Title: Insights into Spectral Distortion and Nonlinearity in UV–Vis and Fluorescence Spectroscopy of Molecular Fluorophore Solutions: Effects of Cascading Optical Processes (Part IV)
Reproducibility and linearity are crucial benchmarks for any measurement technology. However, UV–vis and fluorescence spectral distortion and nonlinearity are prevalent, even in seemingly simple fluorescent solutions that comprise only one dissolved molecular fluorophore, without exogenous absorbing or scattering species. In this report, we introduce an analytical model for the quantification of fluorescence interference on UV–vis measurements and a conceptual model for mechanistically understanding the impacts of higher-order cascading optical processes on fluorescence measurements. The experimental UV–vis transmittance can be dominated by interfering fluorescence, even for fluorophore solutions with theoretical absorbance values far below the instrument’s linear dynamic range (LDR). Absorption-inner-filter-effect (aIFE) correction drastically improves the fluorescence LDR. However, the efficacy of aIFE correction hinges on two competing factors that strongly depend on the fluorophore’s optical properties: the degree of fluorescence interference in UV–vis and the significance of secondary or higher-order emission triggered by fluorophore absorption of emitted photons. Our research sheds light on the remarkable complexity of cascading optical processes that can occur even in the simplest fluorescent solutions. It emphasizes the necessity of critically evaluating optical spectroscopic measurements of fluorescent solutions to improve the reliability of analyzing and interpreting optical spectra. Moreover, it lays the groundwork for future development of methods capable of handling challenging samples that exceed the capabilities of the current tools.  more » « less
Award ID(s):
2203571
PAR ID:
10613220
Author(s) / Creator(s):
; ;
Publisher / Repository:
American chemical society
Date Published:
Journal Name:
Analytical Chemistry
Volume:
96
Issue:
33
ISSN:
0003-2700
Page Range / eLocation ID:
13542 to 13550
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Cascading optical processes involve sequential photon–matter interactions triggered by the same individual excitation photons. Parts I and II of this series explored cascading optical processes in scattering-only solutions (Part I) and solutions with light scatterers and absorbers but no emitters (Part II). The current work (Part III) focuses on the effects of cascading optical processes on spectroscopic measurements of fluorescent samples. Four types of samples were examined: (1) eosin Y (EOY), an absorber and emitter; (2) EOY mixed with plain polystyrene nanoparticles (PSNPs), which are pure scatterers; (3) EOY mixed with dyed PSNPs, which scatter and absorb light but do not emit; and (4) fluorescent PSNPs that are simultaneous light absorbers, scatterers, and emitters. Interference from both forward scattered and emitted photons can cause nonlinearity and spectral distortion in UV–vis extinction measurements. Sample absorption by nonfluorogenic chromophores reduces fluorescence intensity, while the effect of scattering on fluorophore fluorescence is complicated by several competing factors. A revised first-principles model is developed for correlating the experimental fluorescence intensity with the sample absorbance in solutions containing both scatterers and absorbers. The optical properties of fluorescent PSNPs of three different sizes were systematically investigated by using integrating-sphere-assisted resonance synchronous spectroscopy, linearly polarized resonance synchronous spectroscopy, UV–vis, and fluorescence spectroscopy. The insights and methodology provided in this work should help improve the reliability of spectroscopic analyses of fluorescent samples, where the interplay among light absorption, scattering, and emission can be complex. 
    more » « less
  2. UV–vis spectrophotometry and spectrofluorometry are indispensable tools in education, research, and industrial process controls with widespread applications in nanoscience encompassing diverse nanomaterials and fields. Nevertheless, the prevailing spectroscopic interpretations and analyses often exhibit ambiguity and errors, particularly evident in the nanoscience literature. This analytical chemistry Perspective focuses on fostering evidence-based data interpretation in experimental studies of materials’ UV–vis absorption, scattering, and fluorescence properties. We begin by outlining common issues observed in UV–vis and fluorescence analysis. Subsequently, we provide a summary of recent advances in commercial UV–vis spectrophotometric and spectrofluorometric instruments, emphasizing their potential to enhance scientific rigor in UV–vis and fluorescence analysis. Furthermore, we propose potential avenues for future developments in spectroscopic instrumentation and measurement strategies, aiming to further augment the utility of optical spectroscopy in nano research for samples where optical complexity surpasses existing tools. Through a targeted focus on the critical issues related to UV–vis and fluorescence properties of nanomaterials, this Perspective can serve as a valuable resource for researchers, educators, and practitioners. 
    more » « less
  3. A 1,2,3-triazole-based chemosensor is used for selective switching in logic gate operations through colorimetric and fluorometric response mechanisms. The molecular probe synthesized via “click chemistry” resulted in a non-fluorescent 1,4-diaryl-1,2,3-triazole with a phenol moiety (PTP). However, upon sensing fluoride, it TURNS ON the molecule’s fluorescence. The TURN-OFF order occurs through fluorescence quenching of the sensor when metal ions, e.g., Cu2+, and Zn2+, are added to the PTP-fluoride ensemble. A detailed characterization using Nuclear Magnetic Resonance (NMR) spectroscopy in a sequential titration study substantiated the photophysical characteristics of PTP through UV-Vis absorption and fluorescence profiles. A combination of fluorescence OFF-ON-OFF sequences provides evidence of 1,2,3-triazoles being controlled switches applicable to multimodal logic operations. The “INH” gate was constructed based on the fluorescence output of PTP when the inputs are F− and Zn2+. The “IMP” and “OR” gates were created on the colorimetric output responses using the probe’s absorption with multiple inputs (F− and Zn2+ or Cu2+). The PTP sensor is the best example of the “Write-Read-Erase-Read” mimic. 
    more » « less
  4. Louis, Matthieu (Ed.)
    Imaging neural activity in a behaving animal presents unique challenges in part because motion from an animal’s movement creates artifacts in fluorescence intensity time-series that are difficult to distinguish from neural signals of interest. One approach to mitigating these artifacts is to image two channels simultaneously: one that captures an activity-dependent fluorophore, such as GCaMP, and another that captures an activity-independent fluorophore such as RFP. Because the activity-independent channel contains the same motion artifacts as the activity-dependent channel, but no neural signals, the two together can be used to identify and remove the artifacts. However, existing approaches for this correction, such as taking the ratio of the two channels, do not account for channel-independent noise in the measured fluorescence. Here, we present Two-channel Motion Artifact Correction (TMAC), a method which seeks to remove artifacts by specifying a generative model of the two channel fluorescence that incorporates motion artifact, neural activity, and noise. We use Bayesian inference to infer latent neural activity under this model, thus reducing the motion artifact present in the measured fluorescence traces. We further present a novel method for evaluating ground-truth performance of motion correction algorithms by comparing the decodability of behavior from two types of neural recordings; a recording that had both an activity-dependent fluorophore and an activity-independent fluorophore (GCaMP and RFP) and a recording where both fluorophores were activity-independent (GFP and RFP). A successful motion correction method should decode behavior from the first type of recording, but not the second. We use this metric to systematically compare five models for removing motion artifacts from fluorescent time traces. We decode locomotion from a GCaMP expressing animal 20x more accurately on average than from control when using TMAC inferred activity and outperforms all other methods of motion correction tested, the best of which were ~8x more accurate than control. 
    more » « less
  5. Abstract Dissolved organic matter (DOM) impacts the structure and function of aquatic ecosystems. DOM absorbs light in the UV and visible (UV–Vis) wavelengths, thus impacting light attenuation. Because absorption by DOM depends on its composition, UV–Vis absorbance is used to constrain DOM composition, source, and amount. Ferric iron, Fe(III), also absorbs in the UV–Vis; when Fe(III) is present, DOM-attributed absorbance is overestimated. Here, we explore how differing behavior of DOM and Fe(III) at the catchment scale impacts UV–Vis absorbance and evaluate how system-specific variability impacts the effectiveness of existing Fe(III) correction factors in a temperate watershed. We sampled five sites in the Connecticut River mainstem bi-weekly for ~ 1.5 years, and seven sites in the Connecticut River watershed once during the summer 2019. We utilized size fractionation to isolate the impact of DOM and Fe(III) on absorbance and show that variable contributions of Fe(III) to absorbance at 254 nm (a 254 ) and 412 nm (a 412 ) by size fraction complicates correction for Fe(III). We demonstrate that the overestimation of DOM-attributed absorbance by Fe(III) is correlated to the Fe(III):dissolved organic carbon concentration ratio; thus, overestimation can be high even when Fe(III) is low. a 254 overestimation is highly variable even within a single system, but can be as high as 53%. Finally, we illustrate that UV-Vis overestimation might impart bias to seasonal, discharge, and land-use trends in DOM quality. Together, these findings argue that Fe(III) should be measured in tandem with UV–Vis absorbance for estimates of CDOM composition or amount. 
    more » « less