skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Illilouette Creek Basin Distributed Air Temperature and Relative Humidity 2015-2021
These files contain air temperature and relative humidity in Illilouette Creek Basin, within different post-fire vegetation patches including a wetland, shrub field, and forest. Onset's HOBO U23 Pro V2 temperature and relatively humidity sensors were attached to trees and protected using white plastic radiation shields. Temperatures measured may be impacted by temperature of the tree trunks. These time series can be used to compare air temperature and humidity at different heights above the ground, different canopy covers, and different sides of trees. These data can also be compared to temperature and relative humidity at nearby meteorological stations. Most of these sensors were temporarily removed in order to protect them from the 2017 Empire Fire, but sensor #315 remained in place and shows elevated temperatures on October 16, 2017 due to the fire. See Metadata file for details of sensor locations.  more » « less
Award ID(s):
2011346
PAR ID:
10625344
Author(s) / Creator(s):
Publisher / Repository:
Hydroshare
Date Published:
Format(s):
Medium: X
Location:
Yosemite National Park
Institution:
Desert Research Institute
Sponsoring Org:
National Science Foundation
More Like this
  1. The instrumented buoy on Lake Mendota is equipped with limnological and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. Data are collected every minute. Hourly and daily averages are derived from the high resolution (1 minute) data. Hourly and daily values may not be current with high resolution data as they are calculated at the end of the season. Meteorological sensors measure wind speed, wind direction, relative humidity, air temperature, and photosynthetically active radiation (PAR). Not all sensors are deployed each season. A list of sensors used since the first deployment in 2006 is provided as a downloadable CSV file. Number of sites: 1. Location lat/long: 43.0995, -89.4045 Notable events: 2017 - A boating mishap caused the loss of air temperature, relative humidity, and wind sensors between May 28 and July 11. The dissolved oxygen sensor had significant biofouling from algae and zebra mussels. 2019 - A YSI EXO2 sonde was added to the buoy and includes DO, chlorophyll, phycocyanin, specific conductance, pH, fDOM, and turbidity sensors. The chlorophyll and phycocyanin sensors replace Turner Cyclops 7 fluorometers that had been in use in prior years. Both sets of sensors output RFU, but have significant magnitude differences. The YSI pH, DO, and specific conductance sensors were cleaned and recalibrated every two weeks. 2020 - Cleaning and calibration of the YSI sensors occurred nearly every week. The dissolved CO2 sensor was not operating between July 2 and September 17. 2021 - Due to power and communications issues, the buoy was not operating August 22-31, and data is intermittent between November 8 and December 3. An effective method to keep the underwater PAR sensor mostly free of biofouling algae has been employed. 2022 - Buoy was not operating June 6-9 and July 2-5 due to power issues. Underwater PAR sensor unusable after October 1. 
    more » « less
  2. The data files in this data set contain climate information from sites on the North Slope of Alaska in or near the Kuparuk River basin. The data was collected for a hydrologic study of rivers in the North Slope region between 1985-present. Hydro-meteorological stations were established at various locations throughout the Kuparuk, but also in the Putuligayuk and Sagavanirktok watersheds. The variables collected at most stations were air temperature, humidity, wind speed and direction, soil temperature, snow temperature, precipitation, snow depth, and radiation. In the Imnavait Creek watershed (headwaters of the Kuparuk River), the Imnavait B site (IB) meteorological station operated from 1986 to present. This data package contains meteorological data from the Imnavait B site (IB) station and snow depth from the nearby station in the valley bottom (Imnavait Creek weir [IH]) collected from 2017 to 2023. Variables in this data package include air temperature, relative humidity, wind speed and direction, rainfall, and radiation at the Imnavait B site (IB) (2018-2023) and winter snow depth at Imnavait Weir (IH) (2017-2023). IMPORTANT NOTE: This dataset contains Imnavait B site (IB) meteorological data for 2018-2023. Updates and corrections to Imnavait B site (IB) (and others) were made in 2021 to the original datasets by the investigators, and all of the previously published data files (prior to 2008) should be replaced with the updated dataset (1985-2018) available at https://arcticdata.io/catalog/view/doi%3A10.18739%2FA2TQ5RF72. The following corrections were made to the datasets originally published in 2008 and 2010 (for data collected 1985-2008): 1) data from annual .csv files were merged into one .csv file (for each station) containing all years of data, 2) appended new data collected from 2008 to 2018 into the .csv file 3) standardized file headers, 4) standardized variable names, units, and sensor installation height above ground surface 5) reviewed all data for quality assurance and added qualifiers to erroneous data, 6) added a data qualifier to wind data during periods of extensive riming on wind sensors, 7) added a qualifier when air temperatures are below -39 degrees Celsius (C) (minimum reporting temperature of some air temperature sensors), and 8) removed duplicative data and fixed timestamp issues. See https://arcticdata.io/catalog/view/urn%3Auuid%3Ad5fa4cfa-b84b-4970-926a-8dd10b418e6d for additional climate data from other nearby stations in our studies. 
    more » « less
  3. Relative humidity has been measured within the Hubbard Brook Experimental Forest since 1956. Prior to 1981, relative humidity was measured at seven hygrothermographs within the forest, and minimum relative humidity at the time of maximum daily temperature was converted to vapor pressure. Digital data from the hygrothermograph charts are only available for three short periods prior to 1981: January 1966 to April 1966; June 1967 to Sept. 1967 and; May 1971 to April 1973. Beginning in 1981, a humidity sensor has operated as part of the automatic weather station at Headquarters. After installation of the digital sensor in 1981, mean daily air temperature and mean daily relative humidity were converted to vapor pressure. These data were gathered at the Hubbard Brook Experimental Forest in Woodstock, NH, which is operated and maintained by the USDA Forest Service, Northern Research Station. 
    more » « less
  4. Relative humidity has been measured within the Hubbard Brook Experimental Forest since 1956. Prior to 1981, relative humidity was measured at seven hygrothermographs within the forest, and minimum relative humidity at the time of maximum daily temperature was converted to vapor pressure. Digital data from the hygrothermograph charts are only available for three short periods prior to 1981: January 1966 to April 1966; June 1967 to Sept. 1967 and; May 1971 to April 1973. Beginning in 1981, a humidity sensor has operated as part of the automatic weather station at Headquarters. After installation of the digital sensor in 1981, mean daily air temperature and mean daily relative humidity were converted to vapor pressure. These data were gathered at the Hubbard Brook Experimental Forest in Woodstock, NH, which is operated and maintained by the USDA Forest Service, Northern Research Station. 
    more » « less
  5. Formaldehyde is a known human carcinogen and an important indoor and outdoor air pollutant. However, current strategies for formaldehyde measurement, such as chromatographic and optical techniques, are expensive and labor intensive. Low-cost gas sensors have been emerging to provide effective measurement of air pollutants. In this study, we evaluated eight low-cost electrochemical formaldehyde sensors (SFA30, Sensirion®, Staefa, Switzerland) in the laboratory with a broadband cavity-enhanced absorption spectroscopy as the reference instrument. As a group, the sensors exhibited good linearity of response (R2 > 0.95), low limit of detection (11.3 ± 2.07 ppb), good accuracy (3.96 ± 0.33 ppb and 6.2 ± 0.3% N), acceptable repeatability (3.46% averaged coefficient of variation), reasonably fast response (131–439 s) and moderate inter-sensor variability (0.551 intraclass correlation coefficient) over the formaldehyde concentration range of 0–76 ppb. We also systematically investigated the effects of temperature and relative humidity on sensor response, and the results showed that formaldehyde concentration was the most important contributor to sensor response, followed by temperature, and relative humidity. The results suggest the feasibility of using this low-cost electrochemical sensor to measure formaldehyde concentrations at relevant concentration ranges in indoor and outdoor environments. 
    more » « less