The global challenge of water scarcity has fueled significant interest in membrane desalination, particularly reverse osmosis (RO), for producing fresh water from various unconventional sources. However, mineral scaling remains a critical issue that compromises the membrane efficiency and lifespan. This study explores the use of naturally occurring proteins to develop scaling resistant RO membranes through an eco-friendly modification method. We systematically evaluate three protein modification techniques, namely, polydopamine (PDA)-assisted coating, protein conditioning, and protein drying, for fabricating membranes resistant to gypsum scaling. Protein conditioning is found to be the most effective approach, resulting in protein-decorated membranes with an exceptional resistance to gypsum scaling. We also demonstrate that a hydrated protein layer is essential for optimal scaling resistance. To further understand the mechanism underlying the scaling resistance of protein-decorated membranes, five proteins (i.e., bovine serum albumin, casein, lactalbumin, lysozyme, and protamine) with distinct physicochemical properties are used to explore the key factors governing membrane scaling resistance. The results of dynamic RO experiments indicate that the molecular weight of proteins plays a crucial role, with higher molecular weights leading to higher membrane scaling resistance through steric effects. However, static experiments of bulk crystallization highlight the importance of electrostatic interactions, where proteins with more negative charge delay gypsum crystallization more effectively. These findings suggest the difference between gypsum scaling in the RO and gypsum crystallization in bulk solutions. Overall, this research offers a novel approach to developing resilient and sustainable RO membranes for the desalination of feedwater with high scaling potential while elucidating mechanistic insights on the mitigating effects of protein on gypsum scaling.
more »
« less
Modeling-Based Comparison of Gypsum Scaling Potential between Reverse Osmosis and Electrodialysis for Brackish Water Desalination
Brackish water desalination offers a sustainable solution to water scarcity, but mineral scaling such as gypsum scaling poses a major operational challenge. While electrodialysis (ED) has emerged as a promising alternative to reverse osmosis (RO) for brackish water desalination, the propensity to mineral scaling has not been systematically compared between these two processes. This study employs a process modeling approach to compare gypsum scaling propensity between RO and ED, focusing on a low feed salinity regime (∼3 g L–1). Gypsum scaling is evaluated in RO as a function of water recovery, applied pressure, and membrane water permeance, while it is assessed in ED for the concentrate stream as a function of salt removal under varying cell pair voltages and water recoveries. Results reveal that increasing applied pressure or membrane water permeance intensifies gypsum scaling in RO and reduces the water recovery at gypsum saturation. In ED, co-ions and counterions exhibit distinct behaviors of accumulation near the membrane surface, with scaling potential increasing at higher water recovery and lower cell pair voltage. At consistent system productivity, gypsum scaling imposes a more significant constraint on RO than ED, highlighting the potential of ED as a more robust alternative to RO and informing technology selection and optimization in brackish water desalination.
more »
« less
- Award ID(s):
- 2504116
- PAR ID:
- 10672736
- Publisher / Repository:
- American Chemical Society
- Date Published:
- Journal Name:
- ACS ES&T Engineering
- Volume:
- 5
- Issue:
- 11
- ISSN:
- 2690-0645
- Page Range / eLocation ID:
- 3007 to 3017
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Reverse osmosis (RO), as an energy efficient desalination technology that is critical to mitigate water scarcity, encounters feedwater containing both organic foulants and inorganic scalants. However, comparing with extensive studies on individual fouling or scaling, our knowledge of the behavior and mechanisms associated with combined organic fouling and mineral scaling is still lacking. Due to the potential occurrence of mineral formation in both bulk solution and on the membrane surface, a complete, mechanistic understanding of combined fouling and scaling requires decoupling of surface and bulk phenomena. Herein, our study employed a comprehensive investigation to delve into the intricate interplay of gypsum scaling and organic fouling in RO process. Our systematic approach is accomplished through three sets of experiments that include static experiments and two types of dynamic experiments (i.e., (1) combined fouling and scaling, and (2) gypsum scaling on foulant-conditioned membranes). A variety of model foulants including humic acid, alginate, bovine serum albumin (BSA), and lysozyme were used to investigate the effects of foulant type. Our results demonstrate that the behavior of combined organic fouling and gypsum scaling aligns more with that of gypsum scaling on foulant-conditioned membranes rather than static experiments where bulk nucleation occurs, indicating the predominance of surface nucleation in RO. BSA exhibited a remarkable hindering effect on gypsum scaling, whereas other foulants displayed an additive effect. The lack of scaling mitigation by lysozyme suggests that molecular properties of protein must play a role in regulating the behavior of combined fouling and scaling. Results from multiple characterization techniques reveal the foulant-scalant interactions by delineating the morphological and chemical features of the fouling/scaling layers. Our study not only elucidates the mechanisms of combined organic fouling and gypsum scaling but also sheds light on potential strategies for membrane scaling control in RO desalination.more » « less
-
Electrocoagulation as a pretreatment for reverse osmosis for potable water from brackish groundwaterReverse osmosis (RO) is a widely utilized method for water treatment and desalination. Our study examined the application of an electrocoagulation (EC) and RO hybrid system for treating actual brackish groundwater (BGW), focusing on reducing RO scaling by EC pretreatment. A series of EC operating conditions were investigated, such as applied voltage, pH, EC reaction time, and type of electrode. The commercial software WAVE was utilized to analyze the water quality to assess the scaling potential of the EC pretreated feed stream for the San Antonio Water System (SAWS) BGW desalination plant. The SAWS BGW desalination process involves a three-stage RO process. Our findings indicate that pretreatment with EC effectively prevents membrane scaling when compared to feed without EC. We conducted continuous EC experiments which showed stable performance and the potential for future commercialization.more » « less
-
Abstract Mineral scaling represents a major constraint that limits the efficiency of membrane desalination, which is becoming increasingly important for achieving sustainable water supplies in the context of a changing climate. Different mineral scales can be formed via distinct mechanisms that lead to a significant variation of scaling behaviors and mitigation strategies. In this article, we present a comprehensive review that thoroughly compares gypsum scaling and silica scaling, which are two common scaling types formed via crystallization and polymerization respectively, in membrane desalination. We show that the differences between scale formation mechanisms greatly affect the thermodynamics, kinetics, and mineral morphology of gypsum scaling and silica scaling. Then we review the literatures on the distinct behaviors of gypsum scaling and silica scaling during various membrane desalination processes, examining their varied damaging effects on desalination efficiency. We further scrutinize the different interactions of gypsum and silica with organic foulants, which result in contrasting consequences of combined scaling and fouling. In addition, the distinctive mitigation strategies tailored to controlling gypsum scaling and silica scaling, including scaling-resistant membrane materials, antiscalants, and pretreatment, are discussed. We conclude this article with the research needs of attaining a better understanding of different mineral scaling types, aiming to inspire researchers to take scale formation mechanism into consideration when developing more effective approaches of scaling control in membrane desalination.more » « less
-
Silica scaling is a major type of mineral scaling that significantly constrains the performance and efficiency of membrane desalination. While antiscalants have been commonly used to control mineral scaling formed via crystallization, there is a lack of antiscalants for silica scaling due to its unique formation mechanism of polymerization. In this study, we performed a systematic study that investigated and compared antiscalants with different functional groups and molecular weights for mitigating silica scaling in membrane distillation (MD) and reverse osmosis (RO). The efficiencies of these antiscalants were tested in both static experiments (for hindering silicic acid polymerization) as well as crossflow, dynamic MD and RO experiments (for reducing water flux decline). Our results show that antiscalants enriched with strong H-accepters and H-donors were both able to hinder silicic acid polymerization efficiently in static experiments, with their antiscaling performance being a function of both molecular functionality and weight. Although poly(ethylene glycol) (PEG) with abundant H-accepters exhibited high antiscaling efficiencies during static experiments, it displayed limited performance of mitigating silica scaling during MD and RO. Poly (ethylene glycol) diamine (PEGD), which has a PEG backbone but is terminated by two amino groups, was efficient to both hinder silicic acid polymerization and reduce water flux decline in MD and RO. Antiscalants enriched with H-donors, such as poly(ethylenimine) (PEI) and poly(amidoamine) (PAMAM), were effective of extending the water recovery of MD but conversely facilitated water flux decline of RO in the presence of supersaturated silica. Further analyses of silica scales formed on the membrane surfaces confirmed that the antiscalants interacted with silica via hydrogen bonding and showed that the presence of antiscalants governed the silica morphology. Our work indicates that discrepancy in antiscalant efficiency exists between static experiments and dynamic membrane filtration as well as between different membrane processes associated with silica scaling, providing valuable insights on the design principle and mechanisms of antiscalants tailored to silica scaling.more » « less