			<titleStmt><title level='a'>Laser‐Induced Graphene‐Assisted Patterning and Transfer of Silver Nanowires for Ultra‐Conformal Breathable Epidermal Electrodes in Long‐Term Electrophysiological Monitoring</title></titleStmt>
			<publicationStmt>
				<publisher>Wiley</publisher>
				<date>03/10/2025</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10617172</idno>
					<idno type="doi">10.1002/adfm.202504481</idno>
					<title level='j'>Advanced Functional Materials</title>
<idno>1616-301X</idno>
<biblScope unit="volume"></biblScope>
<biblScope unit="issue"></biblScope>					

					<author>Jiuqiang Li</author><author>Senhao Zhang</author><author>Jun Zhong</author><author>Benkun Bao</author><author>Kai Guo</author><author>Yingying Zhang</author><author>Kerong Yang</author><author>Yao Tong</author><author>Donghai Qiu</author><author>Hongbo Yang</author><author>Huanyu Cheng</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[<title>Abstract</title> <p>Nanomaterial‐based stretchable electronics composed of conductive nanomaterials in elastomer can seamlessly integrate with human skin to imperceptibly capture electrophysiological signals. Despite the use of transfer printing to form embedded structures, it remains challenging to facilely and stably integrate conductive nanomaterials with thin, low‐modulus, adhesive elastomers. Here, a facile‐yet‐simple laser‐induced graphene (LIG)‐assisted patterning and transfer method is demonstrated to integrate patterned silver nanowires onto an ultra‐low modulus silicone adhesive as ultra‐conformal epidermal electrodes. The resulting thin epidermal electrodes of ≈50µm exhibit a low sheet resistance (0.781 Ω sq<sup>−1</sup>), tissue‐like Young's modulus (0.53MPa), strong self‐adhesion, and excellent breathability. The breathable electrodes dynamically conformed to the skin with low contact impedance allow for long‐term, high‐fidelity monitoring of electrophysiological signals in complex environments (even during exercise and heavy sweating). Moreover, the LIG‐assisted transfer can provide a robust interface to establish a stable connection between the soft electrodes and rigid hardware. The large‐scale fabrication further provides an eight‐channel electromyography system combined with a deep learning algorithm for gesture classification and recognition with remarkable accuracy (95.4%). The results from this study also provide design guidelines and fabrication methods of the next‐generation epidermal electronics for long‐term dynamic health monitoring, prosthetic control, and human‐robot collaborations.</p>]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">Introduction</head><p>Epidermal electronics, known for their skin-like properties, refer to electronic devices mounted on the skin with stable DOI: 10.1002/adfm.202504481 physiological signal outputs, which play a vital role in health monitoring, disease diagnosis, and human-machine interfaces. <ref type="bibr">[1]</ref> Compared with traditional rigid wearable devices, epidermal electronics with a modulus close to that of skin could deform with skin to maintain good conformal contact during natural motions/deformations, which reduces motion artifacts and allows for continuous, long-term monitoring while minimizing discomfort. <ref type="bibr">[2]</ref> Electrophysiological signals such as electrocardiograms (ECG), electromyograms (EMG), electrooculograms (EOG), electroencephalograms (EEG), etc., generated during human muscular activities, contain a wealth of physiological information that reflects the body's health status. <ref type="bibr">[3]</ref> Longterm monitoring of these signals offers a wider temporal perspective, allowing for the acquisition of more comprehensive health information and enhancing the ability to detect transient and subtle anomalies, which can improve the diagnostic accuracy of related diseases (such as epilepsy, <ref type="bibr">[4]</ref> atrial fibrillation, <ref type="bibr">[5]</ref> and muscle atrophy). <ref type="bibr">[6]</ref> The non-invasive monitoring of epidermal electrophysiological signals typically relies on the use of bioelectrodes mounted on the skin surface. <ref type="bibr">[7]</ref> The most commonly used Ag/AgCl electrodes for electrophysiological monitoring are associated with limitations such as dehydration, high skin contact impedance, skin inflammation, and performance degradation from motion artifacts. Therefore, they are unsuitable for accurate electrophysiological monitoring under complex conditions such as long-term monitoring and exercise accompanied by heavy sweating. <ref type="bibr">[8]</ref> To obtain high-quality electrophysiological signals with low motion artifacts in these complex situations, dry electrodes with high conformability and breathability, along with low contact impedance, are highly desirable. <ref type="bibr">[9]</ref> Good conformality facilitates a seamless skin/electrode interface to establish a stable and unhindered signal pathway, which can be realized by reduced bending stiffness (from decreased thickness and modulus). The stable performance over motions often hinges on strong adhesion at the electrode/skin interface. <ref type="bibr">[10]</ref> In addition, inevitable perspiration during long-term monitoring triggers signal distortion due to adhesion failure at the skin/electrode interface, and the residual moisture further causes skin irritation and user compliance issues. <ref type="bibr">[11]</ref> Furthermore, a low-impedance skin-electrode interface is also crucial for accurate monitoring of electrophysiological signals, which usually comes from the high conductivity of the electrode. <ref type="bibr">[12]</ref> Therefore, it has been the central focus to develop epidermal electrodes with minimized thickness and modulus, enhanced breathability, conductivity, and excellent adhesion (along with easy removal if possible).</p><p>Although conductive patterns can be directly formed on the low-modulus elastomer surface with 3D printing or spray coating, <ref type="bibr">[13]</ref> they often suffer from weak interfacial adhesion and require complex surface treatments to avoid delamination. <ref type="bibr">[14]</ref> The ultra-thin metal film patterned into a mesh layout by photolithography or laser cutting can be subsequently transferred and printed onto thin soft, stretchable substrates, <ref type="bibr">[15]</ref> but the interface is still not sufficiently strong and the fabrication also needs to use sophisticated fabrication equipment and complex surface functionalization. <ref type="bibr">[16]</ref> In addition, the connection between electrodes and rigid data acquisition systems with commercial conductive pastes (e.g., anisotropic conductive film cables and silver paste) often suffers from interfacial failure upon deformation due to mechanical mismatch. <ref type="bibr">[17]</ref> Transfer printing technology often relies on pre-deposition on a donor substrate and subsequent physical transfer, <ref type="bibr">[18]</ref> which allows the conductive nanomaterial network to be embedded into the polymer matrix for enhanced mechanical stability. <ref type="bibr">[19]</ref> The conductive nanomaterial network with good electrical conductivity and stretchability is crucial for establishing a stable, low-impedance skin/electrode interface. <ref type="bibr">[20]</ref> Compared with the other types of conductive nanomaterials such as nanoparticles or nanosheets, nanowires such as AgNWs with large aspect ratios can exhibit high metallic conductivity at low percolation thresholds for improved optical transparency. <ref type="bibr">[21]</ref> As a result, the composite features a large surface coverage of the adhesive polymer for enhanced adhesion and facile connection with rigid data acquisition modules in a plug-and-play manner. It is relatively easy to completely transfer the AgNWs network to high-modulus, low-adhesion substrates such as poly(methyl methacrylate), polyimide (PI), polyvinyl alcohol (PVA), and poly(dimethylsiloxane) (PDMS). However, van der Waals forces between the deposited AgNWs network and the donor substrate increase the difficulty of the transfer, <ref type="bibr">[22]</ref> where the target ultra-thin, low-modulus soft elastomers often cannot supply sufficient gripping force to overcome the van der Waals forces, causing irreversible damage to the AgNWs network with low transferring yields. Thus, successful complete transfer often requires exploring the target elastomer with high modulus and reduced adhesion, leading to compromised conformality.</p><p>Efforts to address this challenge led to 1) chemical modifying the elastomer to facilitate the formation of robust chemical bonding with the AgNWs and 2) tuning the rigidity of the elastomer for improved gripping force during transfer. The former can include Ag-N bonding between AgNWs and bipyridine-modified PDMS or the Triton-X-doped PDMS, <ref type="bibr">[19b,23]</ref> but the limited material choices and sophisticated modification methods present challenges for large-scale industrialization. The representative effort in the latter exploits a cryo-transfer technique that freezes PDMS in liquid nitrogen (N 2 ) with a temporarily increased modulus. <ref type="bibr">[24]</ref> As the PDMS returns to its initial low-modulus state when attached to the skin, the epidermal electrode with the entire Ag-NWs network successfully transferred to the ultra-thin (8.4 &#956;m) PDMS exhibits a sheet resistance of 13.2 &#937; sq -1 and conforms to the skin for monitoring electrophysiological signals. Similarly, silk fibroin with tunable rigidity through changes in relative humidity can also transfer stretchable metal networks with high yields. <ref type="bibr">[25]</ref> However, the complex operation and strict environmental requirements make it difficult to be widely used.</p><p>In addition, customized high-density surface electromyography (sEMG) and full-scalp EEG measurements require complex patterning of electrodes over a large scale. <ref type="bibr">[2a,26]</ref> Although mask spraying and screen printing can be exploited, <ref type="bibr">[14,</ref><ref type="bibr">27]</ref> these two commonly used patterning methods have low material utilization rates and usually require customized masks, which often cannot be reused due to sample/ink residuals after use, leading to significantly increased preparation time and costs. Other patterning techniques such as maskless inkjet printing can directly print AgNWs on target elastomer, <ref type="bibr">[28]</ref> but ink composition and rheology need intricate optimization and nozzle clogging also hinders repeated use. Thus, it is essential to develop AgNWs transfer technique that is scalable, universal, easy to pattern, and low-cost yet highly efficient.</p><p>This work explores laser-induced graphene (LIG)-assisted transferring and patterning of the AgNWs network onto an ultrathin, breathable, self-adhesive, low-modulus stretchable substrate to provide epidermal electrodes for ultra-long-term, dynamic monitoring of electrophysiological signals in complex environments (Figure <ref type="figure">1a</ref>). Due to its lower contact angle with solvents and weaker van der Waals forces with the AgNWs network, the patterned porous LIG allows facile transfer of the patterned AgNWs network onto the soft, adhesive stretchable substrate through a simple sticking and peeling-off process with near 100% yield. The resulting electrodes with the patterned AgNWs network on the representative substrate that combines styrene-ethylene-butylene-styrene block copolymer (SEBS) with Silbione of extremely low modulus (7 kPa) and strong adhesion (80 Nm -1 ) can conform to the skin with low contact impedance and reduced motion artifacts (Figure <ref type="figure">1b-i</ref>). The entire preparation process is simple yet efficient and suitable for the preparation of large-area epidermal electrode arrays with complex patterns. With periodic perforation provided by the same laser, the porous substrate together with the AgNWs network provides the resulting epidermal electrodes with breathable properties and reduced effective modulus to form excellent dynamic conformal contact with the skin and maintain stable adhesion even during sweating (Figure <ref type="figure">1b</ref>-ii). In addition, the adhesive epidermal electrode can facilely establish a stable connection with rigid data acquisition modules by simple pressing without using adhesives/pastes (Figure <ref type="figure">1b</ref>-iii). As a result, the porous SEBS-Silbione-AgNWs (P-SSA) epidermal electrodes exhibit outstanding long-term, wireless, and dynamic monitoring of high-quality electrophysiological signals in complex real-world scenarios. The P-SSA epidermal electrodes configured into a two by eight array and combined with a deep learning algorithm further result in an 8-channel EMG system for gesture recognition of eight common gestures with an excellent accuracy rate of 95.4%. The design, fabrication, and application of the P-SSA epidermal electrodes pave the way for future imperceptible electronics for high-precision, ultra-long-term monitoring of electrophysiological and other vital signals for early disease diagnostics, timely treatment evaluations, and accurate prosthetic controls.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">Results and Discussion</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1.">Skin-Conformal Epidermal Electrodes Prepared by LIG-Assisted Transfer Printing</head><p>Compared to the other methods that only focus on the changes in the target elastomer, we modulate the donor substrate for simultaneous transfer and patterning with improved efficiency. Inspired by previous studies that explore graphene with a weak van der Waals interface to assist the transfer of metal films, <ref type="bibr">[22]</ref> patterned hydrophilic and porous LIG prepared from a singlestep laser scribing over a large scale can assist in the almost complete transfer (near 100%) and easy patterning of AgNWs without other environment and equipment requirements. Compared to traditional chemical vapor deposition (CVD) and graphite exfoliation methods used to prepare graphene, <ref type="bibr">[29]</ref> the fabrication method from this study also offers the advantages of simplicity, lower cost, and easy-to-pattern. The fabrication starts with i) the preparation of an ultra-thin, breathable, self-adhesive stretchable substrate and ii) simultaneous LIG-assisted patterning of AgNWs network, followed by iii) transfer printing of patterned AgNWs from LIG onto the stretchable substrate via a simple mechanical peeling (Figure <ref type="figure">1c</ref>).</p><p>The stretchable substrate with a bi-layered design consists of an elastomeric SEBS with excellent elasticity on top of a lowmodulus Silbione adhesive. The top ultra-thin, non-adhesive SEBS film provides mechanical support for conductive AgNWs while ensuring easy removal from the donor release paper after applying to the skin, whereas the bottom Silbione ensures sufficient adhesion strength to the skin for long-duration wear. The donor release paper serves as a temporary support layer to prevent the electrical failure of the AgNWs-elastomer conductive network during the transfer printing (removed after skin attachment). In addition, micro perforations of circular hole arrays with a diameter of 0.16 mm and a spacing of 0.64 mm in the substrate obtained with the 10.6 &#956;m CO 2 laser enhance the permeability of the air and water molecules. Next, patterned porous LIG prepared on commercial polyimide (PI) films using the same CO 2 laser has more polar bonds (C&#9472;O, C&#9552;O) and other oxygenated groups, <ref type="bibr">[30]</ref> exhibiting a smaller ethanol contact angle compared to PI (Figure <ref type="figure">S1</ref>, Supporting Information). Therefore, the AgNWs dispersion (diameter of 90 nm and length of 60 &#956;m) in ethanol drop-coated onto the LIG pattern would be dispersed uniformly on the entire LIG pattern without flowing onto the PI. As ethanol evaporates, a freestanding AgNWs network with the same pattern as the LIG forms on the surface and can be easily exfoliated mechanically due to the weak van der Waals surface and porous nature of the LIG. Lastly, applying the previously prepared stretchable substrate with the Silbione adhesive facing the AgNWs/LIG surface followed by a gentle pressure embeds the AgNWs network into the top surface of the elastomer. Moreover, the low modulus of the top Silbione and uneven porous surface of LIG is favorable for the semi-embedding of AgNWs during the LIG-assisted transfer, establishing a stable electrical connection to resist delamination failure during motion (Figure <ref type="figure">S2</ref>, Supporting Information). The AgNWs network with a natural porous structure (Figure <ref type="figure">S3</ref>, Supporting Information) combined with the perforated substrate yields ultra-conformal and breathable epidermal electrodes.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.">Mechanism of LIG-Assisted Transfer Printing and Patterning of the AgNWs Network</head><p>Characterizations of the microstructures of the AgNWs/LIG and AgNWs/PI interfaces help elucidate the mechanism of LIGassisted transfer. The scanning electron microscope (SEM) im-age reveals a clear boundary and line contacts between the Ag-NWs and the LIG (Figure <ref type="figure">2a-i</ref>) due to the van der Waals surface of graphene and thus no interfacial products. Furthermore, the wrinkles and porous structure of the LIG surface further reduce the contact area with the AgNWs and lower the interfacial energy, resulting in a high transfer yield (Figure <ref type="figure">2b-i</ref>). In contrast, the interface between the PI and the AgNWs exhibits fuzzy boundaries and face contacts (Figure <ref type="figure">2a</ref>-ii), which probably results from the dispersant (polyvinylpyrrolidone, PVP) of the AgNWs solution deposited at the interface to form a semicircular shape in the cross-sectional view (Figure <ref type="figure">2b</ref>-ii). Additionally, the smooth surface of the PI provides a larger contact area with the AgNWs to increase the interfacial energy and adhesion, presenting difficulty in transfer.</p><p>The easily detachable amorphous carbon on the LIG surface also facilitates the transfer of the AgNWs from LIG to the stretchable SEBS-Silbione substrate (Figure <ref type="figure">2c</ref>). Compared with no carbon particles on the AgNWs transferred from PI, carbon particles are evident on the surface of the AgNWs transferred from LIG or even the transferred LIG (in the control without AgNWs on LIG) (Figure <ref type="figure">2d-i</ref>). Raman spectra of the transferred surfaces reveal characteristic D peak (&#8776;1350 cm -1 ), G peak (&#8776;1580 cm -1 ), and 2D peak (&#8776;2700 cm -1 ) for the transferred LIG, along with the increased width of D and G peaks but the absence of the 2D peak to indicate amorphous carbon for the AgNWs transferred from LIG (Figure <ref type="figure">2d</ref>-ii). <ref type="bibr">[29a]</ref> In contrast, the AgNWs transferred from PI do not exhibit any characteristic peaks of graphene or amorphous carbon. In the survey of energy dispersive X-ray spectroscopy (EDS), the transferred LIG surfaces display decreased energy of the C peak and the absence of the Ag peak. Taken together with the presence of Ag and C elements on the transferred SEBS-Silbione elastomer surface (Figure <ref type="figure">2e-i</ref>), the results indicate that the AgNWs and part of the amorphous carbon have been successfully transferred from the LIG surface to the elastomer surface. Moreover, the elemental mapping images (Figure <ref type="figure">2e</ref>-ii) clearly show a uniform distribution of the C element on the elastomer surface. Meanwhile, when amorphous carbon is removed from the LIG surface with repeated taping (Figure <ref type="figure">2f</ref>), the yield of the LIG-assisted transfer calculated by counting the AgNWs on the LIG surface before and after the transfer is sharply decreased from 95.7 &#177; 1.5% to 23.6 &#177; 12.7% (Figure <ref type="figure">2g</ref>; Figures <ref type="figure">S4</ref> and <ref type="figure">S5</ref>, Supporting Information). Collectively, the above results confirm the critical role of the amorphous carbon on the LIG surface in facilitating the transfer process of AgNWs.</p><p>The low interfacial energy between porous LIG and AgNWs, together with the easily detachable amorphous carbon on the LIG surface, can result in a high transfer yield at room temperature for the LIG-assisted transfer. Compared with a partial transfer (also with damage) of the AgNWs deposited on PI, AgNWs deposited on LIG are almost completely damage-free transferred to the soft SEBS-Silbione substrate (Figure <ref type="figure">S6</ref>, Supporting Information), and the yield of the LIG-assisted transfer is significantly higher than 30.8 &#177; 4.2% (or 16.2 &#177; 8.1%) for the direct transfer from the PI (or glass) (Figure <ref type="figure">S7</ref>, Supporting Information), which demonstrates the salient advantages of LIG-assisted transfer. The increase in the laser flux varies the surface morphology of the induced graphene: incomplete patterning, laser-induced graphene, laser-induced graphene fibers (LIGF), carbon nanoparticles, and complete ablation (Figure <ref type="figure">S8</ref>, Supporting Information). <ref type="bibr">[31]</ref> The  morphology of incomplete patterning, carbon nanoparticles, and complete ablation is accompanied by the loss of porous graphene structure and amorphous carbon to result in obvious residues of AgNWs. Besides, the presence of some AgNWs on the back of LIGF makes it difficult to be in contact with the SEBS-Silbione substrate (Figure <ref type="figure">S9</ref>, Supporting Information) resulting in incomplete transfer (Figure <ref type="figure">2h-i</ref>). However, the LIG fabricated from various laser parameters features a consistently high transfer yield, which reaches &#8776;99.9% as the deposition density of AgNWs increases to 40 &#956;L cm -2 (Figure <ref type="figure">2h</ref>-ii), indicating the versatility of the LIG-assisted patterning and transfer method for AgNWs (Figures <ref type="figure">S10</ref> and <ref type="figure">S11</ref>, Supporting Information).</p><p>In addition, the pattern LIG with a smaller ethanol contact angle also facilitates the AgNWs patterning processing without the mask. Furthermore, linear pattern arrays with varying line widths and spacings fabricated from the CO 2 laser demonstrate mini-mum achievable feature resolution with a line width of 150 &#956;m and a spacing of 100 &#956;m (Figure <ref type="figure">S12</ref>, Supporting Information).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Mechanical, Electrical, and Breathable Properties of Skin-Conformal Epidermal Electrodes</head><p>The conformal contact of the epidermal electrode to the skin without constraining the natural motions is demonstrated by attaching the SSA composite to a finger joint with a tight fit to the wrinkled skin without any visible detachment (Figure <ref type="figure">3a</ref>). <ref type="bibr">[32]</ref> The use of a 50 &#956;m-thick stretchable substrate (Figure <ref type="figure">S13</ref>, Supporting Information) with low-modulus and strong adhesion also allows transfer of a "SIBET"-shaped AgNWs network onto the forearm to form intimate contact with the skin and follow the deformations/motions of the skin (e.g., stretching, compression, and twisting) (Video S1, and Figure <ref type="figure">S14</ref>, Supporting Information). Compared with a medical dressing (3m Tegaderm) that generates large wrinkles due to poor conformability and modulus mismatch with the skin, the SSA composite forms intimate contact with the skin (Figure <ref type="figure">3b</ref>). In addition, there is no skin irritation after continuous wearing of P-SSA electrodes for 7 days due to the high biocompatibility (Figure <ref type="figure">S15</ref>, Supporting Information). In conclusion, the thin, lower-modulus, stretchable P-SSA electrode results in a minimal constraint on skin deformation to provide a more comfortable wearing experience with almost no foreign body sensation.</p><p>A strong and stable adhesion at the electrode/skin interface is key to ensure low contact impedance for accurate acquisition of electrophysiological signals, especially under movements and skin motions/deformations. The standard 90-degree peeling test of the epidermal electrode from dry human skin at a speed of 30 mm min -1 is carried out to evaluate the adhesion strength. Although the adhesion (40 N/m) of the SSA composite to the skin is only half of that (80 N m -1 ) of the SEBS-Silbione stretchable substrate (Figure <ref type="figure">3c</ref>), it is still larger than most previously reported electrodes (Table <ref type="table">S1</ref>, Supporting Information). Meanwhile, the practical use of the electrode pattern often explores 25% surface coverage over the entire substrate area to result in a higher adhesion of 70 N m -1 . Such high adhesion allows the epidermal electrodes to stably adhere to the skin, but there is no residue when removed (Figure <ref type="figure">S16</ref>, Supporting Information) due to the mechanical robustness of the bi-layered design. The stress-strain curve of the SSA composite (Figure <ref type="figure">3d</ref>) reveals a lower overall modulus (0.53 MPa) (calculated from the linear range up to 5% strain) and higher stretchability (406%) (Figure <ref type="figure">3e</ref>). Compared to SBES, Silbione, and SEBS-Silbione films, the SSA composite exhibits almost the same mechanical properties as the SEBS-Silbione composite, which shows decreased Young's modulus and increased stretchability over SEBS due to the use of Silbione. The favorable mechanical properties of the SSA composite allow it to maintain stable contact and adhesion to the skin during large deformation without constraining the skin motion.</p><p>The low sheet resistance of the electrode and good contact with the skin contribute to the reduced electrode/skin contact impedance for high-performance recording and stimulation. <ref type="bibr">[12,</ref><ref type="bibr">33]</ref> The sheet resistance of the AgNWs network in an 8 mm &#215; 8 mm square measured using a four-point probe drops sharply from 70 to 0.781 &#937; sq -1 as the AgNWs content increases from 2 to 10 &#956;L cm -2 (Figure <ref type="figure">S17</ref>, Supporting Information). Meanwhile, the transparency only decreases slightly from 72.10% to 64.95% (Figure <ref type="figure">3f</ref>). Additionally, the relative resistance change under stretching shows a larger variation for the sample with increased concentration of AgNWs from 4 to 40 &#956;L cm -2 (Figure <ref type="figure">S18</ref>, Supporting Information). Considering a larger variation in the relative resistance change is more likely to introduce motion artifacts, the AgNWs content of 10 &#956;L cm -2 exhibits a balance performance with high transparency (&#8776;64.95%), low sheet resistance (&#8776;0.781 &#937; sq -1 ), and small relative resistance changes upon stretching. Therefore, the concentration of 10 &#956;L cm -2 is chosen in the following investigations unless otherwise specified. As the vapor permeability of wearable electrodes is key to avoiding skin inflammation and adhesion failure during long-term use, <ref type="bibr">[34]</ref> the WVTR test is carried out to evaluate the vapor permeability of the electrodes. The P-SSA electrode with microperforation array exhibits WVTR of 8.84 mg&#8226;cm -2 &#8226;h -1 , which is almost the same as that of the open bottle (9.29 mg&#8226;cm -2 &#8226;h -1 ) at 25 &#176;C and 25% relative humidity and much larger than that of the non-porous SSA electrode (without microperforation) and 3 m Tegaderm (Figure <ref type="figure">3g</ref>). In addition, the water vapor transmission rate (WVTR) of the P-SSA electrode is higher than the trans-epidermal water loss during varying levels of exercise (&#8776;0.6-6.6 mg&#8226;cm -2 &#8226;h -1 ). <ref type="bibr">[35]</ref> As a result, the electrode does not affect sweat evaporation and is suitable for electrophysiological monitoring during exercise accompanied by heavy sweating.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Application of Skin-Conformal Epidermal P-SSA Electrodes for ECG Monitoring</head><p>Two P-SSA working electrodes placed on the inner wrists of the right and left arms, together with another P-SSA ground electrode on the left foot, record ECG signals over time in complex environmental conditions (Figure <ref type="figure">4a</ref>). As the stable and low-impedance skin-electrode interface supports long-term highquality monitoring of electrophysiological signals, <ref type="bibr">[36]</ref> the skin contact impedance of the P-SSA electrode has been investigated under varying intricate conditions (e.g., dry, sweaty, and stretched) (Figure <ref type="figure">4b</ref>). Compared with the commercial Ag/AgCl gel electrode, the P-SSA electrodes exhibit lower areal contact impedance in both dry and wet conditions, along with less variation during skin deformation such as stretching. The obtained ECG signal with distinct features of P-wave, QRS-complex, and Twave (Figure <ref type="figure">S19</ref>, Supporting Information) clearly matches that from the commercial gel electrode even under different motions such as finger pressing, finger stretching, and forearm movements (Figure <ref type="figure">4c-i</ref>). Compared with the commercial gel electrodes, the P-SSA electrodes exhibit more stable ECG signals with a higher signal-to-noise ratio (SNR) (Figure <ref type="figure">4c</ref>-ii), especially during finger stretching and forearm movements. The improved tolerance to the dynamic interference from the P-SSA electrodes results from its stable conformal contact with the skin. The excellent breathability also allows the use of P-SSA electrodes for long-term continuous monitoring of the ECG signals over 7 days (Figure <ref type="figure">4d-i</ref>), with distinguishable PQRST waveform and only a slight decrease from 18.38 to 17.43 in SNR (Figure <ref type="figure">4d</ref>-ii). Moreover, the ECG signals measured by P-SSA electrodes stored for 200 days in the ambient conditions still maintain a high SNR (&#8776;18.38) that is comparable to the freshly prepared (&#8776;18.64), which is attributed to its consistent high adhesive force (&#8776;31 N m -1 ) and stretchability (&#8776;404%) (Figure <ref type="figure">S20</ref>, Supporting Information) to ensure a stable electrode-skin interface. In addition, the backside of SEBS-Silbione with a high water contact angle of &#8776;88&#176;also facilitates the use of P-SSA electrodes in water with high SNR (Figure <ref type="figure">S21</ref> and Video S2, Supporting Information). The above results build a strong foundation for the P-SSA electrode's long-term usage in daily life with complex conditions, but a stable connection with the data acquisition (DAQ) system is still a challenge.</p><p>Modulus mismatch between soft P-SSA electrodes and the rigid DAQ hardware is prone to debonding due to the stress concentration. As the LIG-assisted transfer can integrate Ag-NWs onto different receiving substrates with varying moduli, a gradient modulus design facilely achieved by exploiting Ag-NWs transferred onto 3m Tegaderm (TAg) as a composite with intermediate modulus (&#8776;26.7 MPa) between the P-SSA (&#8776;0.53 MPa) electrode and rigid hardware (Figure <ref type="figure">4e-i</ref>). The inherently stretchable, adhesive, conductive TAg-SSA interface (Figure <ref type="figure">S22</ref>, Supporting Information) can establish a stable connection between soft P-SSA and rigid Cu pad of the DAQ system in a plug-and-play manner, even upon skin motions and deformations (Figure <ref type="figure">S23</ref>, Supporting Information). The adhesive polymer with a large surface coverage at the pattern area provides high adhesion strength as revealed by the SEM image (Figure <ref type="figure">4e</ref>-ii), whereas the semi-embedded structure of AgNWs forms the continuous conductive pathway. As a result, the ECG signals collected by the P-SSA electrodes are immune to motion artifacts (Figure <ref type="figure">4e</ref>-iii). Taken together with the plug-and-play TAg-SSA interface, the ECG signal quality is well maintained during repeated "peeling-and-reattaching" cycles (Figure <ref type="figure">S24</ref>, Supporting Information).</p><p>Three P-SSA electrodes self-adhered on the chest and connected to the wireless DAQ system (BioBox M2, Sibet CAS) by the TAg-SSA interface with a gradient modulus allows wireless, continuous long-term ECG recording during varying activities and events in daily life (Video S3, Supporting Information). While a mild baseline shift is observed during high-intensity exercise that generates heavy sweating and skin deformation, the measured raw ECG signals without filtering still exhibit wellpreserved characteristic peaks and features, indicating the negligible effect of sweating and motion artifacts on ECG monitoring. Therefore, the integrated sensing system with good breathability, excellent dynamic skin conformality, and stable TAg-SSA interface facilitates wireless, long-term, continuous ECG monitoring over 21 h (Figure <ref type="figure">4f</ref>). While direct coating of the AgNWs-ethanol solution on the porous SEBS-silicone substrate also prepares the electrode, it is prone to crack formation and unable to record stable ECG signals during skin deformation (Figure <ref type="figure">S25</ref>, Supporting Information). In addition, the directed deposited/coated AgNWs cover a large surface area to reduce adhesion, resulting in electrical failure at the connecting points with the rigid DAQ systems. In comparison, the semi-embedded P-SSA electrodes prepared by the simple-yet-effect LIG-assisted transfer printing provide long-term, high-fidelity monitoring of electrophysiological signals in complex environments (even during exercise and heavy sweating). The comparison of the resulting P-SSA electrodes with other epidermal electrodes fabricated with various methods and materials further highlights the advantages of high WVTR, sufficient yet robust adhesion force, low skin contact impedance, skin-like modulus, and facile hardware integration for long-term monitoring in daily life (Figure <ref type="figure">4g</ref>, and Table <ref type="table">S1</ref>, Supporting Information).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5.">Application of P-SSA Electrodes for EMG, EOG, and EEG Monitoring</head><p>Three P-SSA electrodes placed on the wrist flexor muscle (inner forearm) of the human subjects record EMG signals (Figure <ref type="figure">5a</ref>). Grasping elastic balls with increasing gripping strength from 10 to 20 and then to 40 kg leads to increased peak amplitude in the EMG signals, and the larger amplitude recorded by the P-SSA electrodes proves its higher sensitivity than commercial gel electrodes (Figure <ref type="figure">5b</ref>). The excellent EMG monitoring with the P-SSA electrodes under sweating conditions is highlighted in comparison with commercial gel electrodes (Figure <ref type="figure">5c</ref>,<ref type="figure">d</ref>). Upon sweating, the SNR of the commercial gel electrodes decreases significantly from 27.8 to 17.5 dB by 37.1%, along with significantly increased baseline noise from 2.1 to 4.8 &#956;V by 128.6%, demonstrating the deteriorating effect of sweat on the EMG monitoring (Figure <ref type="figure">5d</ref>,<ref type="figure">e</ref>). In contrast, the EMG signals measured by the P-SSA electrode with excellent water vapor permeability only exhibit a slight decrease in the SNR from 33.4 to 29.5 dB by 11.7%, together with a slight increase in the baseline noise from 1.6 to 2.3 &#956;V by 43.8%. As a result, the SSA electrode is more suitable for EMG monitoring in complex scenarios such as sweating, which is confirmed by a 48-h continuous wear experiment (Figure <ref type="figure">5f</ref>,<ref type="figure">g</ref>). Owing to the excellent conformality and breathability, the P-SSA electrodes exhibit a baseline noise of 1.7 &#956;V, which is lower than that of 2.1 &#956;V from the commercial Ag/AgCl gel electrode (Figure <ref type="figure">5h</ref>). Different from the commercial electrode with the baseline noise increased significantly from 2.1 to 4.5 &#956;V by 114.3% after 48 h of continuous wear (likely due to the dehydration of the gel), the SSA electrode only features a slight increase in the baseline noise from 1.7 to 2.3 &#956;V by 35.3%. The much smaller drift in the baseline noise (i.e., 33%) from the SSA electrode compared with its commercial gel electrode counterpart over sweating and long-term use highlights its salient performance.</p><p>Apart from the significant motion of the muscle fibers from the forearm, low-amplitude EMG signals generated by the finger flexion/extension can also be recorded by the epidermal P-SSA electrodes, which also exhibit higher amplitude than that of Ag/AgCl electrodes (Figure <ref type="figure">S26</ref>, Supporting Information). The enhanced EMG signal quality can contribute to high-precision human-computer interaction.</p><p>Placing the P-SSA electrodes near the eye records both vertical EOG and horizontal EOG signals (Figure <ref type="figure">S27a</ref>, Supporting Information). After setting the stable EOG signal when the subject is looking straight ahead as baseline waveform, the deviated waveform from the baseline during eye movements clearly identifies blink signals from the vertical EOG, <ref type="bibr">[37]</ref> periodic up/down and side-to-side eye motions (Figure <ref type="figure">S27b</ref>, Supporting Information).</p><p>Although EEG signals are of great significance for the diagnosis and therapy of brain diseases, high-quality recording of EEG signals is more challenging than ECG and EMG signals due to the significantly lower magnitude and the presence of the hair. <ref type="bibr">[38]</ref> In the proof-of-the-concept demonstration for the EEG monitoring, the test electrode is placed on the forehead (Fp1) with the ground/reference electrodes on the right/left mastoids according to the international 10/20 system (Figure <ref type="figure">S28a</ref>  Supporting Information). Compared to the power during sleeping (Figure <ref type="figure">S29a</ref>, Supporting Information), the EEG during eye opening over cyclic eye closing/opening has a higher signal amplitude (Figure <ref type="figure">S29b</ref>, Supporting Information). Compared with previously reported epidermal EEG and EOG electrodes, the EEG and EOG signals captured by the P-SSA electrodes feature higher power spectral density (PSD) of alpha wave (Table <ref type="table">S2</ref>, Supporting Information) and larger amplitude in the EOG signals (Table <ref type="table">S3</ref>, Supporting Information), respectively.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.6.">Epidermal P-SSA Electrode Arrays for Gesture Classification and Recognition</head><p>The large-scale patterning and manufacturing of the epidermal P-SSA electrodes can provide an intrinsically stretchable eight-channel epidermal bioelectrode system with eight pairs of electrodes applied to the forearm for gesture recognition (Figure <ref type="figure">6a</ref>,<ref type="figure">b</ref>). After direct connecting the AgNWs network-based terminal pads to the flexible printed circuit board (fPCB) without soldering, the acquired EMG data can be displayed on a custombuilt graphical user interface (GUI) in real time (Figure <ref type="figure">S30</ref>, Supporting Information). The EMG signals from eight hand gestures exhibit significant differences (Figure <ref type="figure">6c</ref>,<ref type="figure">d</ref>), which can be processed by a deep learning algorithm based on a Convolutional Neural Network (CNN) (Figure <ref type="figure">6e</ref>) for gesture classification and recognition. The CNN model consists of two residual neural network modules with integrated attention mechanisms connected in series, followed by two fully connected layers that output eight classification results. In the gathered 110 groups of data for each gesture, each data segment contains 8 channels with 5500 sampling points in each channel. With 80% of the data randomly selected as the training set and the remaining 20% as the test set for each gesture, the CNN model demonstrates a high overall recognition accuracy of 95.4% for the recognition of eight gestures (Figure <ref type="figure">6f</ref>), showing great potential for applications in human-machine interaction.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Conclusion</head><p>In summary, the direct patterning and complete transfer of the porous AgNWs network from the LIG onto thin, low-modulus, stretchable perforated substrates result in ultra-conformal and breathable epidermal electrodes. The resulting electrodes intimately conform to the skin with dynamically stable and low contact impedance even over heavy sweating, providing remarkable long-term electrophysiological sensing performances in complex environmental conditions with minimized discomfort and risk of inflammation. The highly efficiency, low-cost, and large-area method also allows facile fabrication of an eightchannel EMG system coupled with a deep learning algorithm for gesture recognition with high accuracy. The results from this study also provide design principles and fabrication methods for future epidermal electronics with long-term stability for high-fidelity health monitoring and high-precision human-robot collaborations.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.">Experimental Section</head><p>Materials: Styrene-block-poly (ethylene-ran-butylene)-block-polystyrene (SEBS, Mw-118000) was purchased from Sigma-Aldich. Silbione RT GEL 4317A/B was purchased from Elkem Silicones. The AgNWs dispersion in ethanol (10 mg/mL, average diameter of 90 nm, length of 60 &#956;m) was obtained from XFNANO Corporation. Toluene (99.5%) was purchased from General Reagent. Commercially available polyimide (PI) film was provided by DuPont (Kapton HN, with a thickness of 60 &#956;m). All other materials, solvents, and reagents were obtained from commercial sources and used without further purification.</p><p>Preparation of Patterned LIG: The fabrication of patterned LIG started with cleaning of a piece of PI sheet. Subsequently, porous graphene was patterned on PI using a CO 2 infrared laser with a wavelength of 10.6 &#956;m and beam spot size of &#8776;25 &#956;m (VLS3.50, Universal Laser System, Inc). In all experiments, the setting was fixed at 8% of the maximum power and 11% of the maximum scanning speed. The image density and PPI were set as 6 and 1000. All experiments were performed under ambient conditions.</p><p>Preparation of Porous Stretchable Substrates: First, a piece of release paper was attached to a 1 mm-thick glass plate using double-sided tape. After spin-coating (1000 rpm, 30 s) SEBS solution (15 wt.%, in toluene) on the release paper and after evaporating the toluene, Silbione mixed at a 1:1 ratio was spin-coated (1000 rpm, 30 s) and cured on a hot plate at 90 &#176;C for 10 min. Next, CO 2 laser scribing was employed to obtain micro-perforations over the entire substrate, with a perforation diameter of 0.16 mm and spacing of 0.64 mm. The laser scribing was performed using parameters set at 16% power and 15% speed.</p><p>Preparation of Ultra-Conformal P-SSA Epidermal Electrodes: The Ag-NWs dispersion with a precisely controlled amount was first dropped onto the LIG pattern using a pipette. Evaporation of ethanol allowed the AgNWs network to form on the LIG surface with the same patterned shape. Next, the adhesive side of the stretchable substrate on the release paper was applied to the top of AgNWs/LIG. Gent peeling transferred patterned AgNWs to the stretchable substrate to result in the ultra-conformal and breathable epidermal electrodes, which was followed by the removal of the release paper after applying the electrode to the skin.</p><p>Characterization: The SEM images were obtained by field emission scanning electron microscopy (Thermo Scientific Apreo 2C). The stressstrain curve was measured by the M230pro (YiGao) at a tensile speed of 30 mm min -1 . The 90-degree on-body peeling tests of the epidermal electrodes were also carried out with M230pro (YiGao) by adhering samples with an area of 15 &#215; 60 mm to ethanol-treated human skin at a tensile speed of 30 mm min -1 . The sheet resistance was measured using a four-probe sheet resistance meter (HPS58006, Helpass). The skincontact impedance was measured by using an electrochemical workstation (CHI660E, ChenHua). The water vapor transmission rate was measured based on the ASTM E96 standard. In brief, 10 mL of deionized water was first placed inside a 20 mL glass bottle, which was sealed with a 100 &#956;m thick sample and then placed in a drying cabinet at a temperature of 20 &#176;C and a relative humidity of 25% &#177; 5%. The mass of the glass bottle was measured every 12 h to calculate the water vapor transmission rate (based on the mass change).</p><p>Calculation of Transfer Yield: The AgNWs from the same surface area of LIG before (and after) transfer, represented by manually marked green For the dense AgNWs (5, 10, and 40 &#956;L cm -2 ) that cannot be counted manually, the number of AgNWs at a concentration of 1 &#956;L/cm 2 on the LIG surface counted from the unit area (10 283.120 &#177; 3303.771 per mm 2 ) was scaled with the concentration factor to estimate the number of dense AgNWs before transfer.</p><p>Electrophysiological Signal Recording: For all electrophysiological recordings, the epidermal electrodes were conformally attached to human skin, with metal wires connecting the AgNWs layer of the electrodes to a commercialized amplifier (PowerLab 4/26, ADInstruments). ECG signals were recorded with two working electrodes (diameter of 15 mm) placed on the volunteer's inner wrists and the reference electrode placed on the left foot (sampling rate of 1 kHz with a 1-50 Hz bandpass filter). The </p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>16163028, 0, Downloaded from https://advanced.onlinelibrary.wiley.com/doi/10.1002/adfm.202504481, Wiley Online Library on [10/04/2025]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_1"><p>&#169; 2025 The Author(s). Advanced Functional Materials published by Wiley-VCH GmbH 16163028, 0, Downloaded from https://advanced.onlinelibrary.wiley.com/doi/10.1002/adfm.202504481, Wiley Online Library on [10/04/2025]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_2"><p>Adv. Funct. Mater. 2025, 2504481 2504481 (10 of 13) &#169; 2025 The Author(s). Advanced Functional Materials published by Wiley-VCH GmbH 16163028, 0, Downloaded from https://advanced.onlinelibrary.wiley.com/doi/10.1002/adfm.202504481, Wiley Online Library on [10/04/2025]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License</p></note>