Title: Multi-parametric thrombus profiling microfluidics detects intensified biomechanical thrombogenesis associated with hypertension and aging
Abstract Arterial thrombosis is a leading cause of death and disability worldwide with no effective bioassay for clinical prediction. As a symbolic feature of arterial thrombosis, severe stenosis in the blood vessel creates a high-shear, high-gradient flow environment that facilitates platelet aggregation towards vessel occlusion. Here, we present a thrombus profiling assay that monitors the multi-dimensional attributes of thrombi forming in such biomechanical conditions. Using this assay, we demonstrate that different receptor–ligand interactions contribute distinctively to the composition and activation status of the thrombus. Our investigation into hypertensive and older individuals reveals intensified biomechanical thrombogenesis and multi-dimensional thrombus profile abnormalities, endorsing the diagnostic potential of the assay. Furthermore, we identify the hyperactivity of GPIbα-integrin αIIbβ3mechanosensing axis as a molecular mechanism that contributes to hypertension-associated arterial thrombosis. By studying drug-disease interactions and inter-individual variability, our work reveals a need for personalized anti-thrombotic drug selection that accommodates each patient’s pathological profile.  more » « less
Award ID(s):
2047072
PAR ID:
10665806
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; ; ; « less
Publisher / Repository:
Nature Portfolio
Date Published:
Journal Name:
Nature Communications
Volume:
15
Issue:
1
ISSN:
2041-1723
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract von Willebrand factor (VWF) is essential for the induction of arterial thrombosis. In this study, we investigated the critical role of platelet VWF in occlusive thrombosis formation at high shear in mice that do not express platelet VWF (Nbeal2−/−). Using in silico modeling, in vitro high-shear microfluidics, and an in vivo Folts model of arterial thrombosis we reproduced the platelet dynamics that occur under pathological flow in a stenosed vessel. Computational fluid dynamics (CFDs) simulated local hemodynamics in a stenosis based on arterial geometries. The model predicted shear rates, time course of platelet adhesion, and time to occlusion. These predictions were validated in vitro and in vivo. Occlusive thrombosis developed in wild-type control mice that had normal levels of plasma VWF and platelet VWF in vitro and in vivo. Occlusive thrombosis did not form in the Nbeal2−/− mice that had normal plasma VWF and an absence of platelet VWF. Occlusive thrombosis was corrected in Nbeal2−/− microfluidic assays by the addition of exogenous normal platelets with VWF. Combining model and experimental data, we demonstrated the necessary requirement of platelet VWF in α-granules in forming an occlusive thrombus under high shear. These results could inspire new pharmacological targets specific to pathological conditions and prevent arterial thrombosis. 
    more » « less
  2. ABSTRACT Fibrin's dual role, as a transient scaffold guiding wound repair and as a pathogenic matrix in thrombosis, demands tools that can profile how its transport properties, degradability, and cellular remodeling evolve under different biochemical, engineering, and ultimately patient‐specific conditions. Here, we introduce a single‐channel, H‐junction microfluidic platform that enables multiplexed, real‐time quantification of fibrin permeability, fibrinolysis kinetics, fibroblast invasion, and clot extension within the same hydrogel. Using time‐lapse confocal microscopy, the assay captured solute permeability coefficients from 1.98 × 10−5to 1.67 × 10−4cm2∙s−1, fibrinolysis half‐times down to 12 min, and cell migration, with quantitative analysis performed in a ∼3 µL gel volume. Systematic variation of fibrinogen concentration (1.5–10 mg∙mL−1) and FXIII crosslink density reveals a 3.7‐fold span in permeability, a ninefold shift in lysis rate, and up to 64% suppression of fibroblast penetration, as fibrinogen concentration increases. Because the chip uses standard soft‐lithography and conventional microscopy tools, it can be integrated into existing microphysiological systems or deployed as a high‐throughput screening tool for anticoagulants, pro‐healing therapies, and patient‐specific risk assessment. This versatile platform thus bridges mechanistic fibrin research and translational biomaterials design, opening new avenues for precision thrombosis modelling and regenerative medicine. 
    more » « less
  3. ABSTRACT ObjectiveThis study demonstrates the impact of alterations in pressure, vascular compliance, arterial pulsatility, and autoregulation on tissue perfusion following middle cerebral artery (MCA) occlusion using mathematical modeling. MethodsOur previous mathematical model of the cerebral circulation is expanded to include vessel compliance and pulsatility of blood flow. An experimentally‐obtained pressure waveform is used as an incoming boundary condition to simulate the effects of vascular compliance and pulsatility of flow on perfusion following MCA occlusion. The waveform is adjusted to model the effects of elevated mean arterial pressure. ResultsIncreased distensibility reduces the amplitude of oscillations in the time‐dependent pressure solutions, whereas decreased distensibility produces more variation in these pressures. Occlusion significantly alters the magnitude of flow changes when incoming pressure is varied. The addition of the pulsatile pressure boundary condition and capacitances in the arteries and veins shifts the autoregulation plateau to higher pressures. ConclusionsThis study reveals how changes in incoming pressure affect compensatory responses to ischemic stroke caused by MCA occlusion. Boundary conditions corresponding to elevated mean arterial pressures are associated with lower degrees of ischemia, an improvement that is supported by changes in autoregulation patterns following occlusion. The results also demonstrate how increases in arterial stiffness associated with aging can inhibit the ability of the vasculature to accommodate pulsatile flow by analyzing resulting patterns such as larger amplitudes of pressure and flow oscillations in the microcirculation. The study provides a foundation for modeling the relationships among vessel compliance, arterial blood pressure, and cerebrovascular conditions. 
    more » « less
  4. AbstractOne‐dimensional (1D) cardiovascular models offer a non‐invasive method to answer medical questions, including predictions of wave‐reflection, shear stress, functional flow reserve, vascular resistance and compliance. This model type can predict patient‐specific outcomes by solving 1D fluid dynamics equations in geometric networks extracted from medical images. However, the inherent uncertainty inin vivoimaging introduces variability in network size and vessel dimensions, affecting haemodynamic predictions. Understanding the influence of variation in image‐derived properties is essential to assess the fidelity of model predictions. Numerous programs exist to render three‐dimensional surfaces and construct vessel centrelines. Still, there is no exact way to generate vascular trees from the centrelines while accounting for uncertainty in data. This study introduces an innovative framework employing statistical change point analysis to generate labelled trees that encode vessel dimensions and their associated uncertainty from medical images. To test this framework, we explore the impact of uncertainty in 1D haemodynamic predictions in a systemic and pulmonary arterial network. Simulations explore haemodynamic variations resulting from changes in vessel dimensions and segmentation; the latter is achieved by analysing multiple segmentations of the same images. Results demonstrate the importance of accurately defining vessel radii and lengths when generating high‐fidelity patient‐specific haemodynamics models.image Key pointsThis study introduces novel algorithms for generating labelled directed trees from medical images, focusing on accurate junction node placement and radius extraction using change points to provide haemodynamic predictions with uncertainty within expected measurement error.Geometric features, such as vessel dimension (length and radius) and network size, significantly impact pressure and flow predictions in both pulmonary and aortic arterial networks.Standardizing networks to a consistent number of vessels is crucial for meaningful comparisons and decreases haemodynamic uncertainty.Change points are valuable to understanding structural transitions in vascular data, providing an automated and efficient way to detect shifts in vessel characteristics and ensure reliable extraction of representative vessel radii. 
    more » « less
  5. Abstract PurposeThis study aims to characterize the dependence of measured retinal arterial and venous saturation on vessel diameter and central reflex in retinal oximetry, with an ultimate goal of identifying potential causes and suggesting approaches to improve measurement accuracy. MethodsIn 10 subjects, oxygen saturation, vessel diameter and optical density are obtained using Oxymap Analyzer software without diameter correction. Diameter dependence of saturation is characterized using linear regression between measured values of saturation and diameter. Occurrences of negative values of vessel optical densities (ODs) associated with central vessel reflex are acquired from Oxymap Analyzer. A conceptual model is used to calculate the ratio of optical densities (ODRs) according to retinal reflectance properties and single and double‐pass light transmission across fixed path lengths. Model‐predicted values are compared with measured oximetry values at different vessel diameters. ResultsVenous saturation shows an inverse relationship with vessel diameter (D) across subjects, with a mean slope of −0.180 (SE = 0.022) %/μm (20 < D < 180 μm) and a more rapid saturation increase at small vessel diameters reaching to over 80%. Arterial saturation yields smaller positive and negative slopes in individual subjects, with an average of −0.007 (SE = 0.021) %/μm (20 < D < 200 μm) across all subjects. Measurements where vessel brightness exceeds that of the retinal background result in negative values of optical density, causing an artifactual increase in saturation. Optimization of model reflectance values produces a good fit of the conceptual model to measured ODRs. ConclusionMeasurement artefacts in retinal oximetry are caused by strong central vessel reflections, and apparent diameter sensitivity may result from single and double‐pass transmission in vessels. Improvement in correction for vessel diameter is indicated for arteries however further study is necessary for venous corrections. 
    more » « less