack of trust in wearables, and how the technology falls short of measuring what practitioners need. An NSF I-Corps project was funded to interview over 100 strength and conditioning coaches (S&CCs) and athletic trainers (ATs) regarding the current state of wearables at the NCAA and professional levels. Through 113 unstructured interviews, a conceptual map of relationships amongst themes and sub-themes regarding wearable technology emerged through the grouping of responses into meaning units (MUs). Interview findings revealed that discussions by S&CCs and ATs regarding wearables could be grouped into themes tied to (a) the organizational environment, (b) the athlete, and (c) the analyst or data scientist. Through this project, key findings and lessons learned were aggregated into sub-themes including: the sports ecosystem and organizational structure, brand development, recruiting, compliance and gamification of athletes, baselining movement and injury mitigation, internal and external loads, “return tos,” and quantifying performance. These findings can be used by practitioners to understand general technology practices and where to close the gap between what is available versus what is needed.  more » « less
Award ID(s):
1827652
PAR ID:
10549238
Author(s) / Creator(s):
 ;  ;  ;  ;  
Publisher / Repository:
SAGE Publications
Date Published:
Journal Name:
International Journal of Sports Science & Coaching
Volume:
15
Issue:
1
ISSN:
1747-9541
Format(s):
Medium: X Size: p. 26-40
Size(s):
p. 26-40
Sponsoring Org:
National Science Foundation
More Like this
  1. Context Temporal prediction of lower extremity (LE) injury risk will benefit clinicians by allowing them to better leverage limited resources and target athletes most at risk. Objective To characterize instantaneous risk of LE injury by demographic factors sex, sport, body mass index (BMI), and previous injury history. Instantaneous injury risk was defined as injury risk at any given point in time following baseline measurement. Design Descriptive epidemiology study. Setting NCAA Division I athletic program. Patients or Other Participants 278 NCAA Division I varsity student-athletes (119 males, 159 females). Main Outcome Measure(s) LE injuries were tracked for 237±235 days. Sex-stratified univariate Cox regression models investigated the association between time to first LE injury and BMI, sport, and previous LE injury history. Relative risk ratios and Kaplan-Meier curves were generated. Variables identified in the univariate analysis were included in a multivariate Cox regression model. Results Females displayed similar instantaneous LE injury risk compared to males (HR=1.29, 95%CI=[0.91,1.83], p=0.16). Overweight athletes (BMI>25 kg/m2) had similar instantaneous LE injury risk compared with athletes with BMI<25 kg/m2 (HR=1.23, 95%CI=[0.84,1.82], p=0.29). Athletes with previous LE injuries were not more likely to sustain subsequent LE injury than athletes with no previous injury (HR=1.09, 95%CI=[0.76,1.54], p=0.64). Basketball (HR=3.12, 95%CI=[1.51,6.44], p=0.002) and soccer (HR=2.78, 95%CI=[1.46,5.31], p=0.002) athletes had higher risk of LE injury than cross-country athletes. In the multivariate model, females were at greater LE injury risk than males (HR=1.55, 95%CI=[1.00,2.39], p=0.05), and males with BMI>25 kg/m2 were at greater risk than all other athletes (HR=0.44, 95%CI=[0.19,1.00], p=0.05). Conclusions In a collegiate athletic population, previous LE injury history was not a significant contributor to risk of future LE injury, while being female or being male with BMI>25 kg/m2 resulted in increased risk of LE injury. Clinicians can use these data to extrapolate LE injury risk occurrence to specific populations. 
    more » « less
  2. This NSF funded research study is developing a greater theoretical understanding of the professional identity, institutional culture, and formation of engineer technicians and technologists who are prepared at two-year colleges. The study is identifying dimensions of career anchors orientations at various stages of professional preparation and map to engineering technology (ET) career pathways by surveying ET students, transfer students, and early career ET professionals. The complexity of integration of the multiple stages of professional preparation, within diverse environments, has led the researchers to integrate three interdisciplinary theoretical frameworks to examine fundamental questions of professional formation: (1) social cognitive career theory to situate individual attitudes, interests, and experiences within a larger career context; (2) Schein’s Career Anchors Theory focused on individual career orientations; and (3) the Hughes Value Creation Model for Organizational Competitive Advantage focused on cultural and organizational contexts. Initial results from the Schein’s Career Anchor survey for the two-year college ET students are presented. Findings from this and future work will transform the ET workforce through catalyzing interaction of researchers and practitioners with public support to bolster ET’s strategic position in the workforce development infrastructure. 
    more » « less
  3. Background Mobile health (mHealth) wearable devices are increasingly being adopted by individuals to help manage and monitor physiological signals. However, the current state of wearables does not consider the needs of racially minoritized low–socioeconomic status (SES) communities regarding usability, accessibility, and price. This is a critical issue that necessitates immediate attention and resolution. Objective This study’s aims were 3-fold, to (1) understand how members of minoritized low-SES communities perceive current mHealth wearable devices, (2) identify the barriers and facilitators toward adoption, and (3) articulate design requirements for future wearable devices to enable equitable access for these communities. Methods We performed semistructured interviews with low-SES Hispanic or Latine adults (N=19) from 2 metropolitan cities in the Midwest and West Coast of the United States. Participants were asked questions about how they perceive wearables, what are the current benefits and barriers toward use, and what features they would like to see in future wearable devices. Common themes were identified and analyzed through an exploratory qualitative approach. Results Through qualitative analysis, we identified 4 main themes. Participants’ perceptions of wearable devices were strongly influenced by their COVID-19 experiences. Hence, the first theme was related to the impact of COVID-19 on the community, and how this resulted in a significant increase in interest in wearables. The second theme highlights the challenges faced in obtaining adequate health resources and how this further motivated participants’ interest in health wearables. The third theme focuses on a general distrust in health care infrastructure and systems and how these challenges are motivating a need for wearables. Lastly, participants emphasized the pressing need for community-driven design of wearable technologies. Conclusions The findings from this study reveal that participants from underserved communities are showing emerging interest in using health wearables due to the COVID-19 pandemic and health care access issues. Yet, the needs of these individuals have been excluded from the design and development of current devices. 
    more » « less
  4. Ethics as embodied by technology practitioners resists simple definition—particularly as it relates to the interplay of identity, organizational, and professional complexity. In this paper we use the linguistic notion of languaging as an analytic lens to describe how technology and design practitioners negotiate their conception of ethics as they reflect upon their everyday work. We engaged twelve practitioners in individual co-creation workshops, encouraging them to reflect on their ethical role in their everyday work through a series of generative and evaluative activities. We analyzed these data to identify how each practitioner reasoned about ethics through language and artifacts, finding that practitioners used a range of rhetorical tropes to describe their ethical commitments and beliefs in ways that were complex and sometimes contradictory. Across three cases, we describe how ethics was negotiated through language across three key zones of ecological emergence: the practitioner’s “core” beliefs about ethics, internal and external ecological elements that shaped or mediated these core beliefs, and the ultimate boundaries they reported refusing to cross. Building on these findings, we describe how the languaging of ethics reveals opportunities to definitionally and practically engage with ethics in technology ethics research, practice, and education. 
    more » « less
  5. High testosterone is associated with increased physical performance in sports due to its stimulation with body-muscle ratio, lean mass (muscle and bone), and bone density. Several studies show athletes with better explosive strength and sprint running performances in football, have a higher basal level of testosterone. The results suggest a relationship between testosterone production and the development of fast-twitch muscle fibers, endurance training, lean mass, resistance training in athletes as well as motivation for competition. Thus, monitoring testosterone levels is gaining attention to evaluate athletic performance of one's physical performance in sport, fitness, and bodybuilding as well as prevent health risk factors for low levels of testosterone. There have been attempts using optical, electrical and biochemical sensors to monitor testosterone but are difficult to reproduce in large quantities and suffer from limitations of sensitivity, and detection limits. This can be addressed using Molecularly Imprinted Polymers (MIPs) in a point of care (POC) system. Molecularly Imprinted Polymers (MIPs) are a synthetic polymer with cavities in the polymer matrix serve as recognition sites for a specific template molecule, which are detected using electrochemical amperometry. In this paper, we have used MIPs in conjunction with cyclic voltammetry, to produce a viable, ultrasensitive electrochemical sensor for the detection of testosterone from a human sweat sample. This combination of MIPs and cyclic voltammetry allows for a simple, low-cost, mass-producible, and non-invasive method for detecting testosterone in human males. This method is extremely simple and cheap, allowing for consistent measurement of Testosterone levels in humans and allows for the detection of Testosterone in a POC. In our work, a Screen-printed carbon electrode (SPCE) using polypropylene fabric was used as the base working electrode in a three-electrode system. The screen-printing technique was implemented to layer a carbon paste over both sides of the fabric and was air-dried for one hour at 75⁰C. The SPCE was immersed into an acetate buffer solution that contains a 2.0mM monomer called o-phenylenediamine and with a 0.1mM testosterone template. Electropolymerization was carried out with cyclic voltammetry from a range of 0V to 1.0V, at a scan rate of 50 mV/s, a sensitivity (A/V) of 1e-5A, and for a total of 30 cycles. The set concentration tested was 100-1600 ng/ml of testosterone. The electrochemical characterization will have a potential sweep of -1.2 V to 1.2 V, a scan rate of 0.05 (V/s), a sensitivity (A/V) of 1e-5A, and a singular cycle. The wearable biosensor showed a detection range for testosterone from 100ng to 1600ng, electrochemical results also showed a clear and measurable result with an R-square value of 0.9417 which proves the accuracy of the developed sensor. Although this is not the complete saturation point and theoretically maximum limit of 28,842ng/ml can be achieved although this was not tested. The detectable lowest concentration of testosterone was found to be ~100ng/ml, and it was noted that lower than 100ng gives a weaker signal, In conclusion a novel electrochemical sensor based on a molecularly imprinted polymer used as the extended gate of a field effect transistor was developed for the ultrasensitive detection of sweat Testosterone. This sensing technology paves the way for the low cost, label-free, and point of care detection which can be used for evaluating ang monitoring athletic performance. 
    more » « less