Recent advances in skin-interfaced wearable sweat sensors enable the noninvasive, real-time monitoring of biochemical signals associated with health and wellness. These wearable platforms leverage microfluidic channels, biochemical sensors, and flexible electronics to enable the continuous analysis of sweat-based biomarkers such as electrolytes, metabolites, and hormones. As this field continues to mature, the potential of low-cost, continuous personalized health monitoring enabled by such wearable sensors holds significant promise for addressing some of the formidable obstacles to delivering comprehensive medical care in under-resourced settings. This Perspective highlights the transformative potential of wearable sweat sensing for providing equitable access to cutting-edge healthcare diagnostics, especially in remote or geographically isolated areas. It examines the current understanding of sweat composition as well as recent innovations in microfluidic device architectures and sensing strategies by showcasing emerging applications and opportunities for innovation. It concludes with a discussion on expanding the utility of wearable sweat sensors for clinically relevant health applications and opportunities for enabling equitable access to innovation to address existing health disparities.
more »
« less
A bioinspired microfluidic wearable sensor for multiday sweat sampling, transport, and metabolic analysis
Wearable sweat sensors enable noninvasive real-time biochemical monitoring, holding immense potential for personalized health care applications. However, achieving prolonged and reliable sweat sampling, along with stable biochemical analysis, remains challenging due to inconsistent secretion, rapid evaporation, and the reliance on external stimulation. Here, we present BMS3, a bioinspired microfluidic wearable sweat sensor system designed for multiday continuous metabolic monitoring. BMS3integrates hierarchically graded microchannels and superhydrophobic-superhydrophilic Janus membranes, inspired by pitcher plant trichomes and lotus leaves to enable efficient low volume sweat collection, transport, and renewal. A miniaturized carbachol gel–based iontophoresis module autonomously induces localized sweat secretion. Furthermore, the microfluidic design sustains sweat sampling for over 2 days from a single iontophoresis session, eliminating the need for physical exertion. In vitro and in vivo studies in healthy participants and patients with gout demonstrate BMS3’s capability for continuous metabolic monitoring. By simultaneously tracking uric acid, xanthine, and alcohol levels, it effectively differentiates normal and pathological states while delivering timely therapeutic feedback.
more »
« less
- Award ID(s):
- 2145802
- PAR ID:
- 10679063
- Publisher / Repository:
- AAAS
- Date Published:
- Journal Name:
- Science Advances
- Volume:
- 11
- Issue:
- 33
- ISSN:
- 2375-2548
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Sweat has emerged as a promising biofluid for wearable health monitoring due to its ability to provide noninvasive and continuous access to a wide range of biomarkers. While advances in sensing materials and device integration have accelerated the field, measurement reliability is fundamentally governed by how sweat is induced, intercepted, transported, and refreshed at the skin–device interface. Outside of exercise or thermal stress, sweat secretion is often low, transient, and spatially heterogeneous, making sweat availability—not sensing chemistry—the primary constraint for continuous monitoring. This Review reframes sweat sampling as an integrated engineering pipeline spanning physiological induction, on-skin capture, directional transport, flow regulation, storage, and outlet-driven refreshment. We summarize sweat gland physiology and compositional dynamics that define biomarker accessibility, compare whole-body, localized thermal, and cholinergic induction strategies, and analyze modern microfluidic architectures designed to sustain temporal resolution under low and variable sweat flux. Particular emphasis is placed on system-level coupling between programmable induction and controlled fluid handling to enable quantitative and long-duration monitoring. By shifting focus from sensing chemistry alone to induction–sampling integration, we outline design principles required to make sweat a reliable and comparable biofluid for real-world wearable applications.more » « less
-
Abstract Although increasing efforts have been devoted to the development of non‐invasive wearable electrochemical sweat sensors for monitoring physiological and metabolic information, most of them still suffer from poor stability and specificity over time and fluctuating temperatures. This study reports the design and fabrication of a long‐term stable and highly sensitive flexible electrochemical sensor based on nanocomposite‐modified porous graphene by facile laser treatment for detecting biomarkers such as glucose in sweat. The laser‐reduced and patterned stable conductive nanocomposite on the porous graphene electrode provides the resulting glucose sensor with an excellent sensitivity of 1317.69 µA mm−1cm−2and an ultra‐low limit of detection of 0.079 µm. The sensor can also detect pH and exhibit extraordinary stability to maintain more than 91% sensitivity over 21 days in ambient conditions. Taken together with a temperature sensor based on the same material system, the dual glucose and pH sensor integrated with a flexible microfluidic sweat sampling network further results in accurate continuous on‐body glucose detection calibrated by the simultaneously measured pH and temperature. The low‐cost, highly sensitive, and long‐term stable platform could facilitate the early identification and continuous monitoring of different biomarkers for non‐invasive disease diagnosis and treatment evaluation.more » « less
-
Wearable sweat biosensors have shown great progress in noninvasive, in situ, and continuous health monitoring to demonstrate individuals’ physiological states. Advances in novel nanomaterials and fabrication methods promise to usher in a new era of wearable biosensors. Here, we introduce a threedimensional (3D)-printed flexible wearable health monitor fabricated through a unique one-step continuous manufacturing process with self-supporting microfluidic channels and novel single-atom catalyst-based bioassays for measuring the sweat rate and concentration of three biomarkers. Direct ink writing is adapted to print the microfluidic device with self-supporting structures to harvest human sweat, which eliminates the need for removing sacrificial supporting materials and addresses the contamination and sweat evaporation issues associated with traditional sampling methods. Additionally, the pick-and-place strategy is employed during the printing process to accurately integrate the bioassays, improving manufacturing efficiency. A single-atom catalyst is developed and utilized in colorimetric bioassays to improve sensitivity and accuracy. A feasibility study on human skin successfully demonstrates the functionality and reliability of our health monitor, generating reliable and quantitative in situ results of sweat rate, glucose, lactate, and uric acid concentrations during physical exercise.more » « less
-
Managing stress is essential for mental and physical health, yet current methods rely on subjective self-assessments or indirect physiological measurements, often lacking accuracy. Existing wearable sensors primarily target a single stress hormone, cortisol, using single-point measurements that fail to capture real-time changes and distinguish between acute and chronic stress. To address this, we present Stressomic, a wearable multiplexed microfluidic biosensor for noninvasive monitoring of cortisol, epinephrine, and norepinephrine in sweat. Stressomic integrates iontophoresis-driven sweat extraction with bursting valve-regulated microfluidic channels for continuous sampling and analysis. Gold nanodendrite–decorated laser-engraved graphene electrodes achieve picomolar-level sensitivity, enabling simultaneous detection of multiple stress hormones. Electrochemical assays and human studies demonstrate that Stressomic reliably tracks hormone fluctuations in response to physical, psychological, and pharmacological stressors. Distinct temporal patterns reveal the dynamic interplay between the hypothalamic-pituitary-adrenal axis and the sympathetic nervous system. This platform enables continuous, multiplexed stress profiling, offering opportunities for early detection of maladaptive responses, personalized stress management, and deeper insights into stress biology.more » « less
An official website of the United States government

