Title: Inverse rendering of fusion plasmas: inferring plasma composition from imaging systems
Abstract In this work, we develop a differentiable rendering pipeline for visualising plasma emission within tokamaks, and estimating the gradients of the emission and estimating other physical quantities. Unlike prior work, we are able to leverage arbitrary representations of plasma quantities and easily incorporate them into a non-linear optimisation framework. The efficiency of our method enables not only estimation of a physically plausible image of plasma, but also recovery of the neutral Deuterium distribution from imaging and midplane measurements alone. We demonstrate our method with three different levels of complexity showing first that a poloidal neutrals density distribution can be recovered from imaging alone, second that the distributions of neutral Deuterium, electron density and electron temperature can be recovered jointly, and finally, that this can be done in the presence of realistic imaging systems that incorporate sensor cropping and quantisation.  more » « less
Award ID(s):
1909028
PAR ID:
10645193
Author(s) / Creator(s):
; ; ; ;
Corporate Creator(s):
Publisher / Repository:
IOP
Date Published:
Journal Name:
Nuclear Fusion
Volume:
65
Issue:
2
ISSN:
0029-5515
Page Range / eLocation ID:
026020
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Measurements of the plasma parameters of coronal mass ejections (CMEs), particularly the magnetic field and nonthermal electron population entrained in the CME plasma, are crucial to understand their propagation, evolution, and geo-effectiveness. Spectral modeling of gyrosynchrotron (GS) emission from CME plasma has been regarded as one of the most promising remote-sensing techniques for estimating spatially resolved CME plasma parameters. Imaging the very low flux density CME GS emission in close proximity to the Sun with orders of magnitude higher flux density has, however, proven to be rather challenging. This challenge has only recently been met using the high dynamic range imaging capability of the Murchison Widefield Array (MWA). Although routine detection of GS is now within reach, the challenge has shifted to constraining the large number of free parameters in GS models, a few of which are degenerate, using the limited number of spectral points at which the observations are typically available. These degeneracies can be broken using polarimetric imaging. For the first time, we demonstrate this using our recently developed capability of high-fidelity polarimetric imaging on the data from the MWA. We show that spectropolarimetric imaging, even when only sensitive upper limits on circularly polarization flux density are available, is not only able to break the degeneracies but also yields tighter constraints on the plasma parameters of key interest than possible with total intensity spectroscopic imaging alone. 
    more » « less
  2. A model for plasma confinement is developed and applied for describing an electrically confined thermonuclear plasma. The plasma confinement model includes both an analytical approach that excludes space charge effects and a classical trajectory Monte Carlo simulation that accounts for space charge. The plasma consists of reactant ions that form a non-neutral plasma without electrons. The plasma drifts around a negatively charged electrode. Conditions are predicted for confining a deuterium–tritium plasma using a 460 kV applied electric potential difference. The ion plasma would have a 20 keV temperature, a 1020 m−3 peak density, and a 110 keV average kinetic energy per ion (including drift and thermal portions at a certain point in the plasma). The fusion energy production rate is predicted to be 10 times larger than the energy loss rate, including contributions associated with both plasma loss to electrodes and secondary electron emission. However, an approach for enhancing the fusion power density may have to be employed to realize a practical use for centrifugal-electrostatic confinement fusion. 
    more » « less
  3. We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source. In addition, this work provides a detailed understanding of the plasma light measurement, which is one of the few diagnostic signals available for the direct measurement of PWFA plasma sources. 
    more » « less
  4. Abstract We use models of spectrally resolved cosmic-ray (CR) transport in TIGRESS MHD simulations of the local interstellar medium to produce synthetic synchrotron emission and to test, on scales from a few kiloparsecs down to ∼10 pc, the traditional estimate of magnetic field strength based on the assumption of equipartition between the magnetic and total CR energy densities. Our analysis shows that the traditional equipartition estimate works well at the kiloparsec scale of the simulation box, but breaks down at smaller scales. We find that the predicted magnetic field strength can be improved at small scales by assuming a constant CR energy density across each mock radio observation. The large-scale mean CR energy density can be estimated by assuming equipartition with the large-scale mean magnetic energy density, or as a function of additional observable quantities such as the star formation rate surface density or gas weight. In addition to estimating the magnetic field strength, we use synthetic polarized emission to create maps of the magnetic field direction. We find that the true magnetic field direction can be recovered well from the mock observations. 
    more » « less
  5. Abstract The active-particle number density is a key parameter for plasma material processing, space propulsion, and plasma-assisted combustion. The traditional actinometry method focuses on measuring the density of the atoms in the ground state, but there is a lack of an effective optical emission spectroscopy method to measure intra-shell excited-state densities. The latter atoms have chemical selectivity and higher energy, and they can easily change the material morphology as well as the ionization and combustion paths. In this work, we present a novel state-resolved actinometry (SRA) method, supported by a krypton line-ratio method for the electron temperature and density, to measure the number densities of nitrogen atoms in the ground and intra-shell excited states. The SRA method is based on a collisional-radiative model, considering the kinetics of atomic nitrogen and krypton including their excited states. The densities measured by our method are compared with those obtained from a dissociative model in a miniature electron cyclotron resonance (ECR) plasma source. Furthermore, the saturation effect, in which the electron density remains constant due to the microwave propagation in an ECR plasma once the power reaches a certain value, is used to verify the electron density measured by the line-ratio method. An ionization balance model is also presented to examine the measured electron temperature. All the values obtained with the different methods are in good agreement with each other, and hence a set of verified rate coefficient data used in our method can be provided. A novel concept, the ‘excited-state system’, is presented to quickly build an optical diagnostic method based on the analysis of quantum number propensity and selection rules. 
    more » « less