Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 5:00 PM ET until 8:00 PM ET on Friday, September 11 due to maintenance. We apologize for the inconvenience.


Title: Muons in air showers with IceCube: muon density at ground and high-energy muon multiplicity
Various measurements of muons in air showers using ground-based particle detector arrays have indicated a discrepancy between observed data and predictions from simulations. The IceCube Neutrino Observatory can offer unique insights into this issue. Its surface array, IceTop, measures the muon density at large lateral distances, while the deep in-ice detector provides information on high-energy muons. Recent analyses have determined the surface muon density and the high-energy (Eμ≳ 500 GeV) muon multiplicity in near-vertical air showers for primary energies ranging from 2.5 PeV to 100 PeV. In this contribution, we present the results and discuss their consistency with predictions from current hadronic interaction models.  more » « less
Award ID(s):
2209483
PAR ID:
10621550
Author(s) / Creator(s):
;
Corporate Creator(s):
Publisher / Repository:
Sissa Medialab
Date Published:
Page Range / eLocation ID:
035
Format(s):
Medium: X
Location:
Malargüe, Mendoza, Argentina
Sponsoring Org:
National Science Foundation
More Like this
  1. The IceCube Neutrino Observatory at the geographic South Pole, with its surface array IceTop, detects three different components of extensive air showers: the total signal at the surface, low energy muons on the periphery of the showers, and high energy muons in the deep In Ice array of IceCube. These measurements enable determination of the energy spectrum and composition of cosmic rays from PeV to EeV energies, the anisotropy in the distribution of cosmic ray arrival directions, the muon density of cosmic ray air showers, and the PeV gamma-ray flux. Furthermore, IceTop can be used as a veto for the neutrino measurements. The latest results from these IceTop analyses will be presented along with future plans. 
    more » « less
  2. IceCube is a cubic-kilometer Cherenkov detector in the deep ice at the geographic South Pole. The dominant event yield in the deep ice detector consists of penetrating atmospheric muons with energies above approximately 300 GeV, produced in cosmic ray air showers. In addition, the surface array, IceTop, measures the electromagnetic component and GeV muons of air showers. Hence, IceCube and IceTop yield unique opportunities to study cosmic rays with unprecedented statistics in great detail. We will present recent results of comic ray measurements from IceCube and IceTop. In this overview, we will highlight measurements of the energy spectrum of cosmic rays from 250 TeV up to the EeV range and their mass composition above 3 PeV. We will also report recent results from measurements of the muon content in air showers and discuss their consistency with predictions from current hadronic interaction models. 
    more » « less
  3. We present a measurement of the mean number of muons with energies larger than 500 GeV in near-vertical extensive air showers initiated by cosmic rays with primary energies between 2.5 and 100 PeV. The measurement is based on events detected in coincidence between the surface and in-ice detectors of the IceCube Neutrino Observatory. Air showers are recorded on the surface by IceTop, while a bundle of high-energy muons (TeV muons) from the shower can subsequently produce a tracklike event in the IceCube in-ice array. Results are obtained assuming the hadronic interaction models Sibyll 2.1, QGSJet-II.04, and EPOS-LHC. The measured number of TeV muons is found to be in agreement with predictions from air-shower simulations. The results have also been compared to a measurement of low-energy muons by IceTop, indicating an inconsistency between the predictions for low- and high-energy muons in simulations based on the EPOS-LHC model. 
    more » « less
  4. Capone, A.; De Vincenzi, M.; Morselli, A. (Ed.)
    The IceCube Neutrino Observatory located at the geographic South Pole is composed of two detectors. One is the in-ice optical array, which measures high-energy muons from air showers and charged particles produced by the interaction of high-energy neutrinos in the ice. The other is an array of ice-Cherenkov tanks at the surface, called IceTop, which is used both as veto for the in-ice neutrino measurements and for detecting cosmic-ray air showers. In the next decade, the IceCube-Gen2 extension will increase the surface coverage including surface radio antennas and scintillator panels on the footprint of an extended optical array in the ice. The combination of the current surface and in-ice detectors can be exploited for the study of cosmic rays and the search for PeV gamma rays. The in-ice detector measures the high-energy muonic component of air showers, whereas the signal in IceTop is dominated by the electromagnetic component. The relative size of the muonic and electromagnetic components is different for gamma-and hadron-induced air showers. Thus, the gamma-hadron separation of cosmic rays is attempted using machine learning techniques including deep learning. Here, different approaches are presented. Finally, the prospects for the detection of PeV photons with IceCube-Gen2 will be discussed. 
    more » « less
  5. We present a novel approach for assessing the muon content of air showers with large zenith angles on a combined analysis of their radio emission and particle footprint. We use the radiation energy reconstructed by the Auger engineering radio array (AERA) as an energy estimator and determine the muon number independently with the water-Cherenkov detector array of the Pierre Auger Observatory, deployed on a 1500 m grid. We focus our analysis on air showers with primary energy above 4 EeV to ensure full detection efficiency. Over approximately ten years of accumulated data, we identify a set of 40 high-quality events that are used in the analysis. The estimated muon contents in data are compatible with those for iron primaries as predicted by current-generation hadronic interaction models. This result can be interpreted as a deficit of muons in simulations as a lighter mass composition has been established from Xmax measurements. This muon deficit was already observed in previous analyses of the Auger Collaboration and is confirmed using hybrid events that include radio measurements for the first time. 
    more » « less