<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Fabrication and Processing of Magnesium-Based Metal Matrix Nanocomposites for Bioabsorbable Implants</title></titleStmt>
			<publicationStmt>
				<publisher>MDPI</publisher>
				<date>11/22/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10567899</idno>
					<idno type="doi">10.3390/met14121318</idno>
					<title level='j'>Metals</title>
<idno>2075-4701</idno>
<biblScope unit="volume">14</biblScope>
<biblScope unit="issue">12</biblScope>					

					<author>Andres Larraza</author><author>Shane Burke</author><author>Pedram Sotoudehbagha</author><author>Mehdi Razavi</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[A novel magnesium (Mg)-based metal matrix nanocomposite (MMNC) was fabricated using ultrasonic melt treatment to promote the de-agglomeration of the bioactive glass–ceramic nanoparticles and the homogenization of the melt. The cast samples were then heat treated, machined, and hot rolled to reduce grain size and remove structural defects. Standard mechanical and electrochemical tests were conducted to determine the effect of fabrication and processing on the mechanical and corrosion properties of MMNCs. Compression tests, potentiodynamic polarization tests, electrochemical impedance spectroscopy, and static immersion testing were conducted to determine the characteristics of the MMNCs. The results showed that the combination of ultrasonic melt processing and thermomechanical processing caused the corrosion rate to increase from 8.7 mmpy after 10 days of immersion to 22.25 mmpy when compared with the ultrasonicated MMNCs but remained stable throughout the immersion time, showing no statistically significant change during the incubation periods. These samples also experienced increased yield stress (135.5 MPa) and decreased elongation at break (21.92%) due to the significant amount of grain refinement compared to the ultrasonicated MMNC (σY = 59.6 MPa, elongation = 40.44%). The MMNCs that underwent ultrasonic melt treatment also exhibited significant differences in the corrosion rate calculated from immersion tests.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">Introduction</head><p>Metal implants are predominantly used for bone-fixing devices due to their high mechanical properties <ref type="bibr">[1,</ref><ref type="bibr">2]</ref>. Common alloys consist mainly of bioinert permanent materials like titanium alloys (Ti-6Al-4V) and stainless steels. These metals provide mechanical rigidity and chemical stability, which the bone needs to heal properly <ref type="bibr">[3&#177;6]</ref>. However, since these metals do not degrade over time, revisionary surgeries to remove the implants when the wound is fully healed are often necessary. Similarly, the release of metallic particles and ions from the surfaces poses a risk of adverse effects <ref type="bibr">[7,</ref><ref type="bibr">8]</ref>. To combat these risks, developing a biocompatible, biodegradable metal can eliminate the need for revisionary surgery and overcome limitations associated with permanent implants <ref type="bibr">[9]</ref>.</p><p>Magnesium has shown significant potential in biodegradable implant applications due to its high biocompatibility; however, its potential is hindered by rapid corrosion rates and the generation of hydrogen gas as a corrosion byproduct <ref type="bibr">[2,</ref><ref type="bibr">7]</ref>. Efforts to improve corrosion resistance through alloying and surface coating have yielded significant advances, but these enhancements often compromise biocompatibility [10&#177;12]. WE43 is a commercially available biocompatible magnesium alloy that utilizes rare earth metals to reduce corrosion, rendering it nearly bioinert. Recent research is focused on fine-tuning corrosion resistance while maintaining biodegradability and enhancing osteogenic and angiogenic properties <ref type="bibr">[13]</ref>. The addition of scandium (Sc) and strontium (Sr) has been shown to provide corrosion resistance in vitro while also providing biocompatible environments for osteoblast differentiation and offering antibacterial properties <ref type="bibr">[14,</ref><ref type="bibr">15]</ref>.</p><p>Current methods for fabricating magnesium alloys or composites typically involve either stir casting or powder metallurgy. In stir casting, an impeller is submerged into the molten material and rotated at high speeds to promote thorough mixing. Alternatively, powder metallurgy involves milling raw materials into fine powders, compacting them, and then sintering to achieve the desired density and porosity. A major drawback of stir casting is the introduction of gas bubbles into the melt, which leads to porosity during solidification <ref type="bibr">[16&#177;18]</ref>. This results in reduced mechanical strength and corrosion resistance, issues that are challenging to address within the casting process itself. In powder metallurgy, porosity is reduced by sintering the compacted sample, typically under high temperatures and pressures. This process increases sample density; however, achieving zero porosity remains challenging <ref type="bibr">[19]</ref>.</p><p>The application of melt processing techniques, such as ultrasound treatment, enhances the de-agglomeration and dispersion of additive particles, influences the grain morphology of as-cast materials, and eliminates structural defects like porosity and non-uniformities <ref type="bibr">[19&#177;21]</ref>. The stimulation of the melt with acoustic waves induces acoustic streaming, a phenomenon where the fluid solution moves in a regular oscillatory motion, which can result in cavitation of gas bubbles and de-agglomeration of reinforcing nanoparticles in the melt <ref type="bibr">[22,</ref><ref type="bibr">23]</ref>. Postmelt processing via hot rolling also significantly affects the grain structure, which in turn affects the mechanical properties and corrosion behavior of the metals <ref type="bibr">[24,</ref><ref type="bibr">25]</ref>.</p><p>Although the individual alloying of magnesium with strontium (Sr) and scandium (Sc) has been studied for improvements in corrosion resistance, mechanical properties, and biocompatibility [26&#177;29], the synergistic potential of these elements in a ternary Mg-Sr-Sc alloy system remains largely unexplored. Moreover, to our knowledge, no substantial studies have investigated the integration of this alloy with bioactive glass&#177;ceramic nanoparticles. By developing this novel composite, we aim to harness the complementary benefits of Sr and Sc alloying together with bioactive glass&#177;ceramic reinforcement, creating a multifunctional implant material that meets both the structural and biological demands of bone regeneration.</p><p>Incorporating diopside (CaMgSi 2 O 6 ) bioactive glass&#177;ceramic nanoparticles (BG) into a magnesium-based metal matrix nanocomposite (MMNC) offers significant potential benefits for implant biocompatibility and bioactivity. The sustained release of calcium, magnesium, and silicon ions from these nanoparticles can enhance osteogenesis and angiogenesis and improve biocompatibility <ref type="bibr">[30&#177;32]</ref>.</p><p>In this study, we fabricated a novel MMNC by incorporating Sc and Sr as alloying elements and BG as nano-reinforcements using ultrasonic melt treatment, followed by a hot rolling process. We aim to understand the effects of ultrasonic melt processing and rolling on the microstructure, as well as the mechanical properties and corrosion resistance. The results were compared with those of magnesium, unprocessed MMNCs, and WE43, a commercial biocompatible magnesium-based alloy, as a control.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">Materials and Methods</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1.">Synthesis of Diopside BG</head><p>Diopside (CaMgSi 2 O 6 ) powder was synthesized using a sol&#177;gel method: 2.1 g of calcium nitrate tetrahydrate (Acros Organics, 99+%, Geel, Belgium) and 2.0 g of magnesium chloride hexahydrate (Acros Organics, 99%) were dissolved in 200-proof ethanol (Decon Labs, King of Prussia, PA, USA). The solution was magnetically stirred at 250 rpm for 30 min at room temperature. Then, 20 mL of tetraethyl orthosilicate (Acros Organics, 98%) was added to the solution and stirred at 450 rpm for 24 h at 80 &#8226; C until a gel was formed. The gel was then dried at 100 &#8226; C for 5 days to obtain a xerogel, which was then manually milled with a mortar and pestle until an evenly fine powder was reached. The powder was calcinated in a furnace at 850 &#8226; C for 2 h.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.">Casting of MMNC</head><p>A negative sand mold was made using an oil-based sand (PMC Supplies LLC, Lake Katrine, NY, USA) with a riser and sprue to reach approximate laminar flow into the cavity. For the melting, magnesium (ThermoScientific, Waltham, MA, USA, 99.8% pure), scandium (Luciteria Science, Olympia, WA, USA 99.95% pure, 3 wt%), and the BG (0.5 wt%) were added to a graphite crucible and heated to 930 &#8226; C (1700 &#8226; F) under a constant argon atmosphere. The strontium (Luciteria Science, 99.9% pure, 0.3 wt%) was added last to reduce its oxidation. A graphite rod was inserted into the melt and stirred for 30 s to begin mixing. As a control, magnesium was cast using 99.8% pure Mg. WE43 (Goodfellow, Huntingdon, UK, Mg93-Y4-Nd3) was sourced as a commercialized control.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Ultrasonic Melt Processing</head><p>Ultrasound processing of the melt was conducted using a Hielscher UP200st (Hielscher Ultrasonics, Teltow, Germany), equipped with a ceramic sonotrode and an air circulation system to keep the transducer cool during the process. Prior to insertion, the temperature of the furnace was increased to 980 &#8226; C (1800 &#8226; F), and the sonotrode was pre-heated above the open furnace to prevent significant melt solidification on the probe. The probe was inserted into the melt approximately one centimeter from the bottom of the crucible. The melt underwent a 1 min treatment consisting of 6 cycles of 6 s on and 4 s off at a power output of 1 watt at 50% amplitude (maximum amplitude 35 &#181;m). Shortly after the treatment was completed, slag was removed, and the entire melt was cast into a sand mold and allowed to cool for 2 h before extraction. The riser and sprue were cut and excluded from further analysis due to their non-uniform microstructure and inclusions.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Heat Treatment</head><p>Heat treatment was performed at 400 &#8226; C for 6 h to homogenize the microstructure. Samples were placed in quartz tubes topped with aluminum foil to prevent surface oxidation. After heating, samples were cooled to room temperature under ambient conditions while remaining in the quartz tubes.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5.">Hot Rolling</head><p>Samples were machined to 6.3 mm diameter and pre-heated for one hour at 400 &#8226; C in aluminum foil-topped quartz tubes. Samples were removed from the tubes and rolled to 6.0 mm diameter. A second pre-heating and rolling to 5.0 mm diameter was performed to further reduce grain sizes.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.6.">Microstructural Characterization</head><p>Samples were cut using a wafering saw (Dimost, Suzhou, China, CT-2300), cleaned with 70% ethanol, and polished using an EXAKT 400 CS Microgrinder (Exakt Technologies, Inc., Oklahoma City, OK, USA) with ascending grits, finishing with 1200 grit. Polishing was performed with a clean felt pad and 0.5 &#181;m alumina particles. After polishing, samples were cleaned with 70% ethanol and rinsed, then sonicated for 3 min in acetone to remove any surface contamination or organic materials. Samples were then etched in a nitric acid, acetic acid, and polyethylene glycol solution for approximately thirty seconds before rinsing with ethanol and deionized water to stop the etching process. A Keyence VHX microscope was used for microstructural imaging at 200&#215; and 700&#215; magnification.</p><p>After etching, images were analyzed for grain size measurements using ASTM E112 standards <ref type="bibr">[33]</ref>. Mean lineal intercepts were calculated using ImageJ (version 153k, ImageJ, Bethesda, MD, USA) for measurements. In total, 11 replicates were randomly selected from various metallography images, and calculated grain sizes were recorded.</p><p>Further microstructural analysis was performed using scanning electron microscopy (SEM; Zeiss, Oberkochen, Germany, ULTRA-55 FEG) equipped with an energy-dispersive spectrometer (EDS; Noran System 7). The accelerating voltage and aperture size were 20 kV and 30 &#181;m. Samples were coated with gold (Au) using a sputter coater (Quorum, Lewes, UK, EMS150T ES) to avoid surface charge on the samples. Furthermore, the morphology and size of the BG nanoparticles were observed using transmission electron microscopy (TEM, JEM-1011; JEOL, Tokyo, Japan) to examine the morphology and size of the synthesized BG nanoparticles after calcination.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.7.">Compression Testing</head><p>Compression testing was conducted in accordance with ASTM E9 standards <ref type="bibr">[34]</ref>. Samples were cut to a length-to-diameter ratio of 2:1, assuring that the two faces were as parallel as possible. Tests were conducted on a TestResources model 313 with a crosshead speed of 0.5 mm/mm/min. Yield stress (&#963; Y ) was determined by identifying the linear elastic region of the compression test curve and applying a 0.2% offset. Ultimate compressive strength (UCS) was calculated as the maximum stress recorded during the compression test. The maximum compressive strain at the point of fracture was measured and reported as the elongation at break (% elongation).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.8.">Electrochemical Corrosion Testing</head><p>Samples were subject to electrochemical analysis using a potentiostat (Biologic, Sp-50e, Biologic, Seyssinet-Pariset, France). Samples were cut to 3 mm segments from the rods and sequentially polished with 320-, 600-, and 1200-grit silicon carbide paper. Samples for corrosion testing were cut from different regions to evaluate the homogeneity of the microstructure and composition across the rods using corrosion data. WE43, Mg, ultrasonically treated (UST) MMNC, and unprocessed MMNC were loaded into a conductive sample holder with 0.5 cm 2 of surface area exposed for corrosion testing. However, the 5.3 mm diameter of the UST Rolled MMNC sample could not be fit into the commercial sample holder without causing leakage. As a result, these samples were wrapped with conductive wire and mounted in resin before polishing. The exposed surface area for the UST Rolled MMNC composition was 0.19 cm 2 .</p><p>Samples were submerged in 200 mL of Hanks Balanced Salt Solution (HBSS) with Ca and Mg (Cytiva) adjusted to pH 7.4 &#177; 0.05. The solution temperature was maintained at 37 &#177; 1 &#8226; C via water bath. Corrosion properties were investigated using a traditional three-electrode electrochemical cell. Each experimental condition involved the working electrode connected to a graphite counter electrode and an Ag/AgCl reference electrode attached via a bridge tube.</p><p>Electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization tests (PDP) were captured and analyzed using the EC-Lab &#174; v11.43 (Biologic, France) software. The test began with a 55 min open circuit voltage (OCV) test. Single sine EIS analysis immediately followed OCV at frequency ranging from 100,000 Hz to 0.01 Hz and amplitude of 10 mV. EIS data were reported as a Nyquist plot and analyzed using EC-Labs software v11.43 (Biologic, France) with the equivalent circuit. PDP was conducted at a scanning rate of 10 mV/min and from -0.2 V to 0.2 V of OCV immediately after the EIS test. Tafel fit lines derived from slopes at &#177;20 mV and &#177;50 mV were used to extrapolate the corrosion current density (I corr ), and corrosion potential (E corr ) in the EC-Labs software v11.43. The corrosion rate was calculated with Equation (1) established in ASTM G59 <ref type="bibr">[35]</ref>:</p><p>where I corr is the corrosion current density (&#181;A/cm 2 ) of the sample, EW is the sample equivalent weight of 12.15 g/eq for Mg based on oxidation from Mg to Mg 2+ , and &#961; is the density of Mg considered to be 1.74 g/cm 3 . Six samples were analyzed in each condition.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.9.">Immersion Testing</head><p>Immersion testing was conducted in HBSS to measure corrosion rate. Samples were machined and cut to approximate diameters of 5 mm and lengths of 10 mm. After machining and cutting, samples were polished with 1200-grit sandpaper and washed in a sonicated acetone bath for 3 min to remove any oils or organic residues on the surface. Following ASTM G31 guidelines, the samples were weighed to an accuracy of &#177;0.001 g and immersed in pH-corrected HBSS (7.4 &#177; 0.05) at a volume-to-surface area ratio of 0.2 mL/mm 2 <ref type="bibr">[36]</ref>. Samples were immersed for 1, 3, 7, or 10 days in HBSS in glass beakers covered with Parafilm. Beakers were immersed in a water bath at 37 &#8226; C to mimic body temperatures and HBSS was refreshed every 72 h.</p><p>Corroded samples were removed from HBSS at the end of incubation and dried in an oven at 100 &#8226; C to stop further corrosion. Corroded weights were measured using a LEADZM electronic balance and recorded to an accuracy of &#177;0.001 g. Corrosion products were removed using 200 g/L chromic acid immersion for 10 min followed by a 5 min rinse in 200-proof ethanol. Samples were weighed after washing, and the change in mass was used to calculate the corrosion rate via mass loss percent following Equation ( <ref type="formula">2</ref>), where &#8710;m is the change in mass calculated after corrosion products were removed. A is the surface area of the samples, T is the time immersed in hours, and D is the density of the samples.</p><p>Corrosion Rate(mmyr) = (87, 600 &#215; &#8710;m)/(A &#215; T &#215; D)</p><p>(2)</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.10.">Statistical Analysis</head><p>Metallographic imaging was performed on 1&#177;2 samples per group, selected from different sections of the cast rods, and representative images were chosen. Mechanical testing samples were cut from randomized sections of the cast rods, with 5 replicates per group. Electrochemical testing was conducted with 6 replicates per group. For immersion testing, 3 replicates per group were used for each time point. The results are presented as mean &#177; standard deviation. Statistical analyses were carried out using oneway ANOVA with Tukey's post hoc analysis in GraphPad Prism 10.2.3 software (San Diego, CA, USA). Statistical significance was considered at p &#8804; 0.05, with results reported as follows: * p &#8804; 0.05, **p &#8804; 0.01, *** p &#8804; 0.001, **** p &#8804; 0.0001.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Results</head><p>Figure <ref type="figure">1</ref> shows the polished and etched surfaces of each material. In UST and UST Rolled MMNCs, the increased concentration of dark regions along the grain boundaries and within the grains likely corresponds to diopside bioactive glass&#177;ceramic (BG) nanoparticles. Rolling led to a significant reduction in grain size and induced deformation twinning within the MMNC matrix. The rolled samples exhibit increased segregation of BG along the grain boundaries, as the grain deformation during hot rolling drives the nanoparticles toward these regions. Compared to Mg, UST MMNCs showed a more refined grain microstructure, with BG nano-reinforcements dispersed throughout the Mg matrix. However, when rolling is performed on UST MMNCs, the grain size is reduced. Moreover, the simultaneous application of high temperature and pressure enhanced the nucleation of intermetallics, primarily along the grain boundaries and at the sites of nano-reinforcements. Overall, both UST MMNCs and UST Rolled MMNCs displayed a significantly more refined grain structure, with smaller and more uniform grain sizes compared to Mg. UST MMNCs and unprocessed MMNCs showed similar grain sizes, with UST MMNC having smaller grains (112.2 &#177; 40.2, 148.4 &#177; 60.75, respectively, p &gt; 0.05). UST Rolled MMNCs showed a grain size of 51.78 &#177; 26.56, significantly lower than unprocessed MMNCs (p &lt; 0.0001) and UST Rolled MMNCs (p &lt; 0.01). Figure <ref type="figure">2</ref> presents the SEM images of unprocessed MMNC, UST MMNC, and UST Rolled MMNC and the results of EDS analysis. In Figure <ref type="figure">2A</ref>, precipitates are observed accumulating along the grain boundaries, which exhibit a discontinuous interface, indicating poor matrix integrity. The inset in Figure <ref type="figure">2A</ref> is enlarged in Figure <ref type="figure">2B</ref>, which highlights the EDS analysis area predominantly composed of Mg, O, and Sr (Figure <ref type="figure">2C</ref>). For UST MMNC, the dispersion of particles within the matrix appears more homogeneous, demonstrating improved integrity compared to the unprocessed sample (Figure <ref type="figure">2D</ref>,<ref type="figure">E</ref>). The selected inset in Figure <ref type="figure">2E</ref> reveals a significant presence of Si (0.3 &#177; 0.2 wt.%) and Ca (2.2 &#177; 0.2 wt.%), indicating the dispersion of BG nanoparticle aggregates. However, some BG nanoparticles remain aggregated and exhibit irregular shapes after the UST process. Conversely, UST Rolled MMNC displays smaller, round particles with a more uniform distribution (Figure <ref type="figure">2G</ref>,<ref type="figure">H</ref>). The EDS results for UST Rolled MMNC (Figure <ref type="figure">2I</ref>) indicate the presence of Si (0.3 &#177; 0.1 wt.%), indicating the incorporation of BG. In addition, the Sc concentration was highest in the following order: UST MMNC (1.3 &#177; 0.3 wt.%), UST Rolled MMNC (0.5 &#177; 0.1 wt.%), and unprocessed MMNC (0.1 &#177; 0.1 wt.%). Figure <ref type="figure">2J</ref> demonstrates the TEM image of BG nanoparticles after calcination at 850 &#8226; C for 2 h. It is composed of 3&#177;5 nanoparticles with varying morphologies, ranging from elongated to semi-spherical shapes. Compression testing was performed on the samples to evaluate their potential as loadbearing bone implants. WE43 was used as a control due to its well-documented properties and its established commercial use in bone implants. WE43 has been reported to have a yield stress, &#963; y , of about 240 MPa, an ultimate compressive stress, UCS, of approximately 400 MPa, and a percent elongation at break of about 17% <ref type="bibr">[37]</ref>. These reported values are comparable to our WE43 measurements of &#963; y (209 &#177; 8.71), UCS (393 &#177; 2.8), and percent elongation (17.02 &#177; 0.74) (Figure <ref type="figure">3</ref> and Table <ref type="table">1</ref>). Compression testing showed that the Mg had a significantly lower (p &lt; 0.05) yield stress than the UST MMNCs and UST Rolled MMNCs, but not compared to unprocessed MMNC. The hot rolling process led to a significantly higher UCS compared to the UST MMNCs, while having no significant effect on the yield strength. Similarly, the percent elongation at break for rolled MMNCs was significantly lower (p &lt; 0.05), showing a reduction of 45% compared to the unrolled UST samples.   ff &#8804; &#8804; &#8804; Figure 4. (A) PDP curves for WE43, Mg, unprocessed MMNC, UST MMNC, and UST Rolled MMNC, illustrating the average corrosion behavior of samples during electrochemical testing. (B) Corrosion rate (in mm per year, mmpy), showing a significant reduction for UST Rolled MMNCs compared to other MMNCs. (C) Corrosion current density (Icorr) follows similar trends, with a significant decrease for UST Rolled MMNCs. (D) Corrosion potential (Ecorr) is elevated in UST Rolled MMNCs relative to the other samples. One-way ANOVA: * p &#8804; 0.05; n = 6 per group.</p><p>Corrosion current density indicates the rate of corrosion, while corrosion potential represents the equilibrium between oxidation and reduction reactions at the metal's surface <ref type="bibr">[38]</ref>. Samples with higher, or more positive, corrosion potentials are more likely to gain electrons rather than lose them, reducing their tendency to corrode <ref type="bibr">[38]</ref>. Furthermore, a lower corrosion current density suggests a lower corrosion rate <ref type="bibr">[38]</ref>. Both the unprocessed MMNC and UST MMNC were characterized by corrosion potentials near that of Mg and higher than WE43. The UST Rolled MMNCs displayed the highest E corr of -1.44 &#177; 0.08 V, compared to other groups, including WE43 which displayed an E corr of -1.6 &#177; 0.06 V.</p><p>Tafel-derived corrosion current densities show that there are significant differences (p &lt; 0.05) between I corr of the UST Rolled MMNC and that of the UST MMNC. The I corr of the UST Rolled MMNC was 1.55 &#177; 0.67 &#181;A/cm 2 compared to the I corr of 5.53 &#177; 2.01 &#181;A/cm 2 in the UST MMNC. Significant differences also exist between the UST Rolled MMNC and Mg (I corr = 5.48 &#177; 1.58 &#181;A/cm 2 ) and the unprocessed MMNC, where I corr was 5.63 &#177; 3.85 &#181;A/cm 2 . The near 110 mV difference in E corr , along with these findings, suggests that the changes induced by the rolling process are significant, leading to increased corrosion resistance in the UST Rolled MMNC. These modifications result in the UST Rolled MMNC exhibiting a current density similar to that of commercialized WE43, although the difference between the two groups is not statistically significant (p &gt; 0.05).</p><p>The UST Rolled MMNC displayed the lowest corrosion rate of all groups. The corrosion rate of the UST Rolled MMNC was 0.03 &#177; 0.02&#208;a 4-fold reduction in corrosion rate compared to rates of 0.13 mm per year (mmpy) in the UST MMNC, Mg, and unprocessed MMNC. No significant difference (p &gt; 0.05) was determined between corrosion rates of UST Rolled MMNC and WE43. The trend in corrosion rates corresponds directly to the trend in current density and corrosion potential. Furthermore, the trends are justified by the interrelation of corrosion rate and current density through the formula established in ASTM G59 (Equation ( <ref type="formula">1</ref>)) <ref type="bibr">[35]</ref>. It is also notable that the unprocessed MMNC exhibited greater variation in corrosion, likely due to non-uniform microstructures across samples. This underscores the role of UST in producing more uniform microstructures and consistent corrosion rates.</p><p>Figure <ref type="figure">5A</ref>,B depict the results of electrochemical impedance spectroscopy (EIS) for the representative curves closest to the average for each condition. The simulated equivalent circuit used to evaluate each Nyquist plot can be found inlayed in Figure <ref type="figure">5A</ref>. This equivalent circuit was drafted based on the presence of both high-and low-frequency capacitive loops in the Nyquist plots of all samples <ref type="bibr">[39]</ref>. Mg alloys characterized by this type of impedance behavior exhibit two porous layers, the outer layer of which can indicate the formation of a protective corrosion layer <ref type="bibr">[39,</ref><ref type="bibr">40]</ref>.</p><p>The layers are modeled using two elements: electrical resistance (R) and a capacitance/constant phase element (Q), with an impedance defined as Z Q = Q 0 (i.&#969;) n (Q 0 = constant; i = imaginary number; &#969; = angular frequency; and n = coefficient between 0.5 and 1). When n approaches 1, it indicates near-ideal capacitance, suggesting an effective barrier to solution penetration <ref type="bibr">[41]</ref>. The accuracy of the fitting models was evaluated by comparing the reduced chi-square (&#967; 2 /|Z|), which represents the ratio of observed experimental variance to theoretical variance. Although &#967; 2 /|Z| is less than 1, indicating minimal noise in the data, the model effectively fits the raw Nyquist data.</p><p>Among the values represented by the equivalent circuit, R 1 indicates the solution resistance (R s ) characteristic of the electrolytes in HBSS. R 2 and Q 1 indicate the resistance and capacitance, respectively, between the protective outer porous layer and solution. The charge transfer resistance and capacitance at the inner layer of the alloy are represented by R 3 and Q 2 , respectively. EIS data extrapolated from equivalent circuits using EC-Lab software v11.43 are summarized in Table <ref type="table">2</ref>, with polarization resistance (R p ) being of particular significance. All six replicates of a single group were analyzed sequentially before proceeding to the next sample. Q 1 for Mg (6.21 &#177; 2.07 &#181;F&#8226;cm -2 &#8226;s n ), UST MMNC (6.88 &#177; 4.02 &#181;F&#8226;cm -2 &#8226;s n ), and UST Rolled MMNC (6.25 &#177; 6.34 &#181;F&#8226;cm -2 &#8226;s n ) shows smaller values compared to WE43 (8.38 &#177; 3.55 &#181;F&#8226;cm -2 &#8226;s n ) and unprocessed MMNC (9.89 &#177; 7.72 &#181;F&#8226;cm -2 &#8226;s n ), while the n 1 values are quite similar in all groups (0.68&#177;0.71). On the other hand, Q 2 is significantly higher for UST Rolled MMNC (155.97 &#177; 375.88 &#181;F&#8226;cm -2 &#8226;s n ) compared to the other groups and is a less ideal capacitance (n 2 = 0.75 &#177; 0.33). The outer-and inner-layer resistance for UST Rolled MMNCs (R 2 = 1365.69 &#177; 2545.17 Ohm&#8226;cm 2 and R 3 = 20,213.85 &#177; 13,413.07 Ohm&#8226;cm 2 ) show relatively higher values compared to the other groups (Table <ref type="table">2</ref>). Consequently, the UST Rolled MMNC displayed R p of 21,579.54 &#177; 11,839.93 Ohm&#8226;cm 2 , almost two-fold higher than the next highest value of 13,006.51 &#177; 1072.27 Ohm&#8226;cm 2 in the WE43 condition. These R p values in Table <ref type="table">2</ref> also correspond to the size of the capacitive loops in the Nyquist plot of each sample as larger capacitive loops correspond to higher resistance values and better protection against corrosion. The data in Table <ref type="table">2</ref> show that UST rolling produced the most pronounced increase in the polarization resistance of the sample. Resistance at the outer porous layer of the samples was also highest in the UST Rolled MMNC group, at 1365.69 &#177; 2545.17 Although UST Rolled MMNC exhibited a significantly higher corrosion rate than all other samples at the initial immersion, its corrosion rate remained statistically constant over the incubation period. In contrast, other groups showed increasing corrosion rates with longer immersion times (Figure <ref type="figure">6</ref>, Table <ref type="table">3</ref>). After 7 days of immersion, unprocessed MMNC exhibited a significant increase in corrosion rate, rising ten-fold. Similarly, between days 3 and 7, UST MMNC showed a 3.8-fold increase in corrosion rate and began showing statistically significant differences in corrosion rates compared to Mg. Rolled MMNCs (I) demonstrated consistently stable corrosion rates, which were higher than the control WE43 (E) and Mg (F), and generally higher than UST MMNCs (H). Unprocessed MMNCs (G) exhibited a rapid increase in corrosion rate with immersion time, while UST MMNCs showed a similar trend but at one-fifth of the magnitude. In contrast, UST Rolled MMNCs maintained a more stable corrosion rate throughout the tests. One-way ANOVA: * p &#8804; 0.05, *** p &#8804; 0.001, **** p &#8804; 0.0001; n = 3 per group.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Table 2. Electrochemical corrosion parameters extrapolated from EIS analysis (n = 6 per group).</head><p>Definitions of the values are the following: R s : solution resistance; R p : polarization resistance; Q 1 : capacitance of the outer oxide layer; n 1 : coefficient of Q 1 ; R 2 : resistance at the outer oxide layer/solution interface; Q 2 : capacitance of the inner layer of the alloy; R 3 : charge transfer resistance at the inner layer of the alloy; </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.">Discussion</head><p>This study demonstrates the significant impact of ultrasonic melt treatment (UST) on the microstructure, mechanical properties, and corrosion resistance of a novel magnesiumbased metal matrix nanocomposite (MMNC). We also investigated the effects of rolling on UST MMNC, finding improvements in the consistency of corrosion rates, an increase in yield stress, and a reduction in percent elongation at break. Additionally, regardless of the processing techniques, adding alloying elements and nano-reinforcements led to increased ultimate compressive strength and yield stress compared to Mg.</p><p>Ultrasonication of the melt was selected as the treatment method due to its ability to induce acoustic streaming and bubble cavitation in the melt <ref type="bibr">[22,</ref><ref type="bibr">42,</ref><ref type="bibr">43]</ref>. Preliminary testing revealed inconsistent corrosion results with adding bioactive glass&#177;ceramic nanoparticles (BG) at significantly higher weight percentages than the current 0.5 wt.%. Reducing the BG concentration minimized agglomeration, as the lower overall amount of BG reduced the tendency for clustering. Subsequently, ultrasonic melt treatment was used to deagglomerate and disperse the BG uniformly within the melt while also degassing the melt through acoustic streaming and bubble cavitation effects. This uniformity in microstructure is evident in the metallography images shown in Figure <ref type="figure">1</ref>. However, the UST MMNC still exhibits large grains, potentially due to the low solidification rate of the melt in the sand mold. Previous research has shown that grain size significantly affects the corrosion rate of Mg <ref type="bibr">[44,</ref><ref type="bibr">45]</ref>. Future work may involve optimizing the mold dimensions and mold material to enhance solidification rates. In addition, further refinement of the ultrasonic melt treatment process could help reduce grain sizes and achieve more controlled corrosion properties. Hot rolling was selected to reduce grain size and enhance the integration between the Mg matrix and BG reinforcements due to its simplicity and accessibility. However, this method is limited by the number of cycles achievable, as it necessitates a significant reduction in cross-sectional area during the process.</p><p>Ultrasonication of the melt did not lead to a significant reduction in grain size. The primary goal of melt sonication is to de-agglomerate and disperse BG nanoparticles while inducing cavitation of trapped gas, thereby reducing structural defects and casting porosity. The enhanced dispersion of BG was expected to promote grain nucleation, potentially resulting in smaller grain sizes. However, due to the solidification rate of the melt in the sand mold and the subsequent heat treatment, the impact of ultrasonication on grain size was negligible. Emadi et al. demonstrated that ultrasonication of an AZ91E Mg alloy melt significantly influenced grain size after a 24-h heat treatment <ref type="bibr">[46]</ref>. In contrast, metallographic imaging of AZ91E in their study revealed a considerable presence of secondary beta phase throughout the SEM images. At higher amplitudes, ultrasonication led to a reduction in the segregation of large beta-phase areas. In our case, however, the minimal presence of secondary phases in MMNCs due to the low levels of alloying elements resulted in a more negligible effect of ultrasonication on grain size.</p><p>The SEM/EDS results indicated that UST improved the wettability of the BG particles, leading to a more homogeneous dispersion compared to the unprocessed sample (Figure <ref type="figure">2A</ref>,<ref type="figure">D</ref>). The rolling process further enhanced this dispersion, as illustrated in Figure <ref type="figure">2G</ref>. The morphology of the BG particles underwent a significant transformation into a spherical shape, likely due to deformation and breakdown of BG nanoparticle aggregates during the rolling process. The shape of the reinforcing particles has been shown to influence the biodegradation of Mg/HA nanocomposites <ref type="bibr">[47]</ref>. Similarly, in this study, the UST Rolled MMNC exhibited the lowest corrosion current density (1.55 &#177; 0.67 &#181;A/cm 2 ), corrosion rate (0.03 &#177; 0.02 mmpy), and polarization resistance (21,579.54 &#177; 11,839.93 Ohm&#8226;cm 2 ). However, the immersion results indicated an increased corrosion rate, necessitating a prolonged EIS test to elucidate the underlying reasons. One potential explanation could be the higher density of grain boundaries, which may have facilitated passivation during the initial stages of corrosion, as measured by electrochemical methods. Additionally, the presence of significant amounts of oxide could have contributed to the disintegration of the matrix, while solution penetration may have diminished corrosion resistance. Oxidation may have occurred during the heat treatment before rolling, as evidenced by SEM/EDS (Figure <ref type="figure">2I</ref>). The UST Rolled MMNC had the highest O content of 54.4 &#177; 0.7 wt.%. The homogeneous dispersion of the BG particles also increased yield strength, following the order UST Rolled MMNC &gt; UST MMNC &gt; unprocessed MMNC. In metal matrix composites, particle strengthening is a mechanism that enhances yield strength <ref type="bibr">[48]</ref>. Furthermore, the shape, size, and quantity of the particles can significantly influence mechanical properties, such as crack initiation within the matrix. Smaller particles with a narrow size distribution tend to reduce the likelihood of crack formation.</p><p>Hot rolling also offers additional benefits, such as increased pressure and temperature, enhancing the nucleation and growth of intermetallic phases. This increases yield stress and ultimate compressive strength (UCS) in the UST Rolled MMNC while reducing elongation at break. However, the formation of intermetallic phases can increase the risk of microgalvanic pitting corrosion due to variations in electrochemical corrosion potentials relative to the Mg matrix. The segregation of intermetallics at grain boundaries, as in Figure <ref type="figure">1</ref>, can lead to pitting corrosion along these boundaries. This can result in intergranular corrosion, pit-to-crack transition, and early material failure. Another major drawback of the hot rolling process is the introduction of stress-induced twinning and microcracks. The roughness from twinning at the micron scale increases the surface area, which can significantly enhance pitting corrosion <ref type="bibr">[49]</ref>. Likewise, microcracks formed during the significant plastic deformation during hot rolling may act as initiation sites for further pitting corrosion.</p><p>The corrosion behavior observed during electrochemical corrosion testing can be attributed to the microstructural changes induced by the UST rolling process. Specifically, the increased compressive residual stress and dislocation density contribute to enhanced recrystallization and grain refinement <ref type="bibr">[50,</ref><ref type="bibr">51]</ref>, while also promoting the closure of matrixreinforcement interfacial gaps. High dislocation levels and subtle defects introduced by the rolling process can create diffusion pathways for elements to reach the metal surface, forming a protective oxide layer that enhances corrosion resistance <ref type="bibr">[51]</ref>. Corrosion rates calculated via PDP analysis are supported by a study from Deng et al., examining the corrosion behavior of Mg alloys. They concluded that hot rolling significantly reduced the corrosion rate by up to three times, with the effect being temperature-dependent <ref type="bibr">[52]</ref>.</p><p>Generally, the charge transfer resistance (R 3 in Table <ref type="table">2</ref>) indicates the dissolution rate of Mg, and higher values equate to slower rates of dissolution, specifically lower corrosion rates <ref type="bibr">[53]</ref>. When analyzed, the charge transfer resistance values (R 3 ) were highest in the WE43 and UST Rolled MMNCs, at 12,873.20 &#177; 1074.57 Ohm&#8226;cm 2 and 20,213.85 &#177; 13,413.07 Ohm&#8226;cm 2 , respectively. These data demonstrate over a two-fold difference from the UST MMNC, Mg, and unprocessed MMNCs compared to WE43 and a four-fold difference compared to the UST Rolled MMNCs. These conclusions further underscore the significant impact of integrated UST and rolling processes on the corrosion resistance of MMNC. It is also important to note that the electrochemical behavior of the MMNCs is expected to change as the surfaces of the samples are oxidized and corroded. Due to this expectation, further study into the electrochemical behavior of already-immersed samples should be conducted to validate existing EIS and immersion discrepancies, as well as to study the possible beneficial effects of creating a passivation layer via immersion prior to electrochemical studies.</p><p>Immersion testing was used to confirm the corrosion rate of MMNC calculated from electrochemical testing. However, extended immersion testing, compared to electrochemical testing, may accelerate pit formation and the transition from pits to cracks due to micro-galvanic corrosion between the matrix, intermetallics, and nano-reinforcements, potentially leading to significantly higher corrosion rates <ref type="bibr">[54]</ref>. The corrosion of the Mg matrix is evident from the formation of small bubbles on the sample surfaces as immersion time increases. While similar bubbles are observed on electrochemical corrosion samples, they appear at a much smaller scale and in fewer quantities. Variation may also be due to the creation of a passivation layer during the initial stages of the electrochemical corrosion test, prior to the EIS and PDP measurements.</p><p>The study of Mg-based alloys and composites is well established, with extensive research exploring a variety of testing media for these samples. Initially, solutions of NaCl had been used according to ASTM standards, but due to the significant differences in ionic compositions, physiological comparisons between these results and in vivo studies showed significant differences in the corrosion behavior and resulting corrosion products <ref type="bibr">[55]</ref>. Due to these differences, immersion tests have evolved to include specific valid compositions such as Hanks Balanced Salt Solutions (HBSS), simulated body fluid (SBF), and Dulbecco's Phosphate-Buffered Saline (DPBS). Each of these fluids have various ionic profiles, specially formulated to imitate some aspect of physiological solutions.</p><p>Mena-Morcillo and Veleva recently studied the effect that varying the immersion media had on the corrosion rate of AZ31 and AZ91 <ref type="bibr">[56]</ref>. They observed a significant variation in corrosion rates between HBSS, SBF, and Ringer's solution. Specifically, HBSS resulted in a mass loss rate approximately three times lower than that observed in SBF. Additionally, Mei et al. discussed criteria for selecting the appropriate immersion media in their 2020 review <ref type="bibr">[55]</ref>. They concluded that simulated body fluids like SBF and HBSS were suitable for open immersion tests due to the lack of sugars and other elements that would cause microbial contaminations to tamper with the data. They also concluded that the corrosion rate of Mg samples in HBSS-like media would be &#170;revelated to a lesser extent&#186; when compared to NaCl solutions due to the various ionic interactions between the Mg matrix and the ionic solution. However, the human body has a complex ionically stable and pH-stable condition that significantly contributes to the behavior of the implants in situ.</p><p>It is widely reported that static immersion tests, like the one we conducted, often show higher corrosion rates compared to in vivo studies [57&#177;59]. This discrepancy arises because in vivo specimens experience a constantly changing environment due to the circulatory system, which maintains a homeostatic ion exchange. Additionally, the presence of enzymes and proteins in vivo can contribute to the formation of protective layers.</p><p>Although UST and integrated UST rolling processes are effective in the microstructural refinement of MMNC, further optimization can be achieved in future regarding the ultrasound intensity, duration, amplitude, and hot rolling temperature to further reduce grain sizes, de-agglomerate and disperse nano-reinforcements, and reduce intermetallic and twining formation. Further optimization of MMNC composition and processing may enhance microstructure, corrosion resistance, and mechanical properties in future studies. In future studies, the formation of corrosion products will be investigated to better understand the corrosion mechanisms and the effects of biomineralization on corrosion rates. Other severe plastic deformation methods can also be used to reduce grain sizes, thereby elucidating the effects of processing on microstructure and resulting corrosion and mechanical properties.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.">Conclusions</head><p>The fabrication of a novel MMNC composition using ultrasonic melt processing and hot rolling resulted in significant increases in the yield stress and ultimate compressive strength of samples while decreasing the elongation at break. Likewise, ultrasonication independently increased the corrosion resistance of the samples when immersed in a static HBSS solution and improved the corrosion behavior, as seen in the electrochemical analysis. The sonication of the melt did not significantly change the mechanical properties of the MMNC but did result in lower corrosion rates. Further processing of samples with hot rolling increased the corrosion rate, but it remained lower than the unprocessed and UST-processed MMNCs.</p></div></body>
		</text>
</TEI>
