<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>A Deep Learning Approach for High-Accuracy Radiometer Calibration Using SMAP Satellite Data</title></titleStmt>
			<publicationStmt>
				<publisher>IEEE</publisher>
				<date>07/07/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10563018</idno>
					<idno type="doi">10.1109/IGARSS53475.2024.10640563</idno>
					
					<author>A M Alam</author><author>M Kurum</author><author>M Ogut</author><author>A C Gurbuz</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Radiometers play a crucial role in providing accurate geophysical information, relying heavily on precise calibration for both radiometric accuracy and spectral consistency. Radiometers consistently allocate time and hardware resources to calibration, resources that could otherwise be utilized for environmental sensing. In addition, calibration faces challenges such as frequency dependence and environmental influences, requiring to the need for innovative solutions. In this study, advancements in deep learning (DL) techniques are utilized, using NASA's Soil Moisture Active Passive (SMAP) satellite data to create a DL-based radiometer calibrator. The use of 2-D spectral features as input in a convolutional neural network shows promising results with high correlation and low error. Notably, ancillary features like internal thermistor temperature prove accurate for estimating antenna temperature. This compensates for changes in receiver noise temperature and short-term gain fluctuations, even when there's no reference load or noise diode power. The proposed calibration technique, emphasizing reduced reference information, holds significant potential for a higher number of antenna scene observations within a footprint.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">INTRODUCTION</head><p>Microwave and millimeter-wave radiometry significantly contribute to our understanding of geophysical parameters, such as soil moisture, sea-surface wind, atmospheric water vapor and ocean salinity. These instruments play a vital role in diverse fields like hydrology and meteorology <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref>. Ensuring their accuracy and sensitivity is crucial for reliable parameter derivation. While accuracy impacts data reliability, sensitivity determines the smallest detectable change, accounting for internal noise. Microwave radiometers employ various calibration methods to ensure precise and reliable measurements of microwave radiation, enhancing the accuracy of collected data. These calibration techniques fall into two categories: external calibration and internal calibration <ref type="bibr">[4,</ref><ref type="bibr">5]</ref>. External calibration involves using references or targets in space to calibrate the radiometer's measurements, utilizing well-characterized radiometric properties of known targets as references for a voltageto-antenna temperature calibration line. However, challenges arise, including accessing stable calibration references, environmental variations, instrument stability within the calibration cycle, and correcting fast 1/f noise gain fluctuations. On the other hand, radiometer internal calibration incorporates noise injection and Dicke-switching reference loads. By rapidly switching between internal calibration sources, this technique effectively eliminates gain fluctuations caused by 1/f noise at the receiver output. However, uncertainties may be introduced in the calibration due to factors such as noise diode instability from thermal fluctuations and aging, as well as potential mismatches at the reference load. These factors can lead to errors or biases in the calibration, impacting the accuracy of radiometric measurements. This paper introduces a novel calibration approach based on deep learning (DL), leveraging 2-D time-frequency spectral features and reduced reference information from reference and noise sources to estimate antenna temperature <ref type="bibr">[6]</ref>. The application of convolutional neural network (CNN) based DL framework demonstrates promising potential in minimizing the need for frequent internal calibration, allowing for increased frequency in antenna temperature measurements. Post-launch, samples from vicarious sources or other calibration targets can be used to fine-tune the DL-based calibration during on-orbit operation. This adjustment is crucial in accommodating on-orbit effects and non-stationary instrument changes, such as aging and orbital variations. Data-driven calibration methods have been introduced first in this <ref type="bibr">[7,</ref><ref type="bibr">8]</ref>. This work is centered around using average voltage or antenna temperature. However, with radiometers transitioning to wideband sensing in unprotected regions, there's a growing emphasis on harnessing spectral information. Radiome-</p><p>Primary Input (a) Secondary Input (b) 1. 2 nd Raw Moments (I) 2. 2 nd Raw Moments (Q) 3. Radiometer Power in Ref. Load (I) 4. Radiometer Power in Ref. Load (Q) 5. Radiometer Power in Ref. Load and ND (I) 6. Radiometer Power in Ref. Load and ND (Q) 7. Antenna Temperature of the Reference Load 8. Antenna Temperature of ND 9. Phase Difference 1. Reflector Loss 2. Feed Horn Loss 3. Reflector Temperature 4. Feed Horn Temperature 5. OMT Temperature 6. CNS Temperature 7. Diplexer Temperature 8. Radome Temperature &#119917;&#119918; &#120783; &#119917;&#119918; &#120784; &#119917;&#119918; &#120785; &#119917;&#119918; &#120786; &#119917;&#119918; &#120787; ters capture 2-D time-frequency data, an aspect not directly tapped into by conventional calibration methods. This study introduces an innovative approach that incorporates these 2-D features, along with supplementary ancillary information, for calibration. The goal is to assess the robustness of this approach with reduced reference information, employing various validation strategies to understand the generalization capability of DL in estimating antenna temperature. Future studies will implement this DL-based calibrator in a softwaredefined radio (SDR)-based L-band radiometer <ref type="bibr">[9]</ref>.</p><p>The remainder of the paper is organized as follows: dataset utilized in this study is detailed in Section 2, while the methodology for DL-based calibration is in Section 3. Results and discussions are provided in Section 4 and finally, a conclusion is drawn in Section 5.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">DATASET</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1.">SMAP Level 1A Data</head><p>The SMAP level 1A data product includes antenna counts at both full-band and subband levels, with these counts being represented by various statistical raw moments <ref type="bibr">[10]</ref>. Among these moments, the second raw moments are particularly important as they serve as an equivalent measure of power. In our research, we focus on these second raw moments as the primary input for analysis. Fig. <ref type="figure">1a</ref> provides a list of features extracted from the level 1A data product, and our input features also encompass the measured counts of the reference load and the reference plus ND. These reference counts offer valuable information and are used alongside the raw antenna moments in our analysis. It's worth noting that all these moments are accessible in both the in-phase (I) and quadrature (Q) channels for both horizontal polarization (H-pol) and vertical polarization (V-pol). This comprehensive set of features forms the basis for our research investigation.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.">SMAP Level 1B Data</head><p>The level 1B data products include antenna temperature measurements, quality flags indicating data reliability, and details about various radiometer components' loss elements <ref type="bibr">[11,</ref><ref type="bibr">12]</ref>. Fig. <ref type="figure">1a</ref> and Fig. <ref type="figure">1b</ref> present these features. In our study, we use the antenna temperature values for both horizontal (Hpol) and vertical polarization (V-pol) as ground truth references. These values help us model the relationship between the measured input voltage and the resulting antenna temperature. To enhance calibration, we incorporate thermistor data from the reference load and ND physical temperature as input features for our model. Additionally, the model includes thermistor/physical temperature readings from different satellite components, such as the reflector, feed horn, orthomode transducer (OMT), and correlated noise source (CNS) during training. Crucial to radiometer calibration are the loss elements of various components, including reflector loss, feed horn loss, and phase imbalances, which are extracted from SMAP level 1B data products. For more in-depth information about these features, refer to the algorithm theoretical basis document of SMAP.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Data Preparation</head><p>The input features for the DL-based calibrator are categorized into primary and secondary groups. Primary inputs include 2-D time-frequency spectrograms fed directly into the convolutional layers of the DL model. Secondary inputs, divided into five feature groups (FGs), are integrated within the DL framework along with primary input features. The five FGs serve various roles in calibrating radiometers, accommodating scenarios with or without power information from the reference and ND. They include features related to the 2nd raw moments (FG1), power of the reference load (FG2), power of ND (FG3), internal physical temperature (FG4), and element losses and physical temperatures (FG5). Radiometer footprints are sequences of 12 packets, each lasting 1.2 ms. FG1 packets focus on observing the scene, while FG2 and FG3 packets are allocated for internal calibration. The data within each packet is divided into 16 subbands covering the SMAP radiometer band of 1400-1427 MHz. The primary inputs, represented by 2-D spectrograms, have a shape of 16 &#215; 8. An example antenna count spectrogram (Fig. <ref type="figure">1e</ref>) displays eight antenna measurements and 16 subbands within a particular footprint. To maintain a consistent matrix size for the DL model, observations are broadcasted into 16 &#215; 8, involving the extension of the same reference packet for four consecutive packets in a specific subband.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Training Scenarios</head><p>In the previous section, we discussed how input features are categorized into five Functional Groups (FGs) for radiometer calibration. These FGs play a crucial role in creating different training schemes for DL-based frameworks, each aimed at determining the optimal amount of voltage or power information needed from the reference unit to accurately estimate antenna temperature. In these cases, FG 2 and FG 3 represent using only the 5th and 6th time packet observation of FG 2 and FG 3 . These schemes are illustrated in Fig. <ref type="figure">2</ref>. Case 1 aligns with conventional radiometer calibration using the same input features. While a direct comparison with conventional approaches is beyond our study scope, future research will explore applying this calibration method to airborne Lband radiometers for performance comparison. Case 2 uses information from ND without matched reference load information, while Case 3 does the opposite. Case 4 involves using one packet of reference and ND information, unlike conventional calibration requiring two packets per radiometer footprint. Case 5 uses no power information from the reference load and ND. Throughout the training process, FG 1 , FG 4 , and FG 5 are always incorporated, with FG 4 containing the physical temperature feature of the reference and ND. Our findings suggest that thermistor temperature and loss elements exhibit sufficient stability to compensate for variations in receiver noise temperature and short-term gain fluctuations in the absence of reference load and ND power.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">METHODOLOGY 3.1. DL-Based Framework for Calibration</head><p>The DL framework, depicted in Fig. <ref type="figure">3</ref>, comprises convolutional layers for extracting features from n-channel spectrograms, concatenation layers to combine these features with secondary inputs, and densely connected layers for mapping the combined features to radiometer antenna temperature. The primary input is 2-D spectrograms containing data about observation, reference, ND, and phases. To assess the model's flexibility, it's trained and tested under five different scenarios, demonstrating its superiority over conventional forward 16 &#215; 8 &#215; &#119899; n-channel spectrogram n = 9 (Case 1) n=7 (Case 2, 3, and 4) n = 5 (Case 5) Flattening Dense (128 &#215; 5 + 8) + Concatenation Conv1 Filters = 32 Kernel = 3 &#215; 3 + ReLU Batch Normalization Conv2 Filters = 64 Kernel = 3 &#215; 3 + ReLU Batch Normalization Conv3 Filters = 128 Kernel = 3 &#215; 3 + ReLU Batch Normalization Maxpool Kernel =2 &#215; 2 Dense (256) Dense (64) Primary Input Secondary Input Dense (128) Dense (1) Predicted Antenna Temperature 14 &#215; 6 &#215; 32 12 &#215; 4 &#215; 64 10 &#215; 2 &#215; 128 5 &#215; 1 &#215; 128 FC FC FC FC Fig. 3. Deep learning architecture to predict antenna temperature [6]. 4. RESULTS AND DISCUSSION 4.1. Overall Performance Two validation techniques, train-test split and K-fold, are utilized with a dataset comprising land and land-water samples. Table <ref type="table">1</ref> summarizes the overall performance in various trainingtesting scenarios for both land and land-water mixtures. In the train-test split, Case 1 excels with the lowest RMSE values (0.24 K for land, 0.29 K for land-water) and high R 2 values (0.9998 and 0.9997), underlining DL's efficacy with features comparable to conventional radiometers. Case 2, excluding power information, maintains impressive performance (RMSE 0.42 for land, 0.40 for land-water), showcasing DL's ability with minimal reference data. Case 3, incorporating reference plus ND power, outperforms Case 2. Case 4, using a single packet of power information, surpasses Cases 2 and 3. Despite Case 5's decline without reference and ND power, the DL calibrator maintains RMSE (0.67 K land, 0.45 K landwater) below SMAP radiometer uncertainty (1.3K). Training with land-water mix data yields lower RMSE, indicating diverse features. K-fold validation aligns with train-test split, confirming DL's resilience. Case 1 excels, while Cases 2-5 with reduced reference data exhibit low RMSE and high R 2 , catering to specific radiometer needs.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.2.">Computational Complexity</head><p>This study introduces a DL framework for predicting SMAP radiometer antenna temperature, considering diverse spatial and temporal data distributions. The quantitative analysis focuses on determining the required amount of data for prediction. Fig. <ref type="figure">4</ref> illustrates RMSE performance for varying training sizes across five cases, with a fixed SMAP radiometer uncertainty line at 1.3 K. Generally, RMSE decreases with larger training sizes. Notably, Cases 1 and 4 achieve acceptable RMSE with only 25% of the training dataset, while Cases 2 and 3 require around 40%. Case 5 needs approximately 60%. Cases 1 and 4 benefit from power features, aiding quick convergence, while Cases 2 and 3, with less reference information, demand more training samples. Overall, the DLbased calibrator demonstrates satisfactory performance even with reduced reference information and training data.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.">CONCLUSION</head><p>This research highlights the effectiveness of calibrating radiometers through the use of DL techniques. It takes advantage of limited reference information and organizes twodimensional antenna counts into time and frequency sub-bands. This DL-based calibrator will play a vital role in a future endto-end data-driven microwave radiometer setup. It will be  integrating seamlessly into a framework that includes a preexisting unit for detecting and mitigating radio frequency interference <ref type="bibr">[13]</ref><ref type="bibr">[14]</ref><ref type="bibr">[15]</ref>.</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>Authorized licensed use limited to: Mississippi State University Libraries. Downloaded on December 30,2024 at 19:11:28 UTC from IEEE Xplore. Restrictions apply.</p></note>
		</body>
		</text>
</TEI>
