			<titleStmt><title level='a'>Reliability Groups with Standby Flying Light Specks</title></titleStmt>
			<publicationStmt>
				<publisher>ACM</publisher>
				<date>04/15/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10552383</idno>
					<idno type="doi">10.1145/3625468.3647606</idno>
					
					<author>Hamed Alimohammadzadeh</author><author>Shuqin Zhu</author><author>Jiadong Bai</author><author>Shahram Ghandeharizadeh</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[A Flying Light Speck, FLS, is a miniature sized drone configured with light sources to illuminate different colors and textures. A swarm of FLSs illuminates complex 3D multimedia shapes in a fixed volume, a 3D display. An FLS is a mechanical device. Its failure is the norm rather than an exception, causing a point of an illumination to go dark. In this paper, we use reliability groups with dark standby FLSs to minimize the duration of time a point remains dark. This study makes two novel contributions. First, it compares a centralized and a decentralized algorithm to form groups, demonstrating the superiority of the centralized technique. Second, it detects when the dark standby FLSs may obstruct the user's field of view and relocates them with minimal impact on their provided benefit.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><p>Figure <ref type="figure">4</ref>: The yellow cylinders of the simple architecture <ref type="bibr">[18]</ref> are dispatchers that deploy FLSs. A dispatcher deploys FLSs at a rate and a display consists of dispatchers. Failed FLSs fall on a conveyor belt that deposits them in a Terminus. the user's FoV, and how a standby changes its location to not obstruct the user's FoV. These novel contributions are absent from the aforementioned studies.</p><p>The concept of reliability groups <ref type="bibr">[14,</ref><ref type="bibr">15,</ref><ref type="bibr">30,</ref><ref type="bibr">31]</ref> and standbys dates back to arrays of memory modules and disks <ref type="bibr">[20,</ref><ref type="bibr">29]</ref>. With disk subsystems such as RAID <ref type="bibr">[26]</ref>, the hardware infrastructure dictates the characteristics of the reliability groups. FLS displays are different in that the data in the form of a point cloud dictates the characteristics of the reliability groups. Distance between the points that constitute a reliability group is an important consideration as it dictates MTID and QoI. This concept is absent from prior literature in the area of high data availability. Another difference is that, an FLS display may use reliability groups selectivity to enhance MTID. As detailed in Section 5, a simple priority queue enables an FLS display to not deploy standby FLSs, disabling the concept of a reliability group when it is not beneficial. Hardware and software RAIDs do not require this flexibility. Finally, data availability techniques do not have the concept of a standby obstructing a user's FoV. This important consideration is addressed in this paper.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3">TERMINOLOGY AND PROBLEM STATEMENT</head><p>We assume the architectures of <ref type="bibr">[2,</ref><ref type="bibr">18]</ref> consisting of a hub and one or more dispatchers to deploy FLSs. See Figure <ref type="figure">4</ref>. The hub is comparable to today's server. It hosts an Orchestrator process that communicates with FLSs using wireless communication, detects failures, and coordinates the dispatchers to deploy FLSs. A dispatcher may be in the form of a cylinder on the sides of a display 3 <ref type="bibr">[18]</ref>. The rate at which an architecture deploys FLSs impacts MTID.</p><p>Display cell and illumination cell are fundamental to this study. To render an illumination, an FLS display constructs a 3D mesh on the display volume. A cell of this mesh, a display cell <ref type="bibr">[18]</ref>, is dictated by the downwash of an FLS <ref type="bibr">[7,</ref><ref type="bibr">8,</ref><ref type="bibr">16,</ref><ref type="bibr">28,</ref><ref type="bibr">35]</ref>. Assuming an FLS is a quadrotor, a cell may be an ellipsoid <ref type="bibr">[7,</ref><ref type="bibr">8,</ref><ref type="bibr">28]</ref> or a cylinders <ref type="bibr">[16,</ref><ref type="bibr">35]</ref> that results in a larger separation along the height 3 Or black tiles at the bottom of a Dronevision <ref type="bibr">[2]</ref>.</p><p>dimension. Each display cell has a unique Length, Height, and Depth (L,H,D) coordinate <ref type="bibr">[18]</ref>. We use the L, H, D coordinate system instead of X, Y, Z to identify a cell because there is no consensus on one definition of the Y and Z axes. While the picture industry uses the Z axis as the depth, mathematicians use the Y axis for the depth. It is trivial to map our L, H, D coordinate system to either definition without ambiguity.</p><p>The light emitted from an FLS fills an illumination cell. We assume an illumination cell is either the same size or larger than a display cell. Without loss of generality and to simplify the discussion, we assume a display cell and an illumination cell are cubes. We denote the ratio of an illumination cell to a display cell along a dimension as Q. Assuming the same Q value across L, H, and D, the number of display cells contained in an illumination cell is Q 3 . A maximum of Q 3 FLSs may occupy different cells of an illumination cell with one FLS illuminating the cell. We assume the remaining Q 3 -1 FLSs remain invisible. This assumption is reasonable because these FLSs may render the same light and color as the illuminating FLS with lower intensity depending on the location of their occupied display cell.</p><p>An increase in the value of Q may be interpreted in different ways. One interpretation is that the display is increasing in size and the light source of each FLS is bright enough to illuminate an increasing number of display cells. For example, with Q=10, an FLS must illuminate 100 displays cells and the display is 10x larger along a dimension when compared with Q=1. The second interpretation is that the volume of downwash by an FLS has shrunk. Q=10 implies this volume shrunk 10x when compared with Q=1, enabling the display to construct a larger number of FLSs in an illumination cell. In this paper, we assume the first interpretation of Q. It is trivial to convert the results of this paper in the context of the second interpretation <ref type="foot">4</ref> . Definition 1. Quality of Illumination (QoI) of a point cloud is the percentage of its points illuminated by FLSs at an instance in time.</p><p>The best theoretical QoI value is 100%. The QoI of a rendering may be lower than 100% due to failure of the illuminating FLSs. The tolerable QoI is application dependent.</p><p>We use Mean Time To Failure (MTTF) <ref type="bibr">[18,</ref><ref type="bibr">26,</ref><ref type="bibr">29]</ref>, to quantify the average amount of time an FLS operates before it fails. A higher MTTF is desirable because it reflects a longer FLS lifespan. We construct reliability groups consisting of illuminating FLSs and standby FLSs. A standby is a dark FLS assigned to a group of illuminating FLSs. The distance between the FLSs should be minimized to enable the standby to substitute for a failed FLS as fast as possible, minimizing the MTID. Definition 2. Mean Time to Illuminate a Dark point (MTID) is the average elapsed time from when a point of a point cloud goes dark due to the failure of its illuminating FLS and back to being illuminated by a replacement FLS. Definition 3. A group centroid is the coordinate that identifies the center of a reliability group consisting of FLSs. It is computed using the coordinates of its FLSs:</p><p>], where [ , , ] is the coordinate of the &#8462; FLS in the group. The Orchestrator assigns a standby to the group centroid as long as it is not occupied by an illuminating FLS, i.e., the coordinates of a point in a point cloud.</p><p>Problem Definition 1. Minimize the MTID of an illumination given reliability groups with illuminating FLSs and standby FLS without obstructing the user's FoV.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1">Failure types</head><p>We assume FLS failures are either mechanical, lighting related, or both. These prevent an FLS from either flying, rendering its illumination responsibilities, or both. In addition, we assume an FLS may detect these failures and use its wireless communication interface to notify its neighboring FLSs and the Orchestrator of its failure. We defer failure of electronics that prevent an FLSs from communicating to future work.</p><p>When an illuminating FLS fails, its assigned point (coordinate) goes dark. The display may illuminate this point by either requiring a dispatcher to deploy a new FLS to the coordinates of the dark point or use a nearby standby to fly to the coordinates of the dark point (failed FLS) to resume its lighting responsibilities. The latter minimizes MTID, motivating reliability groups with standby FLSs per group.</p><p>With reliability groups, we assume an illuminating and a standby FLS are identical with the same MTTF. A reliability group may be in either the normal or a degraded mode of operation. In the normal mode, the group consists of illuminating FLSs and standbys. In degraded mode, either one or more illuminating FLSs have failed, one or more standby FLSs have failed or are missing (because they substituted for a failed illuminating FLS), or a combination of these possibilities.</p><p>When an illuminating FLS fails, it notifies its group members and the Orchestrator of its failure. Its message identifies the group that experienced the failure, . If has an idle standby FLS, this FLS changes its status to illuminating and flies to the coordinate of the failed FLS to assume its lighting responsibility. The Orchestrator dispatches a new standby to . The coordinates of this standby is 's centroid. When a standby FLS fails, it notifies the illuminating FLSs and the -1 standbys in its group and the Orchestrator of its failure. The illuminating FLSs maintain the absence of a standby and switch to degraded mode of operation. The Orchestrator dispatches a new FLSs to the coordinates identified by the group centroid as the replacement standby. In case the replacement standby fails mid-flight, it notifies the Orchestrator to deploy a new replacement FLS. Once a replacement standby is dispatched, it notifies the illuminating FLSs in its group of its presence. The illuminating FLSs record the presence of the standby and switch to normal mode of operation.</p><p>If has no standby FLS and one of its illuminating FLSs fails, either the Orchestrator or the failed FLS may notify a mid-flight replacement standby for the group to change its destination to the coordinates of the failed illuminating FLS and resume its lighting responsibility. In essence, this mid-flight standby becomes an illuminating FLS on its way to illuminate its assigned point. Next, the Orchestrator deploys a new standby for . The coordinates of this standby is 's group centroid.</p><p>With FLS failures, the number of dispatchers and the rate at which they deploy FLSs are important factors. With fully utilized dispatchers, standby FLSs may degrade both QoI and MTID. This is because standby FLSs fail similar to illuminating FLSs. Deployment of standby FLSs taxes the dispatchers and prevents them from deploying FLSs to illuminate points that improve QoI/MTID. Below, we formalize these concepts and highlight their interrelationships. Failure Model: We assume a simple failure model with FLSs failing independent of one another. This model selects a time to live (TTL) between 1 second and a fixed constant . The life time of an FLS may not exceed , TTL &#8804; . Once this TTL expires, an FLS fails. The distribution used to select a TTL impacts QoI. We considered several distributions for a model. Due to lack of space, we present the model using a uniform distribution. With this model, an FLS selects a random value between 1 and and approximates a mean of the distribution close to 2 .</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4">GROUP CONSTRUCTION</head><p>Problem Definition 2. Given a point cloud with points (coordinates) with each point assigned to a different FLS and a required group size , maximize the number of groups consisting of approximately FLSs such that (1) an FLS participates in exclusively one group and all FLSs agree on participation in the same group, and (2) the euclidean distance between the group members is minimized.</p><p>In this paper, the symmetry constraint that all FLSs in a group agree to be a member of the same group is fundamental. We focus on a popular centralized group formation technique named -means <ref type="bibr">[22]</ref> and a decentralized technique named Closest Available Neighbor First, CANF <ref type="bibr">[3]</ref>. With both, the number of groups is bounded by &#8968; &#8969;. At the same time, the two techniques are different. While -means constructs groups consisting of a variable number of illuminating FLSs, CANF constructs groups each with FLSs<ref type="foot">foot_1</ref> .</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.1">Centralized Group Construction: -Means</head><p>With a centralized technique, the Orchestrator processes a point cloud to compute groups and the location of each of the standbys for each group. It uses k-means <ref type="bibr">[22]</ref>, a clustering technique that partitions a point cloud with points into groups defined by a centroid. Given the size of a reliability group , is defined as</p><p>-means is an iterative heuristic that adjusts the new centroid locations in each iteration. The first iteration selects the centroids randomly <ref type="bibr">[6]</ref>. Each subsequent iteration computes point-to-cluster distance for each centroid by iterating the points in the point cloud. It uses the average of these distances to compute new centroid locations. It repeats until either the cluster assignment does not change or a maximum number of iterations (1000) is reached <ref type="foot">6</ref> . The iterative portion of this implementation consists of two passes: batch and online. During batch updates, each iteration re-assigns points to their nearest cluster centroid followed by re-computation of cluster centroids. During the online</p></div>			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="4" xml:id="foot_0"><p>The acceleration and deceleration components of the velocity model may impact the conversion of the results between the two interpretations.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="5" xml:id="foot_1"><p>One group is an exception when is not an integer.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="6" xml:id="foot_2"><p>The geometry of a point cloud and the value of dictates how quickly k-means constructs groups. In our experiments with the point clouds of Figure1, the number of passes with =3 (20) and the dragon, hat, and skatebaord is 6, 6, 4<ref type="bibr">(13,</ref><ref type="bibr">14,</ref><ref type="bibr">20)</ref>, respectively.</p></note>