Abstract The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real‐time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost‐effective method to prepare high‐quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)‐facets. The as‐fabricated TiO2film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin‐interfaced patch with microfluidic sampling and wireless transmission units for real‐time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
more »
« less
Structure and Electrochemical Properties of ReS 2 ‐LaFeO 3 Nanocomposite for Dopamine Sensing
Abstract This study presents the first investigation of a ReS2‐LaFeO3nanocomposite for the electrochemical detection of dopamine (DA). ReS2‐LaFeO3nanocomposites (5%, 10%, and 20% ReS2by weight) are synthesized hydrothermally on porous LaFeO3nanofibers prepared via electrospinning and annealing. The resulting materials are thoroughly characterized using spectroscopic and microscopic techniques. Electrochemical DA detection (0.02 µm– 1 mm) is performed using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA). The 10 wt.% ReS2‐LaFeO3nanocomposite demonstrates exceptional performance, achieving a high sensitivity of 0.191 µA µM⁻¹ cm⁻2. In comparison, LaFeO3, 5 wt.% ReS2‐LaFeO3, 20 wt.% ReS2‐LaFeO3, and pristine ReS2exhibit limits of detection (LODs) of 281, 357,187, and 120 µm, with corresponding sensitivities of 0.191, 0.156, 0.181, 0.183 µA µM⁻¹ cm⁻2, respectively. The representative 10 wt.% ReS2‐LaFeO3nanocomposite exhibits good selectivity and detection performance, as confirmed by tests with 1 mmconcentrations of common analytes in biological relevant chemicals such as uric acid (UA), sodium chloride (NaCl), hydrogen peroxide (H2O2), and ascorbic acid (AA). Furthermore, it shows varying response toward other neurotransmitters like epinephrine (EP) ad norepinephrine (NEP). The results of this investigation show that ReS2decoration on LaFeO3enhances the nanocomposite's physical, chemical, and electrical properties, leading to improved charge separation and reliable DA sensing in complex biological samples.
more »
« less
- Award ID(s):
- 2122044
- PAR ID:
- 10680448
- Publisher / Repository:
- Wiley
- Date Published:
- Journal Name:
- Advanced Sensor Research
- Volume:
- 4
- Issue:
- 9
- ISSN:
- 2751-1219
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Although increasing efforts have been devoted to the development of non‐invasive wearable electrochemical sweat sensors for monitoring physiological and metabolic information, most of them still suffer from poor stability and specificity over time and fluctuating temperatures. This study reports the design and fabrication of a long‐term stable and highly sensitive flexible electrochemical sensor based on nanocomposite‐modified porous graphene by facile laser treatment for detecting biomarkers such as glucose in sweat. The laser‐reduced and patterned stable conductive nanocomposite on the porous graphene electrode provides the resulting glucose sensor with an excellent sensitivity of 1317.69 µA mm−1cm−2and an ultra‐low limit of detection of 0.079 µm. The sensor can also detect pH and exhibit extraordinary stability to maintain more than 91% sensitivity over 21 days in ambient conditions. Taken together with a temperature sensor based on the same material system, the dual glucose and pH sensor integrated with a flexible microfluidic sweat sampling network further results in accurate continuous on‐body glucose detection calibrated by the simultaneously measured pH and temperature. The low‐cost, highly sensitive, and long‐term stable platform could facilitate the early identification and continuous monitoring of different biomarkers for non‐invasive disease diagnosis and treatment evaluation.more » « less
-
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.more » « less
-
Abstract L‐cysteine plays a significant role in numerous physiological processes in the human body health, and monitoring its level has important clinical implications. However, L‐cysteine tests are limited to invasive blood drawing and a time‐consuming laboratory process, which also fails to give real‐time and continuous results. This study introduces a flexible electrochemical sensor based on a self‐assembled monolayer (SAM) of 3‐mercaptopropyltrimethoxysilane (MPTS) molecular receptor and catalytic titanium oxide‐modified carbon cloth (MPTS/TiO2/CC). The MPTS and TiO2modification serve as the artificial antibody through thiol interactions and the charge transfer layer, respectively, which is further confirmed by density function theory (DFT) calculations. The flexible L‐cysteine sensor based on MPTS/TiO2/CC shows a wide linear range of up to 500 µmand an ultra‐low limit of detection of 0.046 µm. A sweat patch consisting of an electrochemical sensing unit, a laser‐fabricated microfluidic channel, and a miniaturized electrochemical workstation affords real‐time monitoring of L‐cysteine detection in dynamic environments and reveals the strong correlation between sweat and blood L‐cysteine concentrations. The introduction of molecular receptors and band alignment may offer a general way of designing sensitive, specific electrochemical sensors for point‐of‐care diagnosis.more » « less
-
The simple synthesis of a Ni–TiO2nanocomposite supported on Vulcan carbon (XC–72 R) for the electrooxidation reaction of glucose is reported. Four transition metal weight ratios were synthesized and characterized. Cyclic voltammetry studies in 0.1 M NaOH demonstrate that the four metal catalysts can effectively oxidize 1 mM glucose, with the 3:1 (60%) Ni to Ti nanocomposite yielding the highest current. The 60% Ni–TiO2/XC72R catalyst was used to construct an enzyme–less, chronoamperometric sensor for glucose detection in an alkaline medium. Using 50μM aliquots of glucose at a potential of +0.7 V (vs Hg/HgO), the sensor responded rapidly (<3 s), provided a sensitivity of 3300μA mM−1cm−2, detection limits of 144 nM (Signal/Noise = 3), and excellent selectivity and reproducibility. The glucose aliquot concentrations were then increased to 1 mM to mimic physiological blood conditions of 1–20 mM. At a potential of +0.7 V (vs Hg/HgO), the sensor continued to respond rapidly (<1 s), showed a sensitivity of 273.7μA mM−1cm−2, detection limits of 3.13μM (S/N = 3), and excellent selectivity and reproducibility. The catalyst also exhibited an ideal anti–poisoning capability to free chloride ions and negligible signals towards other interfering species.more » « less
An official website of the United States government