Abstract Data centers have complex environments that undergo constant changes due to fluctuations in IT load, commissioning and decommissioning of IT equipment, heterogeneous rack architectures and varying environmental conditions. These dynamic factors often pose challenges in effectively provisioning cooling systems, resulting in higher energy consumption. To address this issue, it is crucial to consider data center thermal heterogeneity when allocating workloads and controlling cooling, as it can impact operational efficiency. Computational Fluid Dynamics (CFD) models are used to simulate data center heterogeneity and analyze the impact of two different cooling mechanisms on operational efficiency. This research focuses on comparing the cooling based on facility water for Rear Door Heat Exchanger (RDHx) and conventional Computer Room Air Conditioning (CRAH) systems in two different data center configurations. Efficiency is measured in terms of ΔT across facility water. Higher ΔT will result in efficient operation of chillers. The actual chiller efficiency is not calculated as it would depend on local ambient conditions in which the chiller is operated. The first data center model represents a typical enterpriselevel configuration where all servers and racks have homogeneous IT power. The second model represents a colocation facility where server/rack power configurations are randomly distributed. These models predict temperature variations at different locations based on IT workload and cooling parameters. Traditionally, CRAH configurations are selected based on total IT power consumption, rack power density, and required cooling capacity for the entire data center space. On the other hand, RDHx can be scaled based on individual rack power density, offering localized cooling advantages. Multiple workload distribution scenarios were simulated for both CRAH and RDHx-based data center models. The results showed that RDHx provides a uniform thermal profile across the data center, irrespective of server/rack power density or workload distribution. This characteristic reduces the risk of over- or under-provisioning racks when using RDHx. Operational efficiency is compared in terms of difference in supply and return temperature of facility water for CRAH and RDHx units based on spatial heat dissipation and workload distribution. RDHx demonstrated excellent cooling capabilities while maintaining a higher ΔT, resulting in reduced cooling energy consumption, operational carbon footprint (?), and water usage.
more »
« less
The relationship between data centers and the climate is a systems challenge: a spatial analysis of United States data centers
Abstract Data centers are a rapidly growing infrastructure that support digital and artificial intelligence needs. However, their expansion has raised concerns about impact based on electricity and water usage. Beyond quantifying the impact of the data center on the environment, this study presents an energy-climate operational risk analysis of over 2,400 data centers in the United States, focusing on location-specific water and heat risks and the dependency of emissions on local energy mixes. Findings highlight that current framing around the sustainability and reliability of data center operations could benefit from systems approaches for a more holistic understanding. We find that many data centers are in regions with significant water stress and are exposed to heat waves. These operational risks, along with the emissions variability due to regional grid differences, underscore the need for sustainable and reliable future planning of data centers.
more »
« less
- Award ID(s):
- 2244715
- PAR ID:
- 10677136
- Publisher / Repository:
- IOP Science
- Date Published:
- Journal Name:
- Environmental Research Communications
- Volume:
- 7
- Issue:
- 11
- ISSN:
- 2515-7620
- Page Range / eLocation ID:
- 111005
- Subject(s) / Keyword(s):
- Associated Dataset(s):
- View Associated Dataset(s) >>
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Data centers' energy consumption is expected to rise significantly over the next five years due to the accelerated growth of AI and its computational demands. Simultaneously, initiatives are underway to mitigate the environmental impact of the energy usage by replacing brown energy sources (e.g., coal) with green energy sources (e.g., solar), resulting in a projected decrease in grid carbon intensity. Yet, the interplay between these two contrasting forces on data centers' carbon emissions — a function of both energy consumption and carbon intensity — has not received much attention. In this paper, we analyze the operational carbon emissions of data centers at this crossroads, by considering the increasing data center energy consumption and the decarbonization of the electricity grid. In particular, we integrate publicly available current and future energy projections, consider multiple future scenarios, and provide a 5-year projection of datacenter carbon emissions at the global, US, and state levels. Our analysis shows that over the next five years, the rate of data center demand growth will overshadow the rate of grid decarbonization, with global (resp. US) emissions projected to rise by 4.2× (resp. 4.1×) in the worst case by 2030. Moreover, we observe considerable regional differences within the US, where emissions in some states could increase by up to 3.4× by 2030.more » « less
-
Abstract The energy demands from data centers contribute greatly to water scarcity footprint and carbon emissions. Understanding the use of on-site renewable power generation is an important step to gain insight into making data centers more sustainable. This novel study examines the impact of on-site solar or wind energy on data center water scarcity usage effectiveness (WSUE) and carbon usage effectiveness (CUE) at a U.S. county scale for a given data center size, water consumption level, and energy efficiency. The analysis uncovers combinations of specific metrics associated with grid-based carbon emissions and water scarcity footprint that enable predictions of the improvements anticipated when implementing on-site solar or wind energy. The implementation of on-site renewables has the most benefit in reducing carbon footprint in areas with high existing grid-based emissions such as the western side of the Appalachian Mountains (e.g., central and eastern Kentucky). The largest benefit in reducing water scarcity footprint is generally seen in counties with low water scarcity compared to adjacent areas (e.g., northern California).more » « less
-
Data centers are critical to today’s digital economy, but are also among the largest industrial consumers of freshwater. Beyond the sheer volume of water use, the environmental impact of data center water consumption varies significantly across locations and seasons, depending on local and regional water stress. However, prior research has largely focused on reducing total water use, overlooking that the same unit of water can have drastically different environmental consequences depending on when and where it is consumed. In this paper, we introduce a stress-adjusted water framework that quantifies the true sustainability impact of data center water consumption by incorporating both spatial and temporal water stress. Using the AWARE-US model, we capture county-level monthly variations in water availability and extend this framework to account for the off-site water footprint of electricity generation. Based on this stress-aware accounting, we analyze stress-adjusted water-computing strategies spanning both the software and infrastructure layers. Specifically, we study workload scheduling policies that jointly optimize water and carbon efficiency, evaluate the potential of rainwater harvesting as a supplemental water source, and investigate the feasibility of dry cooling as a water-free alternative to evaporative cooling. Our evaluation across major U.S. data center markets shows that stress-aware workload scheduling can reduce stress-adjusted water consumption by up to 25% while preserving performance and balancing carbon emissions. We further show that rainwater harvesting can offset up to 100% of on-site cooling water in regions with sufficient precipitation, while offering diminishing returns in arid locations. Finally, our analysis of dry cooling reveals that its effectiveness depends critically on energy efficiency and off-site water stress, highlighting important trade-offs between water savings, energy use, and carbon emissions. Together, these results demonstrate that incorporating water stress as a first-class sustainability metric enables more informed and effective data center design and operationmore » « less
-
Immersion cooling has emerged as a promising solution for the escalating thermal management challenges in the contemporary and modern (next generation) data centers, where traditional air-cooling systems are increasingly inadequate due to rising power densities in microprocessors. The evolution of immersion cooling technologies, highlighting their benefits and the challenges associated with their implementation, is explored in this review. Two-phase microchannel cooling has often been cited as a highly efficient alternative, which can help achieve significant energy savings over air cooling. Subsequent studies have expanded on methods like refrigerant touch cooling, thermosiphon systems, and geothermal immersion cooling. All these strategies can help achieve enhanced energy efficiency, reduced operational costs, and improved Power Usage Effectiveness (PUE). Immersion cooling has been demonstrated to support denser CPU packaging and meet the demands of high-performance computing environments. Despite these advantages, challenges persist, including the need for specialized infrastructure, potential risks related to liquid handling, and integration with existing systems. Advances in environmentally friendly cooling fluids and optimized airflow management have begun to mitigate some of these issues. To fully realize the potential of immersion cooling, future research endeavors should focus on developing standardized protocols and best practices to facilitate its widespread adoption. Enhancing the compatibility of cooling fluids with a broader range of hardware components will be crucial, as will designing systems that are easier to integrate with existing data center infrastructure. Exploring hybrid cooling solutions that combine immersion cooling with other efficient methods could offer additional benefits. Further investigation into the long-term reliability, maintenance requirements, and environmental impacts of immersion-cooled systems is essential. Integrating immersion cooling with renewable energy sources and waste heat recovery systems could also enhance sustainability and operational efficiency (e.g., for thermal desalination and wood drying applications). The literature reports can be utilized to identify a clear trend toward adopting immersion cooling as a key strategy for improving energy efficiency and thermal management in data centers. Hence, ongoing research and development efforts need to be redirected to overcoming these remaining obstacles, thus paving the way for more energy efficient data center operations with reduced footprint for water and power consumption in the future; while also improving the sustainability, reliability, robustness, and resilience of these platforms.more » « less
An official website of the United States government