Title: Repurposing Portable Gas Chromatograph–Mass Spectrometers for Detecting Volatile Organic Compound Biomarkers in Urine Headspace
Volatile organic compounds (VOCs) in urine headspace are potential biomarkers for different medical conditions, as canines can detect human diseases simply by smelling VOCs. Because dogs can detect disease-specific VOCs, gas chromatography–mass spectrometry (GC–MS) systems may be able to differentiate medical conditions with enhanced accuracy and precision, given they have unprecedented efficiency in separating, quantifying, and identifying VOCs in urine. Advancements in instrumentation have permitted the development of portable GC–MS systems that analyze VOCs at the point of care, but these are designed for environmental monitoring, emergency response, and manufacturing/processing. The purpose of this study is to repurpose the HAPSITE® ER portable GC–MS for identifying urinary VOC biomarkers. Method development focused on optimizing sample preparation, off-column conditions, and instrumental parameters that may affect performance. Once standardized, the method was used to analyze a urine standard (n = 10) to characterize intra-day reproducibility. To characterize inter-day performance, n = 3 samples each from three volunteers (and the standard) were analyzed each day for a total of four days (n = 48 samples). Results showed the method could detect VOC signals with adequate reproducibility and distinguish VOC profiles from different volunteers with 100% accuracy.  more » « less
Award ID(s):
1950672
PAR ID:
10654626
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
MDPI
Date Published:
Journal Name:
Separations
Volume:
12
Issue:
5
ISSN:
2297-8739
Page Range / eLocation ID:
118
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Harnessing the potential of exhaled breath analysis is an emerging frontier in medical diagnostics, given breath is a rich source of volatile organic compound (VOC) biomarkers for different medical conditions. A current downfall in this field, however, is the lack of standardized and widely available methods for offline sampling of exhaled VOCs. Herein, strides are taken toward the standardization of breath sampling in Tedlar bags by exploring several factors that can impact VOC heterogeneity, including tubing material, chemical composition of collection bags, breath fractionation, exhalation volume, and transfer flow rate. After bag-based sampling standardization, performance was benchmarked using two offline breath sampling methods, Tedlar bags and the Respiration Collector for In Vitro Analysis (ReCIVA). Three volunteers from the laboratory with no known respiratory diseases donated ≥ n = 5 samples collected onto adsorption tubes via each method, which were analyzed through thermal desorption (TD) coupled with gas chromatography-mass spectrometry (GC–MS). Data processing revealed a set of 15 highly reliable on-breath VOCs detected across volunteers, and most analytes (except indole) demonstrated higher sensitivity using Tedlar bags. Calculating relative standard deviation (RSD) values showed Tedlar bags were also significantly more reproducible compared to the ReCIVA (p < 0.03). Agreement between the two methods was demonstrated through correlating VOC signals with high statistical significance (R2 = 0.70), indicating both devices are well situated for biomarker discovery applications. 
    more » « less
  2. Sanchez, Leandro F; Trottier, Cassandra (Ed.)
    For millennia, the medical field has utilized the sense of smell for qualitative assessment of health, but recent research shows we can tap into volatile organic compounds (VOCs), which create the odors that we perceive, for quantitative detection and analysis. In this paper, volatile organic compounds produced by the microbes in aged concrete, actively undergoing deterioration due to alkali-silica reaction were analyzed. Volatile organic compounds metabolites, an oft unused resource of chemical information that are produced by concrete-associated microbial communities, were used to detect, and characterize concrete deterioration. In this talk, preliminary results of volatile detection on long-term samples (e.g., ~ 7 years) will be provided. Scanning electron microscopy with energy disperse x-ray analysis was used to confirm deterioration mechanisms identified using volatilomics. Volatiles were analyzed using direct thermal extraction (DTE) and comprehensive two-dimensional gas chromatography - time-of-flight mass spectrometry (GC × GC–TOFMS). Identifying VOC biomarkers of concrete health will lay the groundwork for the development of sensors that can provide early deterioration warning, enabling more effective remediation/repair strategies. Microbes may also be sensitive to environmental stress (e.g., climate change), and a sensor based on microbial volatile organic compounds could be used to monitor infrastructure health and provide data to detect environmental stressors relevant to other fields. 
    more » « less
  3. null (Ed.)
    ABSTRACT Current methods for non-invasive prostate cancer (PrCa) detection have a high false-positive rate and often result in unnecessary biopsies. Previous work has suggested that urinary volatile organic compound (VOC) biomarkers may be able to distinguish PrCa cases from benign disease. The behavior of the nematode Caenorhabditis elegans has been proposed as a tool to take advantage of these potential VOC profiles. To test the ability of C. elegans Bristol N2 to distinguish PrCa cases from controls, we performed chemotaxis assays using human urine samples collected from men screened for PrCa. Behavioral response of nematodes towards diluted urine from PrCa cases was compared to response to samples from cancer-free controls. Overall, we observed a significant attraction of young adult-stage C. elegans nematodes to 1:100 diluted urine from confirmed PrCa cases and repulsion of C. elegans to urine from controls. When C. elegans chemotaxis index was considered alongside prostate-specific antigen levels for distinguishing cancer from cancer-free controls, the accuracy of patient classification was 81%. We also observed behavioral attraction of C. elegans to two previously reported VOCs to be increased in PrCa patient urine. We conclude nematode behavior distinguishes PrCa case urine from controls in a dilution-dependent manner. 
    more » « less
  4. Abstract We present emission measurements of volatile organic compounds (VOCs) for western U.S. wildland fires made on the NSF/NCAR C‐130 research aircraft during the Western Wildfire Experiment for Cloud Chemistry, Aerosol Absorption, and Nitrogen (WE‐CAN) field campaign in summer 2018. VOCs were measured with complementary instruments onboard the C‐130, including a proton‐transfer‐reaction time‐of‐flight mass spectrometer (PTR‐ToF‐MS) and two gas chromatography (GC)‐based methods. Agreement within combined instrument uncertainties (<60%) was observed for most co‐measured VOCs. GC‐based measurements speciated the isomeric contributions to selected PTR‐ToF‐MS ion masses and generally showed little fire‐to‐fire variation. We report emission ratios (ERs) and emission factors (EFs) for 161 VOCs measured in 31 near‐fire smoke plume transects of 24 specific individual fires sampled in the afternoon when burning conditions are typically most active. Modified combustion efficiency (MCE) ranged from 0.85 to 0.94. The measured campaign‐average total VOC EF was 26.1 ± 6.9 g kg−1, approximately 67% of which is accounted for by oxygenated VOCs. The 10 most abundantly emitted species contributed more than half of the total measured VOC mass. We found that MCE alone explained nearly 70% of the observed variance for total measured VOC emissions (r2 = 0.67) and >50% for 57 individual VOC EFs representing more than half the organic carbon mass. Finally, we found little fire‐to‐fire variability for the mass fraction contributions of individual species to the total measured VOC emissions, suggesting that a single speciation profile can describe VOC emissions for the wildfires in coniferous ecosystems sampled during WE‐CAN. 
    more » « less
  5. Detecting volatile organic compounds (VOCs) is increasingly recognized as a pivotal tool in non-invasive disease diagnostics. VOCs are metabolic byproducts, mostly found in human breath, urine, feces, and sweat, whose profiles may shift significantly due to pathological conditions. This paper presents a thorough review of the latest advancements in sensor technologies for VOC detection, with a focus on their healthcare applications. It begins by introducing VOC detection principles, followed by a review of the rapidly evolving technologies in this area. Special emphasis is given to functionalized molecularly imprinted polymer-based biochemical sensors for detecting breath biomarkers, owing to their exceptional selectivity. The discussion examines SWaP-C considerations alongside the respective advantages and disadvantages of VOC sensing technologies. The paper also tackles the principal challenges facing the field and concludes by outlining the current status and proposing directions for future research. 
    more » « less