Title: Water quality data for Green Lakes Valley, 2000 - ongoing.
This dataset contains water quality measurements made on Green Lakes 1, 2, 3, 4, 5, and Lake Albion. Green Lake 4 was initially sampled in 2000 and is ongoing. Ongoing sampling of Green Lakes 1 was started in 2014 and ongoing sampling of Lake Albion was started in 2016. Water samples were collected for analysis of chlorophyll a and nutrient analysis (which is available in glvwatsolu.dm.data) and field measurements for pH, temperature, specific conductivity, dissolved oxygen (DO), % saturation, secchi depth, PAR. Secchi depth is recorded at the 0m row however it is a measurement of depth and so the units are meters. Most samples were collected between 0800 and 1200 MST. The first sampling date each summer occurs shortly after the ice had melted. Data are collected from an inflatable raft at the point of deepest depth or from the lake inlet and outlet when surface flow is present. The majority of chlorophyll-a the measurements were taken at the surface (0m), the metalimnion (3m), and the hypolimnion nine (usually 8-11m). However, additional measurements were taken for side projects of the long-term dataset during several of the years and are included in this dataset. Water samples from the metalimnion or hypolimnion were collected using a Van Dorne sampler, and surface samples were collected as grab samples from the water column surface, the inlet and outlet. Field measurements were conducted using a YSI either DO or multiple probe meter (2014-2017, YSI MPS 556)(2018-ongoing, YSI ProPlus) and a Li-Cor meter with a quantum sensor. Chlorophyll-a was extracted from filtered samples and absorbance was measured before and after acidification to quantify chlorophyll a concentration.  more » « less
Award ID(s):
2224439
PAR ID:
10632778
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Environmental Data Initiative
Date Published:
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. This dataset includes chlorophyll-a concentrations, periphyton biomass estimates, water quality measurements, and qualitative observations from a large-scale mesocosm experiment conducted in the Green Lakes Watershed, Colorado. The experiment was designed to test how earlier lake ice-off and increased dissolved organic material (DOM), associated with terrestrial plant encroachment in alpine watersheds, interactively influence aquatic food webs. In fall 2019, twenty 2600L “megacosms” were established at Sandy Corner (3300 m ASL; 40.042289, -105.584006), left to fill with snowmelt, and maintained throughout the 2020 open water season. The experiment followed a 2 × 2 randomized block design manipulating ice-off timing (via black vs. beige tank coloration) and DOM inputs (presence/absence of willow leaf packs), with five replicates per treatment. All tanks were seeded with sediments and zooplankton from both alpine and montane lakes (Green Lake 1 and Green Lake 4), and instrumented with thermistors recording surface and hypolimnion temperature every two hours year-round. Periphyton growth was monitored using clay tiles, sampled across five time points. Chlorophyll-a concentrations were extracted from filtered water samples and analyzed spectrophotometrically. Periphyton biomass was estimated via ash-free dry mass (AFDM) determinations, based on the mass lost on combustion of material scraped from tiles. Water quality was measured 1–2 times weekly using a YSI ProPlus multiprobe and Li-Cor quantum sensor, and snow/ice cover was qualitatively assessed monthly during winter. 
    more » « less
  2. Parameters characterizing the major ions of the eleven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, Trout, bog lakes 27-02 [Crystal Bog], and 12-15 [Trout Bog], Mendota, Monona, Wingra and Fish) are measured at one station in the deepest part of each lake at the top and bottom of the epilimnion, mid-thermocline, and top, middle, and bottom of the hypolimnion. These parameters include chloride, sulfate, calcium, magnesium, sodium, potassium, iron, manganese, and specific conductance (northern lakes only). Lake Wingra has always been just a surface sample, but in the winter we have, at times, taken chloride samples from top to bottom to have a better understanding of road salt effects. Samples for conductivity are collected four times per year in the seven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes, and unnamed lakes 27-02 [Crystal Bog], and 12-15 [Trout Bog] in the Trout Lake area at the deepest part of the lake, sampling at the surface, mid water column, and the bottom. The sampling dates include February under ice, spring mixis, August stratified, and fall mixis. Conductivity is measured using a YSI Model 32 conductivity meter with YSI 3403 conductivity cell, reported as uS/cm at 25°C. 1981-1988: a Sybron Barnstead conductivity bridge was used. 1981-1986: conductivity was measured monthly. Sampling Frequency: quarterly (winter, spring and fall mixes, and summer stratified periods) Number of sites: 11 
    more » « less
  3. Discrete depth profiles of water temperature, dissolved oxygen, oxidation-reduction potential, conductivity, specific conductance, and pH were collected with various handheld YSI water quality probes and discrete depth profiles of photosynthetically active radiation (PAR) were collected with a LI-COR underwater light meter from 2013 to 2023 in five drinking water reservoirs in southwestern Virginia, USA. These reservoirs are: Beaverdam Reservoir (Vinton, Virginia), Carvins Cove Reservoir (Roanoke, Virginia), Falling Creek Reservoir (Vinton, Virginia), Gatewood Reservoir (Pulaski, Virginia), and Spring Hollow Reservoir (Salem, Virginia). Beaverdam, Carvins Cove, Falling Creek, and Spring Hollow Reservoirs are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia, and Gatewood Reservoir is a drinking water source for the Town of Pulaski, Virginia. All YSI and PAR depth profiles were collected on approximately 1-meter intervals. The data package consists of two datasets: 1) Secchi depth data; and 2) YSI and PAR profiles. The Secchi depths and YSI and PAR depth profiles were measured at the deepest site of each reservoir adjacent to the dam and other in-reservoir transects. YSI measurements were also collected at a gauged weir on the primary inflow tributary, other inflows and outflows at Falling Creek, inflows and outflows at Beaverdam, and inflows at Carvins Cove. In 2021, YSI profiles were also collected from a littoral site in Beaverdam. Data were collected approximately fortnightly in the spring months (March - May), weekly in the summer and early autumn (June - September), and monthly in the late autumn and winter (October - February) in Falling Creek and Beaverdam Reservoirs; data coverage in the other three reservoirs varies among years. Note there are some YSI profiles and Secchi observations that were measured at night during overnight sampling. All of these observations have the correct time associated with them. There was a major revision of this dataset from version 11, which includes correcting times of observations, including negative ORP values, and adding observations from an outflow at Falling Creek Reservoir. 
    more » « less
  4. Discrete depth profiles of temperature, dissolved oxygen, oxidation-reduction potential, conductivity, specific conductance, and pH were collected with various handheld YSI water quality probes and discrete depth profiles of photosynthetic active radiation (PAR) were collected with a LI-COR underwater light meter from 2013 to 2022 in five drinking water reservoirs in southwestern Virginia, USA. Secchi disk depth data complement the PAR data to estimate water transparency. All YSI and PAR depth profiles were collected on approximately 1-meter intervals. These reservoirs are: Beaverdam Reservoir (Vinton, Virginia), Carvins Cove Reservoir (Roanoke, Virginia), Falling Creek Reservoir (Vinton, Virginia), Gatewood Reservoir (Pulaski, Virginia), and Spring Hollow Reservoir (Salem, Virginia). Beaverdam, Carvins Cove, Falling Creek, and Spring Hollow Reservoirs are owned and operated by the Western Virginia Water Authority as primary or secondary drinking water sources for Roanoke, Virginia, and Gatewood Reservoir is a drinking water source for the Town of Pulaski, Virginia. The data package consists of two datasets: 1) YSI and PAR profiles; and 2) Secchi depth data. The YSI and PAR depth profiles and Secchi depths were measured at the deepest site of each reservoir adjacent to the dam and other in-reservoir transects. YSI measurements were also collected at a gauged weir on the primary inflow tributary at Falling Creek, other inflows and outflows at Falling Creek, inflows and outflows at Beaverdam, and inflows at Carvins Cove. In 2021, YSI profiles were also collected from a littoral site in Beaverdam. Data were collected approximately fortnightly in the spring months (March - May), weekly in the summer and early autumn (June - September), and monthly in the late autumn and winter (October - February) in Falling Creek and Beaverdam Reservoirs; data coverage in the other three reservoirs varies among years. 
    more » « less
  5. The Lake Mendota Microbial Observatory collects routine water clarity measurements alongside their microbial samples. This dataset includes measurements of water clarity collected at the central Deep Hole, collocated with a weather buoy (43°05'58.2"N 89°24'16.2"W). All measurements were collected with handheld Secchi discs. When multiple personnel performed the Secchi disc measurements, the average and standard deviation are reported. To take the Secchi depth, sunglasses are removed and the disc is lowered on the shaded side of the boat. The Secchi depth is the average between where the Secchi disc disappears while lowering it and where it reappears while raising it. Routine microbial observatory sampling continues into the present. 
    more » « less