BackgroundLow back pain (LBP) is a significant public health problem that can result in physical disability and financial burden for the individual and society. Physical therapy is effective for managing LBP and includes evaluation of posture and movement, interventions directed at modifying posture and movement, and prescription of exercises. However, physical therapists have limited tools for objective evaluation of low back posture and movement and monitoring of exercises, and this evaluation is limited to the time frame of a clinical encounter. There is a need for a valid tool that can be used to evaluate low back posture and movement and monitor exercises outside the clinic. To address this need, a fabric-based, wearable sensor, Motion Tape (MT), was developed and adapted for a low back use case. MT is a low-profile, disposable, self-adhesive, skin-strain sensor developed by spray coating piezoresistive graphene nanocomposites directly onto commercial kinesiology tape. ObjectiveThe objectives of this study were to (1) validate MT for measuring low back posture and movement and (2) assess the acceptability of MT for users. MethodsA total of 10 participants without LBP were tested. A 3D optical motion capture system was used as a reference standard to measure low back kinematics. Retroreflective markers and a matrix of MTs were placed on the low back to measure kinematics (motion capture) and strain (MT) simultaneously during low back movements in the sagittal, frontal, and axial planes. Cross-correlation coefficients were calculated to evaluate the concurrent validity of MT strain in reference motion capture kinematics during each movement. The acceptability of MT was assessed using semistructured interviews conducted with each participant after laboratory testing. Interview data were analyzed using rapid qualitative analysis to identify themes and subthemes of user acceptability. ResultsVisual inspection of concurrent MT strain and kinematics of the low back indicated that MT can distinguish between different movement directions. Cross-correlation coefficients between MT strain and motion capture kinematics ranged from –0.915 to 0.983, and the strength of the correlations varied across MT placements and low back movement directions. Regarding user acceptability, participants expressed enthusiasm toward MT and believed that it would be helpful for remote interventions for LBP but provided suggestions for improvement. ConclusionsMT was able to distinguish between different low back movements, and most MTs demonstrated moderate to high correlation with motion capture kinematics. This preliminary laboratory validation of MT provides a basis for future device improvements, which will also involve testing in a free-living environment. Overall, users found MT acceptable for use in physical therapy for managing LBP.
more »
« less
This content will become publicly available on June 17, 2026
Carbon Nanotube Elastic Fabric Motion Tape Sensors for Low Back Movement Characterization
Monitoring posture and movement accurately and efficiently is essential for both physical therapy and athletic training evaluation and interventions. Motion Tape (MT), a self-adhesive wearable skin-strain sensor made of piezoresistive graphene nanosheets (GNS), has demonstrated promise in capturing low back posture and movements. However, to address some of its limitations, this work explores alternative materials by replacing GNS with multi-walled carbon nanotubes (MWCNT). This study aimed to characterize the electromechanical properties of MWCNT-based MT. Cyclic load tests for different peak tensile strains ranging from 1% to 10% were performed on MWCNT-MT made with an aqueous ink of 2% MWCNT. Additional tests to examine load rate sensitivity and fatigue were also conducted. After characterizing the properties of MWCNT-MT, a human subject study with 10 participants was designed to test its ability to capture different postures and movements. Sets of six sensors were made from each material (GNS and MWCNT) and applied in pairs at three levels along each side of the lumbar spine. To record movement of the lower back, all participants performed forward flexion, left and right bending, and left and right rotation movements. The results showed that MWCNT-MT exceeded GNS-MT with respect to consistency of signal stability even when strain limits were surpassed. In addition, both types of MT could assess lower back movements.
more »
« less
- Award ID(s):
- 2205093
- PAR ID:
- 10631166
- Publisher / Repository:
- MDPI
- Date Published:
- Journal Name:
- Sensors
- Volume:
- 25
- Issue:
- 12
- ISSN:
- 1424-8220
- Page Range / eLocation ID:
- 3768
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Background: Motion Tape (MT) is a low-profile, disposable, self-adhesive wearable sensor that measures skin strain. Preliminary studies have validated MT for measuring lower back movement. However, further analysis is needed to determine if MT can be used to measure lower back muscle engagement. The purpose of this study was to measure differences in MT strain between conditions in which the lower back muscles were relaxed versus maximally activated. Methods: Ten participants without low back pain were tested. A matrix of six MTs was placed on the lower back, and strain data were captured under a series of conditions. The first condition was a baseline trial, in which participants lay prone and the muscles of the lower back were relaxed. The subsequent trials were maximum voluntary isometric contractions (MVICs), in which participants did not move, but resisted the examiner force in extension or rotational directions to maximally engage their lower back muscles. The mean MT strain was calculated for each condition. A repeated measures ANOVA was conducted to analyze the effects of conditions (baseline, extension, right rotation, and left rotation) and MT position (1–6) on the MT strain. Post hoc analyses were conducted for significant effects from the overall analysis. Results: The results of the ANOVA revealed a significant main effect of condition (p < 0.001) and a significant interaction effect of sensor and condition (p = 0.01). There were significant differences in MT strain between the baseline condition and the extension and rotation MVIC conditions, respectively, for sensors 4, 5, and 6 (p = 0.01–0.04). The largest differences in MT strain were observed between baseline and rotation conditions for sensors 4, 5, and 6. Conclusions: MT can capture maximal lower back muscle engagement while the trunk remains in a stationary position. Lower sensors are better able to capture muscle engagement than upper sensors. Furthermore, MT captured muscle engagement during rotation conditions better than during extension.more » « less
-
Reaching movements performed from a crouched body posture require a shift of body weight from both arms to one arm. This situation has remained unexamined despite the analogous load requirements during step initiation and the many studies of reaching from a seated or standing posture. To determine whether the body weight shift involves anticipatory or exclusively reactive control, we obtained force plate records, hand kinematics, and arm muscle activity from 11 healthy right-handed participants. They performed reaching movements with their left and right arm in two speed contexts, “comfortable” and “as fast as possible,” and two postural contexts, a less stable knees-together posture and a more stable knees-apart posture. Weight-shifts involved anticipatory postural actions (APAs) by the reaching and stance arms that were opposing in the vertical axis and aligned in the side-to-side axis similar to APAs by the legs for step initiation. Weight-shift APAs were correlated in time and magnitude, present in both speed contexts, more vigorous with the knees placed together, and similar when reaching with the dominant and nondominant arm. The initial weight-shift was preceded by bursts of muscle activity in the shoulder and elbow extensors (posterior deltoid and triceps lateral) of the reach arm and shoulder flexor (pectoralis major) of the stance arm, which indicates their causal role; leg muscles may have indirectly contributed but were not recorded. The strong functional similarity of weight-shift APAs during crouched reaching to human stepping and cat reaching suggests that they are a core feature of posture-movement coordination. NEW & NOTEWORTHY This work demonstrates that reaching from a crouched posture is preceded by bimanual anticipatory postural adjustments (APAs) that shift the body weight to the stance limb. Weight-shift APAs are more robust in an unstable body posture (knees together) and involve the shoulder and elbow extensors of the reach arm and shoulder flexor of the stance arm. This pattern mirrors the forelimb coordination of cats reaching and humans initiating a step.more » « less
-
Abstract The extent to which hand dominance may influence how each agent contributes to inter-personal coordination remains unknown. In the present study, right-handed human participants performed object balancing tasks either in dyadic conditions with each agent using one hand (left or right), or in bimanual conditions where each agent performed the task individually with both hands. We found that object load was shared between two hands more asymmetrically in dyadic than single-agent conditions. However, hand dominance did not influence how two hands shared the object load. In contrast, hand dominance was a major factor in modulating hand vertical movement speed. Furthermore, the magnitude of internal force produced by two hands against each other correlated with the synchrony between the two hands’ movement in dyads. This finding supports the important role of internal force in haptic communication. Importantly, both internal force and movement synchrony were affected by hand dominance of the paired participants. Overall, these results demonstrate, for the first time, that pairing of one dominant and one non-dominant hand may promote asymmetrical roles within a dyad during joint physical interactions. This appears to enable the agent using the dominant hand to actively maintain effective haptic communication and task performance.more » « less
-
Abstract This study investigates the development of thermoplastic polyurethane (TPU) filaments incorporating multi‐walled carbon nanotubes (MWCNT) to enhance strain‐sensing capabilities. Various MWCNT reinforcement ratios are used to produce customized feedstock for fused filament fabrication (FFF) 3D printing. Mechanical properties and the piezoresistive response of samples printed with these multifunctional filaments are concurrently evaluated. Surface morphology and microstructural observations reveal that higher MWCNT weight percentages increase filament surface roughness and rigidity. The microstructural modifications directly influence the tensile strength and strain energy of the printed samples. The study identifies an apparent percolation threshold within the 10–12 wt.% MWCNT range, indicating the formation of a conductive network. At this threshold, higher gauge factors are achieved at lower strains. A newly introduced Electro‐Mechanical Sensitivity Ratio (ESR) parameter enables the classification of composite behaviors into two distinct zones, offering the ability to tailor self‐sensing structures with on‐demand properties. Finally, flexible structures with proven application in soft robotics and shape morphing are fabricated and tested at different loading conditions to demonstrate the potential applicability of the custom filaments produced. The results highlight a pronounced piezoresistive response and superior load‐bearing performance in the examined structures.more » « less
An official website of the United States government