Title: Comparison of Red (785 nm) and Blue (457 nm) Excitation Lasers for Raman Analysis of Synthetic and Natural Calcium Carbonate Samples
ABSTRACT Raman spectroscopy has become a prominent analytical technique in calcium carbonate geochemistry, crystallography, and mineralogy. Many Raman‐based calcium carbonate studies have commonly utilized the 785‐nm (near‐infrared or “red”) excitation laser for its relatively high scattering intensities (peak intensities) and low background fluorescence. Although the 457‐nm (blue) laser has a theoretically higher spatial resolution due to its lower wavelength and experiences relatively less background fluorescence compared to the 532‐nm (green) laser, it remains largely unused and untested for Raman analyses of calcium carbonate crystals. Here, we performed comparative Raman analyses (area mapping and vertical profiling) on various abiogenic and biogenic aragonite and calcite samples to assess spatial resolution differences in acquired Raman spectral data (ν1full width at half maximum or FWHM, Raman shift, and peak intensity) between the red and blue excitation laser settings. Area maps and vertical profiles demonstrate that analyses with the blue laser provide higher lateral and vertical spatial resolution than those with the red laser, likely due to the smaller lateral spot size and depth penetration of the blue laser. We also performed spot measurements on precipitated aragonite samples from previous studies, which generated distinct trend lines between ν1FWHM and aragonite saturation state (ΩArag) for specific excitation laser wavelengths and instrument models. Blue excitation lasers provide a mode of producing higher quality Raman area maps, which will be useful for high‐resolution spatial analyses on natural and synthetic calcium carbonate samples known to contain crystallographic and structural heterogeneity.  more » « less
Award ID(s):
2323221 2446763
PAR ID:
10668295
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  
Publisher / Repository:
John Wiley & Sons Ltd
Date Published:
Journal Name:
Journal of Raman Spectroscopy
ISSN:
0377-0486
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract: Data and R code used in generating the figures (both main text and supporting information) included in the article "Comparison of red (785 nm) and blue (457 nm) excitation lasers for Raman analysis of synthetic and natural calcium carbonate samples", to be submitted to the Journal of Raman Spectroscopy.  Data folders are organized by figure number. Within the R code, please set the working directory accordingly with your own computer's folders, file paths, etc. Please also carefully refer to the commented lines for directions on setting up the various plotting code templates for specific figure types.  Version 2 update (9/1/25) includes new axis titles and new supporting information figure added during manuscript review. 
    more » « less
  2. Periasamy, Ammasi; So, Peter T.; König, Karsten (Ed.)
    Using the structured illumination, single pixel detection imaging technique SPatIal Frequency modulation Imaging (SPIFI), we demonstrate a cascaded Wavelength Domain and Spatial Domain (WD-SD-SPIFI) system enabling real-time, in-line, second order dispersion compensation optimization for multiphoton imaging. Enhanced resolution is demonstrated by imaging a sub-diffractive 140 nm fluorescent nanodiamond with Two Photon Excitation Fluorescence (2PEF) to measure the Point Spread Function (PSF). With a 1034 nm pulsed laser through a Numerical Aperture (NA) of 0.5, a PSF Full Width at Half Max (FWHM) of 780 nm was measured with minimal post processing analysis that only requires Fast Fourier Transforms (FFTs). 
    more » « less
  3. The intrinsic fluorescence of bacterial samples has a proven potential for label-free bacterial characterization, monitoring bacterial metabolic functions, and as a mechanism for tracking the transport of relevant components through vesicles. The reduced scattering and axial confinement of the excitation offered by multiphoton imaging can be used to overcome some of the limitations of single-photon excitation (e.g., scattering and out-of-plane photobleaching) to the imaging of bacterial communities. In this work, we demonstrate in vivo multi-photon microscopy imaging of Streptomyces bacterial communities, based on the excitation of blue endogenous fluorophores, using an ultrafast Yb-fiber laser amplifier. Its parameters, such as the pulse energy, duration, wavelength, and repetition rate, enable in vivo multicolor imaging with a single source through the simultaneous two- and three-photon excitation of different fluorophores. Three-photon excitation at 1040 nm allows fluorophores with blue and green emission spectra to be addressed (and their corresponding ultraviolet and blue single-photon excitation wavelengths, respectively), and two-photon excitation at the same wavelength allows fluorophores with yellow, orange, or red emission spectra to be addressed (and their corresponding green, yellow, and orange single-photon excitation wavelengths). We demonstrate that three-photon excitation allows imaging over a depth range of more than 6 effective attenuation lengths to take place, corresponding to an 800 micrometer depth of imaging, in samples with a high density of fluorescent structures. 
    more » « less
  4. Abstract We confirm the Raman origin of the singlet oxygen photogenerated in water environments without using photosensitizers. Nanosecond light pulses in the blue region of the spectra (405–480 nm) generate Raman Stokes excitation of singlet oxygen in the red region (600–670 nm) when focusing on pure distilled water. The excitation also produces Stokes components corresponding to the stretching modes of water molecules. The time evolution of both types of Stokes components, singlet oxygen, and stretching modes correspond to the time duration of the excitation pulse as expected for a Raman process. Their power dependences are also similar. Finally, both signals exhibit high refractive ring structures due to the nonlinear optical interaction generated by the stimulated Raman process. 
    more » « less
  5. null (Ed.)
    A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements. 
    more » « less