<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit</title></titleStmt>
			<publicationStmt>
				<publisher>Science</publisher>
				<date>09/20/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10597125</idno>
					<idno type="doi">10.1126/science.ado8069</idno>
					<title level='j'>Science</title>
<idno>0036-8075</idno>
<biblScope unit="volume">385</biblScope>
<biblScope unit="issue">6715</biblScope>					

					<author>Wenxuan Jia</author><author>Victoria Xu</author><author>Kevin Kuns</author><author>Masayuki Nakano</author><author>Lisa Barsotti</author><author>Matthew Evans</author><author>Nergis Mavalvala</author><author>R Abbott</author><author>I Abouelfettouh</author><author>R X Adhikari</author><author>A Ananyeva</author><author>S Appert</author><author>K Arai</author><author>N Aritomi</author><author>S M Aston</author><author>M Ball</author><author>S W Ballmer</author><author>D Barker</author><author>B K Berger</author><author>J Betzwieser</author><author>D Bhattacharjee</author><author>G Billingsley</author><author>N Bode</author><author>E Bonilla</author><author>V Bossilkov</author><author>A Branch</author><author>A F Brooks</author><author>D D Brown</author><author>J Bryant</author><author>C Cahillane</author><author>H Cao</author><author>E Capote</author><author>Y Chen</author><author>F Clara</author><author>J Collins</author><author>C M Compton</author><author>R Cottingham</author><author>D C Coyne</author><author>R Crouch</author><author>J Csizmazia</author><author>T J Cullen</author><author>L P Dartez</author><author>N Demos</author><author>E Dohmen</author><author>J C Driggers</author><author>S E Dwyer</author><author>A Effler</author><author>A Ejlli</author><author>T Etzel</author><author>J Feicht</author><author>R Frey</author><author>W Frischhertz</author><author>P Fritschel</author><author>V V Frolov</author><author>P Fulda</author><author>M Fyffe</author><author>D Ganapathy</author><author>B Gateley</author><author>J A Giaime</author><author>K D Giardina</author><author>J Glanzer</author><author>E Goetz</author><author>A W Goodwin-Jones</author><author>S Gras</author><author>C Gray</author><author>D Griffith</author><author>H Grote</author><author>T Guidry</author><author>E D Hall</author><author>J Hanks</author><author>J Hanson</author><author>M C Heintze</author><author>A F Helmling-Cornell</author><author>H Y Huang</author><author>Y Inoue</author><author>A L James</author><author>A Jennings</author><author>S Karat</author><author>M Kasprzack</author><author>K Kawabe</author><author>N Kijbunchoo</author><author>J S Kissel</author><author>A Kontos</author><author>R Kumar</author><author>M Landry</author><author>B Lantz</author><author>M Laxen</author><author>K Lee</author><author>M Lesovsky</author><author>F Llamas</author><author>M Lormand</author><author>H A Loughlin</author><author>R Macas</author><author>M MacInnis</author><author>C N Makarem</author><author>B Mannix</author><author>G L Mansell</author><author>R M Martin</author><author>N Maxwell</author><author>G McCarrol</author><author>R McCarthy</author><author>D E McClelland</author><author>S McCormick</author><author>L McCuller</author><author>T McRae</author><author>F Mera</author><author>E L Merilh</author><author>F Meylahn</author><author>R Mittleman</author><author>D Moraru</author><author>G Moreno</author><author>M Mould</author><author>A Mullavey</author><author>T_J N Nelson</author><author>A Neunzert</author><author>J Oberling</author><author>T O’Hanlon</author><author>C Osthelder</author><author>D J Ottaway</author><author>H Overmier</author><author>W Parker</author><author>A Pele</author><author>H Pham</author><author>M Pirello</author><author>V Quetschke</author><author>K E Ramirez</author><author>J Reyes</author><author>J W Richardson</author><author>M Robinson</author><author>J G Rollins</author><author>J H Romie</author><author>M P Ross</author><author>T Sadecki</author><author>A Sanchez</author><author>E J Sanchez</author><author>L E Sanchez</author><author>R L Savage</author><author>D Schaetzl</author><author>M G Schiworski</author><author>R Schnabel</author><author>R_M S Schofield</author><author>E Schwartz</author><author>D Sellers</author><author>T Shaffer</author><author>R W Short</author><author>D Sigg</author><author>B_J J Slagmolen</author><author>S Soni</author><author>L Sun</author><author>D B Tanner</author><author>M Thomas</author><author>P Thomas</author><author>K A Thorne</author><author>C I Torrie</author><author>G Traylor</author><author>G Vajente</author><author>J Vanosky</author><author>A Vecchio</author><author>P J Veitch</author><author>A M Vibhute</author><author>E_R G von_Reis</author><author>J Warner</author><author>B Weaver</author><author>R Weiss</author><author>C Whittle</author><author>B Willke</author><author>C C Wipf</author><author>H Yamamoto</author><author>H Yu</author><author>L Zhang</author><author>M E Zucker</author><author>members_of_the_LIGO_Scientific_Collaboration†</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[<p>The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot be simultaneously measured with arbitrary precision, giving rise to an apparent limitation known as the standard quantum limit (SQL). Gravitational-wave detectors use photons to continuously measure the positions of freely falling mirrors and so are affected by the SQL. We investigated the performance of the Laser Interferometer Gravitational-Wave Observatory (LIGO) after the experimental realization of frequency-dependent squeezing designed to surpass the SQL. For the LIGO Livingston detector, we found that the upgrade reduces quantum noise below the SQL by a maximum of three decibels between 35 and 75 hertz while achieving a broadband sensitivity improvement, increasing the overall detector sensitivity during astrophysical observations.</p>]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><p>The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot be simultaneously measured with arbitrary precision, giving rise to an apparent limitation known as the standard quantum limit (SQL). Gravitational-wave detectors use photons to continuously measure the positions of freely falling mirrors and so are affected by the SQL. We investigated the performance of the Laser Interferometer Gravitational-Wave Observatory (LIGO) after the experimental realization of frequency-dependent squeezing designed to surpass the SQL. For the LIGO Livingston detector, we found that the upgrade reduces quantum noise below the SQL by a maximum of three decibels between 35 and 75 hertz while achieving a broadband sensitivity improvement, increasing the overall detector sensitivity during astrophysical observations. A consequence of quantum mechanics is the Heisenberg uncertainty principle, which states that the product of the measurement noises of conjugate observables (such as position and momentum) cannot be less than &#8463;/2, where &#8463; is the reduced Planck constant. Measuring the position x of an object with uncertainty Dx inevitably perturbs its momentum by Dp &#8805; &#8463;/(Dx). After a time t, the object with mass m freely evolves, acquiring additional position uncertainty Dx&#8242; from the momentum perturbation Dx&#8242; = tDp/ m = &#8463;t/(2mDx). An extremely precise measurement (Dx &#8594; 0) will make the next position measurement totally unpredictable (Dx&#8242; &#8594; &#8734;) because of this phenomenon, which is known as quantum back action <ref type="bibr">(1)</ref>. The minimal repeatable uncertainty is achieved when</p><p>, which is known as the standard quantum limit (SQL) <ref type="bibr">(2,</ref><ref type="bibr">3)</ref>. The SQL applies to measurements of microscopic particles; it is also a limiting factor for the measurements made by interferometric gravitational-wave detectors, which measure attometer-scale displacements of macroscopic mirrors (4).</p><p>In principle, the SQL could be surpassed by introducing quantum correlations between the interferometer's laser light and the mirrors (5-7). Proposed designs that do this are known as quantum nondemolition interferometers <ref type="bibr">(8,</ref><ref type="bibr">9)</ref>. One approach proposed a squeezedinput interferometer, which would surpass the SQL at a particular frequency by injecting a nonclassical state of light, known as a squeezed vacuum state, into the interferometer. The addition of a detuned Fabry-P&#233;rot filter cavity would impose a frequency-dependent phase shift on the squeezed vacuum states reflected from it, allowing the SQL to be surpassed over a broader frequency range <ref type="bibr">(9)</ref>.</p><p>In a proof-of-principle demonstration, previous work injected squeezed vacuum states into the Laser Interferometer Gravitational-Wave Observatory (LIGO), producing quantum correlations and surpassing the SQL in a narrow frequency region (30 to 50 Hz) <ref type="bibr">(10)</ref>. However, because that experiment did not include a filter cavity, the quantum noise increased at all other frequencies, causing an overall decrease of the astrophysical sensitivity <ref type="bibr">(10)</ref>, as theoretically predicted <ref type="bibr">(9)</ref>. Subsequently, a 300-m-long filter cavity was added to both LIGO Livingston (L1) and Hanford (H1) interferometers, which was designed to extend the reduction of quantum noise over a broader frequency range <ref type="bibr">(11)</ref>. We examined the quantum noise performance of the LIGO L1 interferometer operating with this filter cavity.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Simplified quantum noise model</head><p>Gravitational-wave modulations of spacetime are quantified by the dimensionless strain h. A gravitational-wave detector converts these modulations into a measurable differential displacement between two pairs of suspended mirrors. In this case, Dx is the interferometer differential displacement, and h = Dx/L arm , where L arm is the length of each interferometer arm (4 km for LIGO). At measurement frequencies, the interferometer mirrors move freely, so the SQL for these mirrors can be expressed by considering the gravitational-wave strain noise amplitude spectral density</p><p>where W is the measurement frequency. This strain limit depends on the mass of the object rather than the number of photons used to probe its position (determined by the laser power). In LIGO, the effective mass of the object is the reduced mass (m/4) of the differential motion of each pair of arm cavity mirrors, each 40 kg, so</p><p>For clarity, we first present a simplified model of quantum noise in the LIGO interferometers developed in previous work <ref type="bibr">(11)</ref>. In the ideal lossless case, the power spectral density (PSD) of quantum noise S(W) can be expressed as</p><p>where K W &#240; &#222; is the opto-mechanical coupling strength; the first term represents noise from quantum back action, and the second term represents imprecision from photon shot noise. K W &#240; &#222;increases with the circulating laser power in arm cavities P arm as</p><p>where k 0 = 2p/(1064 nm) is the laser wave number, and g 0 &#8776; 2p &#215; 450 Hz is the detector's signal bandwidth. At frequencies below 40 Hz, measurement back action dominates because of the strong opto-mechanical coupling</p><p>, so the measurement imprecision noise dominates. The frequency at which these two forms of quantum noise contribute equally to the total quantum noise is called the SQL frequency W SQL , defined as</p><p>The value of W SQL scales with the square root of the laser power; for a circulating power of P arm = 260 kW, W SQL = 2p &#215; 37 Hz.</p><p>Together, these two forms of quantum noise enforce the SQL for displacement sensing (Eq. 3), which arises from the use of uncorrelated photons to probe mirror positions. Equation 3 enforces the SQL because it is an incoherent superposition of quantum back action and imprecision noise. In the presence of quantum correlations between light and mirrors, Eq. 3 no longer holds, allowing the SQL to be surpassed.</p><p>Squeezed vacuum is a nonclassical state of light that uses quantum correlations between photon pairs to reduce one form of quantum *Corresponding author. Email: wenxuanj@mit.edu (W.J.); victoriaa.xu@ligo.org (V.X.)</p><p>&#8224;LIGO Scientific Collaboration authors and affiliations are listed in the supplementary materials.</p><p>noise at the expense of the other, in a way allowed by the Heisenberg uncertainty principle <ref type="bibr">(12)</ref>. During LIGO's third observing run, frequency-independent squeezing was injected into the interferometer to reduce the imprecision noise while increasing the quantum back action noise <ref type="bibr">(13)</ref>. The injection of squeezed vacuum (denoted by subscript SQZ) into the output port of an interferometer ( <ref type="formula">14</ref>) modified its quantum noise relative to Eq. 3, to produce</p><p>where e -2r is the squeezing factor, the amount by which the injected quantum noise is squeezed relative to vacuum noise; f is the relative phase between the input squeezed field and the interferometer field (known as the squeeze angle); and</p><p>is the squeeze angle rotation due to the opto-mechanical response of the interferometer.</p><p>Frequency-dependent squeezed states (denoted by subscript FDSQZ) vary the input squeeze angle as a function of frequency f &#8594; f(W). They can be prepared by reflecting the frequency-independent squeezed state from a detuned and overcoupled Fabry-P&#233;rot cavity <ref type="bibr">(11,</ref><ref type="bibr">(15)</ref><ref type="bibr">(16)</ref><ref type="bibr">(17)</ref>. When the filter cavity linewidth is matched to</p><p>on the reflected squeezed vacuum states, which enables quantum noise reduction of e -2r at all frequencies (18)</p><p>At the frequency W SQL , this approach is predicted to reduce quantum noise below the SQL by a factor of e -2r</p><p>Experimental setup</p><p>We provide in Fig. <ref type="figure">1</ref> a simplified diagram of the LIGO interferometer <ref type="bibr">(19)</ref> during the fourth astrophysical observing run (O4), which began in 2023. It includes Fabry-P&#233;rot arm cavities formed by a pair of 40-kg mirrors to resonantly enhance strain sensitivity, input power recycling to increase the circulating laser power [and thus K W &#240; &#222;], and output signal extraction to broaden the detection bandwidth. Components of the squeezing system, comprising the squeezed vacuum source (squeezer) and the filter cavity, are also shown.</p><p>Squeezed vacuum was injected at the output port of the interferometer to reduce quantum noise <ref type="bibr">(20)</ref>. The LIGO squeezer generates frequency-independent squeezed vacuum states through spontaneous parametric downconversion of 532-nm photons in a bow-tie optical parametric amplifier cavity containing a nonlinear crystal <ref type="bibr">(13,</ref><ref type="bibr">21)</ref>. The 300-m filter cavity was controlled so that its resonance frequency is detuned with respect to the carrier frequency of the main laser, thus producing frequencydependent squeezing [f &#8594; f(W)] before injection into the interferometer <ref type="bibr">(11)</ref>. A movable beam diverter was placed in the squeezed vacuum beam path before injection into the interferometer. Squeezing could be injected or blocked by opening or closing the beam diverter.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Measuring quantum noise below the SQL</head><p>Our inferred quantum noise of the L1 detector operating with frequency-dependent squeezing is shown in Fig. <ref type="figure">2</ref>. We found that the quantum noise surpasses the SQL between 35 and 75 Hz, by a maximum of 3 dB near 50 Hz. Determining the squeezed quantum noise below 100 Hz is complicated by the presence of nonquantum (classical) noise that is a factor of two times greater in amplitude <ref type="bibr">(19)</ref>. We performed a two-step analysis to infer the squeezed quantum noise from measurements of the total noise. First, we inferred the classical noise by subtracting an unsqueezed quantum noise model from measurements of the total detector noise with squeezing disabled. The unsqueezed quantum noise model has several degenerate parameters. For example, the circulating laser power in the arm cavity and optical loss in the readout path have the same phenomenological effect on the imprecision noise. To constrain the parameter space, we experimentally set 11 constant squeezing angles f, because the quantum noise S SQZ depends strongly on f (Eq. 5), then found a single set of interferometer parameters that simultaneously matches the measured noise for every value of f. We performed Markov Chain Monte Carlo inference <ref type="bibr">(22)</ref> to determine the best-fitting set of parameters that match all 11 different squeeze angle datasets. Sensitivity measurements for the three values of f that dip below the SQL are shown in Fig. <ref type="figure">3</ref> (data for all 11 f values are shown in fig. <ref type="figure">S2</ref>). Compared with the simplified model presented above, this numerical noise model used for subtraction includes experimental degradations such as squeezing phase noise, optical loss, and mode-mismatch across the various cavities of the interferometer <ref type="bibr">(23)</ref><ref type="bibr">(24)</ref><ref type="bibr">(25)</ref>.</p><p>Squeezer LIGO main laser Y-arm cavity X-arm cavity Gravitational wave readout Faraday isolator Output mode cleaner Power recycling Signal recycling Filter cavity 1064 nm main laser Frequency-independent squeezed vacuum beam Frequency-dependent squeezed vacuum beam 532 nm pump laser </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>RESEARCH | RESEARCH ARTICLE</head><p>Second, we subtracted the classical noise estimate from subsequent measurements of the total detector noise with squeezing enabled to infer the squeezed quantum noise, which is our measurement of ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ffi S SQZ W &#240; &#222; p from Eq. 5. The two-step noise subtraction process assumes that classical noise remains identical between the unsqueezed and squeezed modes of operation. Any variations in classical noise between these modes are incorporated as estimation uncertainties. We used previously determined uncertainty propagation methods <ref type="bibr">(10)</ref> to estimate the total uncertainty budget, including statistical uncertainties from detector noise PSD estimation and nonstationary classical noise, and the systematic uncertainties from calibration and residual model errors <ref type="bibr">(22)</ref>.</p><p>Statistical uncertainties from PSD estimation and nonstationary classical noise <ref type="bibr">(26)</ref> limited estimates of low-frequency quantum noise. We interleaved multiple 20-min segments of unsqueezed and squeezed measurements to control for time variations of the classical noise. The total detector noise measured with 1 hour of combined data segments in the unsqueezed and squeezed configurations is shown in Fig. <ref type="figure">2</ref>. We found that the difference in the classical noise between segments (uncertainty from nonstationarity) is commensurate with the total uncertainty from 1 hour of PSD estimation with optimal frequency binning (fig. <ref type="figure">S4</ref>).</p><p>We performed a full derivation of the total uncertainty budget <ref type="bibr">(22)</ref>. The main systematic uncertainty arises from the real-time calibration process, which applies a known force to the mirror to actively modulate the strain and measure the instrument's response <ref type="bibr">(27,</ref><ref type="bibr">28)</ref>. For the data used in our measurements, the systematic uncertainties are less than 5% (fig. <ref type="figure">S4</ref>).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Squeezing with and without the filter cavity</head><p>We show in Fig. <ref type="figure">3</ref> L1 measurements of the inferred quantum noise with frequency-dependent squeezing and frequency-independent squeezing at three injected squeeze angles f. The data are presented as strain noise (Fig. <ref type="figure">3A</ref>) and as decibels of quantum noise reduction (Fig. <ref type="figure">3B</ref>) compared with no squeezing (the decibel noise reduction is defined as 20log <ref type="bibr">10</ref> ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ffi</p><p>). We also show in Fig. <ref type="figure">3</ref> numerical quantum noise models that use the best-fitting experimental parameters for the full interferometer and squeezer. The close agreement between the model curves and measured spectra supports the unsqueezed quantum noise model used for subtraction. We then extended the model to include the filter cavity parameters <ref type="bibr">(11)</ref>. The quantum noise model for frequency-dependent squeezing is consistent with the inferred quantum noise spectra.</p><p>Compared with frequency-independent squeezing, an ideal filter cavity would rotate the injected squeezing angle as a function of frequency,</p><p>, to reduce the quantum noise by a factor of e -2r at all frequencies, as in Eq. 6. That would provide a single configuration that reaches the envelope of sub-SQL quantum noises achievable by all frequencyindependent squeezing spectra. However, there is a discrepancy between the noise reduction achieved with frequency-independent squeezing and with the frequency-dependent squeezing provided by the filter cavity, especially between 20 and 200 Hz (Fig. <ref type="figure">3</ref>). The inclusion of the filter cavity reduces the quantum noise across a broader range of frequencies than squeezed light alone (Fig. <ref type="figure">3B</ref>) but not by as much as the theoretically predicted e -2r reduction of quantum noise at all frequencies.</p><p>We ascribe this nonoptimal performance to a mismatch between the SQL frequency and the filter cavity linewidth. Assuming a lossless cavity, an optimal filter cavity would have its half-width-at-half-maximum linewidth g FC and detuning d FC both matched to the SQL frequency, so that g FC &#188; d FC &#188; W SQL = ffiffi ffi 2 p (18). The installed filter cavity was designed to have g FC = 2p &#215; 42 Hz, by using an input coupler power transmissivity T in &#8776; 1000 parts per million (ppm) <ref type="bibr">(11)</ref> and assuming 60 ppm optical loss, to approximately match W SQL &#188; ffiffi ffi 2 p g FC &#188; 2p &#194; 59 Hz. However, our measurements indicate that the SQL frequency is W SQL = 2p &#215; 37 Hz, which is a factor of 1.6 less than that of the design.</p><p>We conclude that with frequency-dependent squeezing, the LIGO detectors operated with quantum-limited sensitivity that surpasses the SQL during astrophysical observing. With the squeezing rotation imparted by the current filter cavity, we show that squeezing directly increases detector sensitivity by 5.6 dB at kilohertz frequencies while yielding strain sensitivities that surpass the SQL around 50 Hz. This experimentally demonstrates a theoretically proposed improvement to gravitationalwave detectors <ref type="bibr">(9)</ref>. Our analysis was sufficient to model the quantum noise through the complex optical systems of the LIGO interferometer, which matches the experimental data across a wide range of input squeeze angles. The injection of quantum squeezing allowed us to probe the detector configuration and expand the astrophysical reach of gravitationalwave observations.</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="1" xml:id="foot_0"><p>Laser Interferometer Gravitational-Wave Observatory (LIGO) Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="2" xml:id="foot_1"><p>LIGO Livingston Observatory, Livingston, LA 70754, USA.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="1" xml:id="foot_2"><p>of 4 Downloaded from https://www.science.org at University of Florida Health Science Center on October 07,</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" n="2024" xml:id="foot_3"><p/></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_4"><p>Downloaded from https://www.science.org at University of Florida Health Science Center on October 07, 2024</p></note>