<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Comparing Advanced Bipolar Membranes for High-Current Electrodialysis and Membrane Electrolysis</title></titleStmt>
			<publicationStmt>
				<publisher>ACS</publisher>
				<date>02/14/2025</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10637424</idno>
					<idno type="doi">10.1021/acsenergylett.4c03538</idno>
					<title level='j'>ACS Energy Letters</title>
<idno>2380-8195</idno>
<biblScope unit="volume">10</biblScope>
<biblScope unit="issue">2</biblScope>					

					<author>Olivia T Vulpin</author><author>James B Mitchell</author><author>Lihaokun Chen</author><author>Jeonghoon Lim</author><author>Sayantan Sasmal</author><author>Nathan G Price</author><author>Sam R Jarvis</author><author>Shannon W Boettcher</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Advanced bipolar membranes (BPMs) with low water-dissociation overpotential (η wd ) may enable new electrochemical technologies for electrolysis, fuel cells, acid-base synthesis, brine remediation, lithium-battery recycling, and cement production. However, these advanced BPMs have only been demonstrated in BPM water electrolysis (BPMWE) configurations where the BPM is under static compression by the porous-transport layers. It is important to study these BPMs in applications like electrodialysis where large degrees of static compression are not possible. We present a BPM electrodialysis (BPMED) platform to measure water-dissociation overpotential (η wd ) and compare BPMWE and BPMED systems. We show advanced BPMs with half the η wd compared to commercial BPMs for BPMED while maintaining ∼90% current efficiency from 0.05-0.5 A cm -2 . The BPMED η wd values are, however, about 0.2 V higher at 0.5 A cm -2 than those for BPMWE. Regardless, these results show that BPMs developed and optimized in BPMWE applications are well-suited for next-generation high-current-density BPMED technologies.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><p>B ipolar membranes (BPMs) are composed of a polymeric anion-exchange layer (AEL) and cationexchange layer (CEL) sandwiched together around a catalytic layer that speeds water dissociation (Figure <ref type="figure">1a</ref>). These polymers are ionomers composed typically of a hydrophobic backbone functionalized with stationary charged groups, such as sulfonic acid groups for the CEL and quaternary ammonium groups for the AEL. <ref type="bibr">1</ref> Ion-exchange layers conduct ions with opposite sign (counterions) to those of the charged groups bound to the backbone and exclude ions of the same sign (co-ions). With these differently charged layers, the BPM is able to maintain large pH gradients via water dissociation at the junction of the CEL and AEL, making them useful for a broad range of applications, such as electrolyzers, fuel cells, desalination, acid-base production, brine remediation, and lithium recovery, among others. <ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref><ref type="bibr">[6]</ref> Broadly, these technological applications fall into two categories-those where electrolytes freely flow on either side of the BPM, such as in electrodialysis (Figure <ref type="figure">1c</ref>) and those where the BPM is part of a membrane-electrode assembly, such as in an electrolyzer or fuel cell, and compressed under high static pressure via a rigid porous-transport layer and where the electrolyte flows along the electrodes, not interfacing directly with the BPM (Figure <ref type="figure">1b</ref>).</p><p>Membrane-electrode assemblies have become a primary test platform for understanding the mechanisms governing the function of BPMs, and consequently the platform that has seen the most advancement in BPM technology. BPM-containing membrane-electrode assemblies provide a system where the only mobile ions are H + and OH -, unlike BPM electrodialysis systems where a range of mobile ions are present depending on the supporting electrolytes, complicating models and electrochemical analysis. Furthermore, membrane-electrode assemblies hold the BPM under spatially even, static compression, which has been shown to impact performance of the ionomer layers making up the BPM, while the freely flowing electrodialysis applications for BPM are generally unable to provide consistent static pressure to the BPM. <ref type="bibr">[7]</ref><ref type="bibr">[8]</ref><ref type="bibr">[9]</ref> The ionic resistance of the BPM can be broken into two parts, the resistance of the membrane layers (CEL and AEL) and the water dissociation (WD, H 2 O &#8594; H + + OH -) resistance, which can be equivalently cast as the WD overpotential (&#951; wd ) as a function of current. To address membrane layer resistance, diverse polymer structures have been proposed and synthesized to reduce counterion transport resistance through the membrane, while assuring that adequate co-ion selectivity of the membrane is maintained for a given application. <ref type="bibr">10,</ref><ref type="bibr">11</ref> Similarly, researchers have focused on understanding the mechanisms that underly the measured &#951; wd within the BPM to inform WD catalyst designs. <ref type="bibr">12,</ref><ref type="bibr">13</ref> Historically, &#951; wd was the largest source of voltage inefficiency in the BPM, but this is now changing due to the introduction of advanced WD catalyst designs that dramatically speed the WD reaction within the BPM. <ref type="bibr">[14]</ref><ref type="bibr">[15]</ref><ref type="bibr">[16]</ref><ref type="bibr">[17]</ref> The precise molecular mechanisms of WD within these BPM junctions remain unsettled. Initial theories around "WD catalysis" arose from the hypothesis that weakly basic tertiary amino groups on the AEL near the BPM junction could accept and donate protons as an intermediate step in the WD reaction. <ref type="bibr">14</ref> Recently, the BPM water electrolysis (BPMWE) architecture, where the only mobile ions are H + and OH -, has been used to understand the WD reaction and to test and improve new WD catalysts, practically leading to &gt;20&#215; reduction in &#951; wd . <ref type="bibr">18</ref> The acid-base properties of metal-oxide nanoparticles in the BPM junction are thought to be important for catalyst bilayers, as evidenced by the connection between the pH of zero charge on the metal-oxide and the local pH near the AEL, or CEL, in the BPM. <ref type="bibr">12</ref> The impact of interfacial electric field is also important; adding noncatalytic electronically conductive carbon particles at the BPM junction increases the rate of WD perhaps by focusing the electric field at the interfaces where WD occurs. <ref type="bibr">10,</ref><ref type="bibr">[19]</ref><ref type="bibr">[20]</ref><ref type="bibr">[21]</ref> In the above cases, the introduced WD catalysts are typically in the form of metaloxide nanoparticles and are applied to the junction between the two layers of the BPM without supporting ionomer or other polymer adhesive, likely in part leading to the high performance. <ref type="bibr">10,</ref><ref type="bibr">12,</ref><ref type="bibr">22</ref> One limitation of much of the work on advanced catalyzed BPM is that they have been studied in the BPMWE platform where the BPM is under static compression in the membraneelectrode assembly (MEA) and fed pure water. As compared to a BPM in applications like electrodialysis, where the BPM is exposed to a wide range of free-flowing electrolytes, leading to possible ion contamination and low static pressure holding the BPM together. Here we study how advanced BPMs, with excellent BPMWE performance in MEAs, operate in a BPM electrodialysis (BPMED) stack.</p><p>BPMED is a technology that produces acid and base from brine (salt) solution (Figure <ref type="figure">1c</ref>). Historically, the design of BPMED systems have emphasized the production of highconcentration and high-purity solutions, with little focus on the energy efficiency. <ref type="bibr">[23]</ref><ref type="bibr">[24]</ref><ref type="bibr">[25]</ref> Thus, BPMED systems have generally used higher-resistance membranes that have good selectivity and can withstand high-concentration solutions without significant co-ion leakage. However, this means that these systems have low energy efficiency, especially when driven at higher currents, in exchange for high current efficiency. Further, the BPMs used in BPMED systems have not seen dramatic development since their implementation at the industrial level in the 1960s. <ref type="bibr">25,</ref><ref type="bibr">26</ref> BPMED systems can be configured with a wide range of electrolyte and membrane orientations, expanding their uses to applications including CO 2 capture, water purification, lithium and other metals separation and recovery, and even cementclinker production. <ref type="bibr">[4]</ref><ref type="bibr">[5]</ref><ref type="bibr">[6]</ref><ref type="bibr">27,</ref><ref type="bibr">28</ref> Most of these applications are at the lab-scale, with some recently emerging at the pilot-scale. The slow commercialization and scaling of these systems is in part due to the inefficiency of conventional BPMs. <ref type="bibr">6</ref> With the introduction of advanced BPMs into BPMED systems, the energy efficiency of the system should increase, allowing for higher current-density and increased product production rate which significantly lower capital costs of emerging BPMED and related technologies.</p><p>The construction of the BPMED and pure-water BPM electrolysis systems are related but differ in several important ways. For the BPMWE system, the BPM is subject to high and even internal pressure due to the catalyst and porous-transport layers (Figure <ref type="figure">1b</ref>). <ref type="bibr">9,</ref><ref type="bibr">29</ref> These porous-transport layers are typically made up of multiple packed nickel, steel, or titanium-woven fiber layers, or porous carbon, resulting in a relatively uniform surface. The BPMWE protocols used in this study, and for others from our team, were adopted from proton-exchange-membrane (PEM) electrolyzers. <ref type="bibr">12</ref> For PEM electrolyzers, increased compression enhances electrolyzer performance because of improved contact between the electrically conductive porous-transport layers and the ionically conductive membrane. <ref type="bibr">30,</ref><ref type="bibr">31</ref> However, if compression is too high, water transport through the PEM electrolyzer membrane is impeded and the system resistance increases. <ref type="bibr">32</ref> Despite the impacts of compression on PEM electrolyzer performance, there is little documented on the impact of compression on the BPM. This is interesting when using BPMs in BPMED systems that can provide a range of internal pressures as the spacers and materials used in the BPMED flow fields are changed (Figure <ref type="figure">S1</ref>). Within the BPMED system, flow-field spacers are typically course, single-layer weaves of inert plastic, such as polypropylene, with weave wire diameters ranging from &#8764;100 &#956;m to 1 mm and thus lead to uneven compression on the membrane surface. <ref type="bibr">24,</ref><ref type="bibr">33,</ref><ref type="bibr">34</ref> More broadly, little is known about the ideal compression of the BPMs in BPMED systems with regards to membrane performance, which relies heavily on the details of the BPM junction and membrane fabrication. <ref type="bibr">[34]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref> In addition to the different possible effects of static pressure on the BPM, there are differences in degradation and fouling mechanisms present in BPMED compared to BPMWE. BPMWE is often run with pure water contacting the BPM surface, while in BPMED the BPM is exposed to a range of differential electrolyte concentrations, compositions, and pHs. As the concentration of the solution contacting the AEL and/ or CEL making up the BPM increases, the membrane is less able to exclude the transport of co-ions (via Donnan exclusion) through the respective layers. <ref type="bibr">37,</ref><ref type="bibr">38</ref> The unwanted transport of co-ions may lead to fouling of the catalyst at the BPM junction, contamination of adjacent solutions, shunt currents, and surface contamination of the BPM as divalent ions precipitate at the BPM surface.</p><p>With these differences in mind, we report a lab-scale BPMED platform suitable for the study of potential drops throughout the BPMED system via the introduction of reference electrodes to the brine, acid, base, and electrolyte feed solutions (Figure <ref type="figure">2b</ref>). This platform enables the measurement of parameters such as &#951; wd to compare directly between the BPMWE and BPMED systems. We find that the new metal-oxide WD catalysts developed for use in BPMWE substantially lower the transmembrane voltage at a given current, due to lower &#951; wd , in the BPMED systems. The absolute &#951; wd , however, in the BPM electrodialysis devices are roughly twice that of the equivalent WD catalyst in the BPMWE devices at equivalent temperatures. These results are important because they demonstrate that the fundamental principles governing the performance of WD catalysts in advanced BPMs in the BPMWE system translate to the BPMED platform, despite the BPMED platform having co-ions present and a lower static pressure.</p><p>We also report current efficiency data for the advanced BPMs in BPMED compared to commercial Fumasep BPM.</p><p>Although the advanced BPMs were constructed with AEL and CEL designed for fuel cells and electrolyzers that typically have high H + and OH -ion conductivity, but lower permselectivity, current efficiency values were found to be on par with commercial Fumasep BPM. The good current efficiency found in the advanced BPMED system, particularly at the larger WD currents studied, may be due to the high efflux of and ions preventing the influx of unwanted co-ions. <ref type="bibr">39</ref> These findings thus demonstrate the feasibility of high current, nextgeneration BPMED stacks. With appropriate system engineering, these membranes may lower capital expenses by increasing the generation rate per area of acid and base for a variety of applications in water treatment, separations, and carbondioxide capture.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; HIGH-CURRENT BPM ELECTRODIALYSIS TEST CELL DESIGN AND OPERATION</head><p>A BPMED test cell was designed with several degrees of adjustability and monitoring capabilities to aid in understanding the BPMED system. This approach allows for the overall BPMED system to be broken down into six different circuits that record the potential drop across specific features of the BPMED system (Figure <ref type="figure">2</ref>). To record these individual circuits, reference electrodes were placed in the external solution reservoirs feeding the respective five solutions circulating through the BPMED system. Because current does not pass through the electrolyte in the tubing connecting the cell to the reservoirs, these are taken to be roughly equipotential and at an electric potential that is approximately equal to the average electric potential of the electrolyte flowing through the spacer-filled flow-field medium between each set of membranes.</p><p>Given this measurement scheme and approximation for electric-potential breakdown, the total potential changes relative to the open-circuit value, as a function of current, can be further broken down into their electrolyte, membrane, The color gradients schematically represent the potential gradients in each section of the electrodialysis stack. We take each reservoir (represented as the uniform-colored cylinders) as equipotential to the electrolyte at approximately the midpoint of the flow channel represented by the vertical dashed line. An ohmic potential drop is present across the electrolyte region and the membrane region of the system. The measured steady-state voltage changes also include contributions from concentration polarization in addition to contributions from electric-potential drops driving migration. Circuits A and F further include the reaction kinetic overpotentials which are not important in this study but contribute to the overall cell voltage.</p><p>or reaction overpotentials, depending on the circuit measured (Figure <ref type="figure">2b</ref>). Of particular interest to this study is circuit D, which contains the BPM, and thus the contribution of &#951; wd . Circuit D can be broken down into the overpotential across the BPM (&#916;&#981; BPM ), the acid solution (&#916;&#981; HCl ), and the base solution (&#916;&#981; NaOH ). The resistance (R) is calculated from the known conductivity (&#954;), length (l, along the current path), and A the area of the electrolyte flow channel.</p><p>To calculate the resistance of the electrolyte solutions (HCl and NaOH) in circuit D and the contributions of &#916;&#981; HCl and &#916;&#981; NaOH , &#954; for each is calculated from the ion concentrations of each solution and the reported molar conductivities. <ref type="bibr">40</ref> It was assumed that the reference electrodes were equipotential with the electrolyte exactly halfway across the spacer between the two membranes along the path of the current flow, which here is equal to half the thickness of the spacer mesh used in the BPMED system. Because the spacer mesh reduces the open volume of the electrolyte available for ionic current conduction, we define A electrolyte = geometric area &#215; f raction open area. We note that these calculations do not take into account boundary layer effects and associated concentration polarizations. <ref type="bibr">41</ref> Thus, the analysis implicitly assumes the turbulence of the spacer mesh, flow rate, and pH gradient are sufficient to prevent significant boundary-layer effects.</p><p>Further coupled fluid dynamics and migration/diffusion transport modeling of these systems will be useful as these assumptions likely break down at high current.</p><p>To obtain &#916;&#981; BPM , the &#916;&#981; HCl and &#916;&#981; NaOH values were subtracted from V i -V ocv measured across the reference electrodes. The term &#916;&#981; BPM can be further broken down into the potential drop across the solid CEL and AEL ionomer electrolytes (&#916;&#981; CEL and &#916;&#981; AEL ; respectively) and &#951; wd .</p><p>From the &#916;&#981; BPM values, membrane conductivities, determined via H-cell measurements, and thicknesses (l) were used to calculate and subtract &#916;&#981; CEL and &#916;&#981; AEL to provide &#951; wd .</p><p>= wd total,D HCl NaOH CEL AEL</p><p>&#9632; COMPARING PERFORMANCE VIA &#951; WD Using the presented BPMED platform, &#951; wd was compared between the BPMED and BPMWE systems. Controlling the WD catalyst loading following the procedures described previously, <ref type="bibr">10</ref> the catalyst loading was found to impact &#951; wd following similar trends between the two system types, where an increase in TiO 2 catalyst loading in a range of &#8764;0-100 &#956;g cm -2 led to reduced &#951; wd (Figure <ref type="figure">3a</ref>). Similar results were found for recently reported SnO 2 nanoparticle paste catalyst (Figure <ref type="figure">3b</ref>). <ref type="bibr">10,</ref><ref type="bibr">42</ref> To elucidate performance trends between the BPMWE and BPMED systems, the &#951; wd values at 0.5 A cm -2 were plotted versus TiO 2 catalyst loading (Figure <ref type="figure">3c</ref>). Both the BPM water electrolysis and electrodialysis experiments revealed a characteristic U-shape observed previously with optimal TiO 2 loading of &#8764;20 &#956;g cm -2 . <ref type="bibr">10</ref> This result suggests that advanced BPMs developed, and fundamentally understood, in a BPMWE system can be translated to more-complex systems like BPMED, allowing BPMWE systems to serve as an adequate development platform for BPMs in BPMED systems. The deviations in U-shape trends seen in Figure <ref type="figure">3c</ref> could be due to an inconsistent BPM construction at the lab-scale, impacts of co-ions from the soluble electrolytes on the physics of the BPM junction, or a difference in the static pressure on the BPM. Co-ion contaminants would increase ionic conductivity within the BPM junction, thus affecting the electric-field distribution by concentrating it more at the interfaces with AEL and CEL. <ref type="bibr">43</ref> This could result in a weaker dependence of &#951; wd on catalyst loading, similar to what is observed when adding electrically conductive media to the BPM junction. <ref type="bibr">10</ref> Changes in static pressure on the BPM may also lead to reduced water transport through the BPM as pressure is increased, following the trends seen in PEM electrolyzers and when determining conductivity of ionexchange membranes. <ref type="bibr">31,</ref><ref type="bibr">32</ref> Further, if reduced pressure leads to a less-compact BPM junction, the distance over which the electric potential drops will increase and the local electric field that is hypothesized to control water preorganization will decrease. <ref type="bibr">44</ref> Deconvoluting these possible differences, however, is not yet possible.</p><p>We also studied a recently reported low-temperature, nano-SnO 2 paste WD catalyst. A shallower U-shape curve of &#951; wd versus loading was observed (Figure <ref type="figure">3d</ref>). <ref type="bibr">42</ref> Like in BPMWE, the optimal loading of the SnO 2 was higher than for TiO 2 . The SnO 2 catalyst is more electrically conductive than the TiO 2 catalyst, perhaps the reason for the shallower U-shaped curve.</p><p>&#9632; COMPARING BPM PERFORMANCE VIA CURRENT EFFICIENCY Historically, production of a desired product (i.e., selectivity) was the primary goal of BPMED, but this often came at the expense of energy efficiency. <ref type="bibr">23,</ref><ref type="bibr">24</ref> One important measure of selectivity is current efficiency. Here, current efficiency is defined as the ratio of proton (or hydroxide ion) production experimentally versus the predicted production rate at a specific current density. This generation rate (G) can be using eq 6, where the current (i) passed through the system is converted to mol/s using the number of electrons transferred in the reaction (n) and Faraday's constant (F).</p><p>The generation rate is then used to determine the theoretical concentration change (&#916;C theo ) based on the amount of time (t) current was passed through the stack. The theoretical concentration change can be compared to the experimental concentration change (&#916;C exp ), as determined via titration, as described in eqs 7-9, providing a percent current efficiency (CE).</p><p>We measured current efficiency using the system described above to quantify the performance of BPMs. For this, the BPMED system was held at a constant current for 30 min, with base and acid samples titrated before and after this current hold to determine the change in pH in both the acid and base reservoirs associated with the total charge passed.</p><p>Figure <ref type="figure">4</ref> shows the current efficiency of the BPMED system for the optimally loaded TiO 2 BPM and SnO 2 BPM, as compared to a common commercial BPM from Fumasep. The TiO 2 BPM showed current efficiency values of &#8764;90% for both acid and base solutions across a current density range of 0.05-0.50 A cm -2 , while the SnO 2 BPM showed current efficiency values of &#8764;87% and 90% for acid and base, respectively (Figure <ref type="figure">4a</ref> and <ref type="figure">4b</ref>). A current efficiency value of &#8764;90% is consistent with the findings of Lucas et al., who used a similar BPMED system. <ref type="bibr">45</ref> Compared to Fumasep's BPM current efficiency values, the TiO 2 BPM performed slightly worse at low currents, 0.05-0.10 A cm -2 , and improved at higher currents, 0.25-0.50 A cm -2 . This trend could be due to higher flux of generated protons and hydroxide ions from the BPM junction at the higher currents, or related to the ionomer materials themselves. <ref type="bibr">46</ref> As current increases, the efflux of proton-and hydroxide-ion mobile species likely impedes the influx of coions, due to concentrated ion-ion interactions, thus increasing current efficiency at higher currents. <ref type="bibr">47</ref> This is an effect that we have previously noted, but requires further study to fully understand and engineer. <ref type="bibr">39</ref> Lucas et al. also noted reduced current efficiency at lower currents, attributing the trend to increasing co-ion transport across the BPM at these lower currents. Similarly, the SnO 2 BPM showed similar base current efficiency trends to TiO 2 , but showed a reduced acid current efficiency compared to both TiO 2 and Fumasep's BPM.</p><p>Substantial current efficiency loss can be expected given the unoptimized individual AEM and CEM that are used along with the BPM in the BPMED test platform. Because of the four-membrane configuration of this BPMED platform, current efficiency can also be reduced by ion-leakage across the supporting AEM and other two CEMs in the overall BPMED system (Figure <ref type="figure">4b</ref>). The loss of protons across the supporting AEM, for example, can lead to reduced acid current-efficiency values. The leakage of protons is difficult to prevent, and may explain the reduced current efficiency of the acid solution at high currents, compared to the basic-solution current efficiency. If the BPM ion-leakage was equivalent, then the acid and base solution current efficiencies should be the same. The optimization of the supporting AEM and CEM must be addressed in conjunction with advanced BPM integration in BPMED device cells and stacks. While the use of morepermselective membrane layers in the BPM itself might lead to further decreased co-ion crossover and thus higher current efficiencies as well, these initial findings show that the use of CELs and AELs developed for BPMWE applications can perform well in BPMED systems, especially at high-current densities.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; OVERALL IMPACT OF PERFORMANCE GAINS</head><p>Compared to the commercial Fumasep BPM, both the TiO 2 and SnO 2 catalyzed BPMs performed dramatically better with respect to energy consumption (Figure <ref type="figure">5a</ref>), with a nearly twofold decrease in energy consumption for the production of H + or OH -product. Furthermore, the durability of the SnO 2 catalyzed BPM is improved over the Fumasep BPM in the BPMED system tested, with Fumasep showing a degradation of &#8764;2.1 mV h -1 and SnO 2 showing a degradation of &#8764;0.3 mV h -1 (Figure <ref type="figure">5b</ref>). With these improvements, the catalyzed BPM can operate at higher current densities, while also providing higher product output at competitive efficiencies without compromising durability. These improvements may enable electrochemical stack systems to overcome economic barriers in applications like CO 2 electrolysis and brine remediation. However, detailed and application-specific techno-economic analyses are required to fully understand the impact of catalyszed BPMs on the viability of BPM containing technologies.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; CONCLUSION</head><p>We reported the initial translation of advanced, catalyzed BPMs from membrane-electrode assemblies to BPMED systems, showing that metal-oxide catalysts optimized in one system also improves performance in the other. The new catalyzed BPM provided current efficiency values for acidbase generation that exceeded those found for common commercial Fumasep BPM at current-densities above 0.20 A cm -2 , while requiring only roughly half of the driving voltage across the BPM. We also report a simple design for BPMED test platform that allows for the isolation of electrostatic potential drops across individual membranes in the system, allowing for the measurement of important characteristics like &#951; wd within the BPMED system. While further research is required to better understand the impacts of compression and possible co-ion fouling mechanisms in BPMWE-based BPM, the increased current densities in part enabled by the advanced BPMs are expected to facilitate broader adoption of BPMbased electrochemical technologies in electrodialysis-type platforms.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; ASSOCIATED CONTENT</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>* s&#305; Supporting Information</head><p>The Supporting Information is available free of charge at <ref type="url">https://pubs.acs.org/doi/10.1021/acsenergylett.4c03538</ref>.</p><p>Membranes and catalysts; advanced BPM fabrication; assembly of electrodialysis system with schematic illustrations; standard operating procedure for BMPED at Figshare:</p><p>10.6084/m9.figshare.28021250.v1; CAD and 3D printing files of BPMED system components at Figshare: 10.6084/m9.figshare.28021196.v1; laser cutting files for gaskets and spacer mesh at Figshare: 10.6084/m9.figshare.28021217.v1; procedure for data collection (electrochemical, polarization-curve, and current efficiency data) and corresponding LabView files at Figshare: 10.6084/m9.figshare.28021223.v1; determination of BPMED circuits A electrolyte ; titration of acid and base solutions; assembly of system for leak testing; determination of Nafion and Versogen conductivity; calculations for assessing energy consumption; procedure for stability test, post-mortem assessment of SnO 2 BPM from stability test with EDS line scan data; and comparison of total cell potential. (PDF) &#9632; AUTHOR INFORMATION Corresponding Author Shannon W. Boettcher -Oregon Center for Electrochemistry, Department of Chemistry and Biochemistry, University of Oregon, Eugene, Oregon 97403, United States; Department of Chemical &amp; Biomolecular Engineering and Department of Chemistry, University of California, Berkeley, California 94720, United States; Energy Storage and Distributed Resources Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States; orcid.org/ 0000-0001-8971-9123; Email: boettcher@berkeley.edu</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>https://doi.org/10.1021/acsenergylett.4c03538 ACS Energy Lett. 2025, 10, 845-852 Downloaded via UNIV OF OREGON on September 22, 2025 at 21:21:08 (UTC).See https://pubs.acs.org/sharingguidelines for options on how to legitimately share published articles.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_1"><p>https://doi.org/10.1021/acsenergylett.4c03538 ACS Energy Lett. 2025, 10, 845-852</p></note>
		</body>
		</text>
</TEI>
