skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Reflection-mode diffraction tomography of multiple-scattering samples on a reflective substrate from intensity images
We introduce a reflection-mode diffraction tomography technique that enables the simultaneous recovery of forward- and backward-scattering information for high-resolution 3D refractive index reconstruction. Our technique works by imaging a sample on a highly reflective substrate and employing a multiple-scattering model and a reconstruction algorithm. It combines the modified Born series as the forward model, Bloch and perfect electric conductor boundary conditions to handle oblique incidence and substrate reflections, and the adjoint method for efficient gradient computation in solving the inverse-scattering problem. We validate the technique through simulations and experiments, achieving accurate reconstructions in samples with high refractive index contrasts and complex geometries. Forward scattering captures smooth axial features, while backward scattering reveals complementary interfacial details. Experimental results on dual-layer resolution targets, 3D randomly distributed beads, phase structures obscured by highly scattering fibers, fixed breast cancer cells, and fixedC. elegansdemonstrate its robustness and versatility. This technique holds promise for applications in semiconductor metrology and biomedical imaging.  more » « less
Award ID(s):
1846784
PAR ID:
10577274
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optica
Volume:
12
Issue:
3
ISSN:
2334-2536
Format(s):
Medium: X Size: Article No. 406
Size(s):
Article No. 406
Sponsoring Org:
National Science Foundation
More Like this
  1. We propose a novel intensity diffraction tomography (IDT) reconstruction algorithm based on the split-step non-paraxial (SSNP) model for recovering the 3D refractive index (RI) distribution of multiple-scattering biological samples. High-quality IDT reconstruction requires high-angle illumination to encode both low- and high- spatial frequency information of the 3D biological sample. We show that our SSNP model can more accurately compute multiple scattering from high-angle illumination compared to paraxial approximation-based multiple-scattering models. We apply this SSNP model to both sequential and multiplexed IDT techniques. We develop a unified reconstruction algorithm for both IDT modalities that is highly computationally efficient and is implemented by a modular automatic differentiation framework. We demonstrate the capability of our reconstruction algorithm on both weakly scattering buccal epithelial cells and strongly scattering liveC. elegansworms and liveC. elegansembryos. 
    more » « less
  2. We develop a novel algorithm for large-scale holographic reconstruction of 3D particle fields. Our method is based on a multiple-scattering beam propagation method (BPM) combined with sparse regularization that enables recovering dense 3D particles of high refractive index contrast from a single hologram. We show that the BPM-computed hologram generates intensity statistics closely matching with the experimental measurements and provides up to 9× higher accuracy than the single-scattering model. To solve the inverse problem, we devise a computationally efficient algorithm, which reduces the computation time by two orders of magnitude as compared to the state-of-the-art multiple-scattering based technique. We demonstrate the superior reconstruction accuracy in both simulations and experiments under different scattering strengths. We show that the BPM reconstruction significantly outperforms the single-scattering method in particular for deep imaging depths and high particle densities. 
    more » « less
  3. We propose a novel intensity diffraction tomography reconstruction algorithm based on the split-step non-paraxial model for recovering the 3D refractive index distribution of multiple-scattering biological samples. 
    more » « less
  4. Refractive index is an optical property explored in the light scattering measurement of micro- and nano-particles as well as in label-free imaging of cells and tissues. Because the refractive index value is a major input to the characterization and quantification of the analyzed specimens, various methods have been developed targeting at different sample types. In this paper, we demonstrate a technique for the refractive index measurement of homogeneous microspheres and liquids in the short-wave infrared (SWIR) range. We use synthetic phase microscopy (SPM), which records a scattering-corrected projection of the 3D refractive index distribution, in combination with a least-squares fitting to a theoretical model of a sphere. Using the method, we determine the refractive index dispersion of two polymer microspheres (polymethyl methacrylate and polystyrene), two glass microspheres (silica and soda lime), and three microscopy mounting media (glycerol, FluorSave, and Eukitt) in the SWIR range of 1100–1650 nm. 
    more » « less
  5. Laser speckle contrast imaging is widely used in clinical studies to monitor blood flow distribution. Speckle contrast tomography, similar to diffuse optical tomography, extends speckle contrast imaging to provide deep tissue blood flow information. However, the current speckle contrast tomography techniques suffer from poor spatial resolution and involve both computation and memory intensive reconstruction algorithms. In this work, we present SpeckleCam, a camera-based system to reconstruct high resolution 3D blood flow distribution deep inside the skin. Our approach replaces the traditional forward model using diffuse approximations with Monte-Carlo simulations-based convolutional forward model, which enables us to develop an improved deep tissue blood flow reconstruction algorithm. We show that our proposed approach can recover complex structures up to 6 mm deep inside a tissue-like scattering medium in the reflection geometry. We also conduct human experiments to demonstrate that our approach can detect reduced flow in major blood vessels during vascular occlusion. 
    more » « less