Title: Understanding Patterns of Neonatal Brachial Plexus Palsy Using a 3D Finite Element Model
Neonatal brachial plexus palsy is a birth process-related injury that affects 1–2/1000 infants, with about 10% of those having a permanent deficit that can affect the muscle strength, range of motion, and sensation of the upper extremity. While computational models make the most sense for investigation of injury mechanisms in the vulnerable infant population, the models remain very simplified – incorporating only a single indicator nerve that mimics the response of the C5 nerve root rather than taking into consideration the complex, 3D anatomy of the plexus. Two existing finite element models of the adult brachial plexus have been published – but neither attempts to model the complex anatomy of the plexus through the divisions, cords, and terminal nerves. This project involved the development of an anatomically appropriate 3D model of the infant brachial plexus. This is the first published finite element model of the full, complex anatomy of the brachial plexus and the first that includes an appropriate anatomy for an infant. The model was then used to better understand the pattern and progression of brachial plexus injury that has been observed clinically in neonates. The model was able to predict a stress distribution that aligns with the C5 nerve root being the location of initial injury. It also demonstrated how the stress in remaining, intact nerve roots will increase when rupture or avulsion of C5 and then C6 occurs – which matches the progression of the injury from the upper plexus (an Erb’s Palsy) to the middle and lower plexus.  more » « less
Award ID(s):
2028474
PAR ID:
10635061
Author(s) / Creator(s):
;
Editor(s):
Taiar, Redha
Publisher / Repository:
IntechOpen
Date Published:
ISBN:
978-1-83635-039-2
Subject(s) / Keyword(s):
Brachial plexus neonatal palsy finite element model infant injury
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Chaudhary, Priti (Ed.)
    The brachial plexus is a set of nerves that innervate the upper extremity and may become injured during the birthing process through an injury known as Neonatal Brachial Plexus Palsy. Studying the mechanisms of these injuries on infant cadavers is challenging due to the justifiable sensitivity surrounding testing. Thus, these specimens are generally unavailable to be used to investigate variations in brachial plexus injury mechanisms. Finite Element Models are an alternative way to investigate the response of the neonatal brachial plexus to loading. Finite Element Models allow a virtual representation of the neonatal brachial plexus to be developed and analyzed with dimensions and mechanical properties determined from experimental studies. Using ABAQUS software, a two-dimensional brachial plexus model was created to analyze how stresses and strains develop within the brachial plexus. The main objectives of this study were (1) to develop a model of the brachial plexus and validate it against previous literature, and (2) to analyze the effect of stress on the nerve roots based on variations in the angles between the nerve roots and the spinal cord. The predicted stress for C5 and C6 was calculated as 0.246 MPa and 0.250 MPa, respectively. C5 and C6 nerve roots experience the highest stress and the largest displacement in comparison to the lower nerve roots, which correlates with clinical patterns of injury. Even small (+/- 3 and 6 degrees) variations in nerve root angle significantly impacted the stress at the proximal nerve root. This model is the first step towards developing a complete three-dimensional model of the neonatal brachial plexus to provide the opportunity to more accurately assess the effect of the birth process on the stretch within the brachial plexus and the impact of biological variations in structure and properties on the risk of Neonatal Brachial Plexus Palsy. 
    more » « less
  2. Despite improvements in obstetric care, neonatal brachial plexus palsy continues to significantly impact infants’ lives worldwide, with an incidence of 1 to 4 per 1000 live births. While a majority of affected infants recover spontaneously by three months, 20-30% suffer permanent functional deficits that significantly impair their quality of life. Anatomical complexity of the brachial plexus results in varying degrees of injury and pathological changes at multiple levels within the plexus. Current clinical diagnosis relies on electrodiagnostic techniques such as nerve conduction (i.e., motor and sensory) and electromyography studies. These techniques not only aid clinicians to differentiate between axonal and demyelinating lesions, evident by changes in signal shape and conduction, but also provide prognostic information in cases of brachial plexus injuries. The presented study offers a comprehensive review of existing literature on electrodiagnostic techniques employed for assessing neonatal brachial plexus injuries. 
    more » « less
  3. Neonatal brachial plexus palsy is a devastating complication occurring during complicated birthing scenarios including shoulder dystocia. To understand the effects of maneuvers that reduce forces required for delivery following shoulder dystocia, tools that simulate the birthing scenarios are needed. Incorporation of brachial plexus responses is further required to help understand the mechanism of neonatal brachial plexus palsy and devise strategies that can help prevent them. Given the inability to measure forces and tissue strains during actual birthing process, computer and physical models serve as optimal tools with its known limitations. This mini-review highlights and summaries available computational and physical models that can help understand brachial plexus injury mechanisms in neonates following complicated delivery including shoulder dystocia. 
    more » « less
  4. null (Ed.)
    Abstract Brachial plexus birth injury has a reported incidence of 1 to 4 per 1000 live births. During complicated deliveries, neonatal, maternal, and other birth-related factors can cause over-stretching or avulsion of the neonatal brachial plexus leading to injury. Understanding biomechanical responses of the neonate brachial plexus when subjected to stretch can offer insight into the injury outcomes while guiding the development of preventative maneuvers that can help reduce the occurrence of neonatal brachial plexus injuries. This review article aims to offer a comprehensive overview of existing literature reporting biomechanical responses of the brachial plexus, in both adults and neonates, when subjected to stretch. Despite the discrepancies in the reported biomechanical properties of the brachial plexus, the studies confirm the loading rate and loading direction dependency of the brachial plexus tissue. Future studies, possibly in vivo, that utilize clinically-relevant neonatal large animal models can provide translational failure values of the biomechanical parameters for the neonatal brachial plexus when subjected to stretch. 
    more » « less
  5. Abstract This study investigated the biomechanical responses of neonatal piglet brachial plexus (BP) segments—root/trunk, chord, and nerve at two different rates, 0.01 mm/second (quasistatic) and 10 mm/second (dynamic)—and compared their response to another peripheral nerve (tibial). Comparisons of mechanical responses at two different rates reported a significantly higher maximum load, maximum stress, and Young's modulus (E) values when subjected to dynamic rate. Among various BP segments, maximum stress was significantly higher in the nerve segments, followed by chord and then the root/trunk segments except no differences between chord and root/trunk segments at quasistatic rate. E values exhibited similar behavior except no differences between the chord and root/trunk segments at both rates and no differences between chord and nerve segments at quasistatic rate. No differences were observed in the strain values. When compared with the tibial nerve, only mechanical properties of BP nerves were similar to the tibial nerve. Mechanical stresses and E values reported in BP root/trunk and chord segments were significantly lower than tibial nerve at both rates. When comparing the failure pattern, at quasistatic rate, necking was observed at maximum load, before a complete rupture occurred. At dynamic rate, partial rupture at maximum load, followed by a full rupture, was observed. Occurrence of the rate-dependent failure phenomenon was highest in the root/trunk segments followed by chord and nerve segments. Differences in the maximum stress, E values, and failure pattern of BP segments confirm variability in their anatomical structure and warrant future histological studies to better understand their stretch responses. 
    more » « less