Images document scientific discoveries and are prevalent in modern biomedical research. Microscopy imaging in particular is currently undergoing rapid technological advancements. However, for scientists wishing to publish obtained images and image-analysis results, there are currently no unified guidelines for best practices. Consequently, microscopy images and image data in publications may be unclear or difficult to interpret. Here, we present community-developed checklists for preparing light microscopy images and describing image analyses for publications. These checklists offer authors, readers and publishers key recommendations for image formatting and annotation, color selection, data availability and reporting image-analysis workflows. The goal of our guidelines is to increase the clarity and reproducibility of image figures and thereby to heighten the quality and explanatory power of microscopy data.
more »
« less
Best practices in plant fluorescence imaging and reporting: A primer
Abstract Microscopy is a fundamental approach for plant cell and developmental biology as well as an essential tool for mechanistic studies in plant research. However, setting up a new microscopy-based experiment can be challenging, especially for beginner users, when implementing new imaging workflows or when working in an imaging facility where staff may not have extensive experience with plant samples. The basic principles of optics, chemistry, imaging, and data handling are shared among all cell types. However, unique challenges are faced when imaging plant specimens due to their waxy cuticles, strong/broad spectrum autofluorescence, recalcitrant cell walls, and air spaces that impede fixation or live imaging, impacting sample preparation and image quality. As expert plant microscopists, we share our collective experience on best practices to improve the quality of published microscopy results and promote transparency, reproducibility, and data reuse for meta-analyses. We offer plant-specific advice and examples for microscope users at all stages of fluorescence microscopy workflows, from experimental design through sample preparation, image acquisition, processing, and analyses, to image display and methods reporting in manuscripts. We also present standards for methods reporting that will be valuable to all users and offer tools to improve reproducibility and data sharing.
more »
« less
- Award ID(s):
- 2420360
- PAR ID:
- 10681380
- Publisher / Repository:
- The Plant Cell
- Date Published:
- Journal Name:
- The Plant Cell
- Volume:
- 37
- Issue:
- 7
- ISSN:
- 1040-4651
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
ABSTRACT Sample preparation is an important first step to obtain high quality mass spectrometry imaging (MSI) data. Preparing plant tissues is especially challenging for MSI of thin tissues along the lateral dimensions. The unique challenges involved with plant tissues, such as fragile cell walls, hydrophobic barriers, and specific tissue structures, often lead to inefficiency and difficulties in sample preparation. Imprinting plant tissues onto porous polytetrafluoroethylene (pPTFE) sheet has been widely used to extract internal metabolites in leaves and petals while keeping spatial resolution for MSI. However, pressure applications were typically made manually using a vise or pliers leading to low reproducibility and resolution in MS images. In this study, we introduce a home‐built pneumatic press (PNP) that has been designed to precisely control the pressure application parameters during imprinting. To evaluate the performance of the new device,Lemna minorfronds,Arabidopsis thaliana, andBacopa monnierileaves were imprinted onto the pPTFE with PNP, vise, or pliers, and matrix‐assisted laser desorption/ionization (MALDI) MSI was obtained on the imprints. The PNP showed dramatic improvements in reproducibility and image quality compared to manual pressure application tools.more » « less
-
Abstract BackgroundTo address the limitations of large-scale high quality microscopy image acquisition, PSSR (Point-Scanning Super-Resolution) was introduced to enhance easily acquired low quality microscopy data to a higher quality using deep learning-based methods. However, while PSSR was released as open-source, it was difficult for users to implement into their workflows due to an outdated codebase, limiting its usage by prospective users. Additionally, while the data enhancements provided by PSSR were significant, there was still potential for further improvement. MethodsTo overcome this, we introduce PSSR2, a redesigned implementation of PSSR workflows and methods built to put state-of-the-art technology into the hands of the general microscopy and biology research community. PSSR2 enables user-friendly implementation of super-resolution workflows for simultaneous super-resolution and denoising of undersampled microscopy data, especially through its integrated Command Line Interface and Napari plugin. PSSR2 improves and expands upon previously established PSSR algorithms, mainly through improvements in the semi-synthetic data generation (“crappification”) and training processes. ResultsIn benchmarking PSSR2 on a test dataset of paired high and low resolution electron microscopy images, PSSR2 super-resolves high-resolution images from low-resolution images to a significantly higher accuracy than PSSR. The super-resolved images are also more visually representative of real-world high-resolution images. DiscussionThe improvements in PSSR2, in providing higher quality images, should improve the performance of downstream analyses. We note that for accurate super-resolution, PSSR2 models should only be applied to super-resolve data sufficiently similar to training data and should be validated against real-world ground truth data.more » « less
-
Abstract IntroductionTraction force microscopy (TFM) is a widely used technique to measure cell contractility on compliant substrates that mimic the stiffness of human tissues. For every step in a TFM workflow, users make choices which impact the quantitative results, yet many times the rationales and consequences for making these decisions are unclear. We have found few papers which show the complete experimental and mathematical steps of TFM, thus obfuscating the full effects of these decisions on the final output. MethodsTherefore, we present this “Field Guide” with the goal to explain the mathematical basis of common TFM methods to practitioners in an accessible way. We specifically focus on how errors propagate in TFM workflows given specific experimental design and analytical choices. ResultsWe cover important assumptions and considerations in TFM substrate manufacturing, substrate mechanical properties, imaging techniques, image processing methods, approaches and parameters used in calculating traction stress, and data-reporting strategies. ConclusionsBy presenting a conceptual review and analysis of TFM-focused research articles published over the last two decades, we provide researchers in the field with a better understanding of their options to make more informed choices when creating TFM workflows depending on the type of cell being studied. With this review, we aim to empower experimentalists to quantify cell contractility with confidence.more » « less
-
BackgroundWe performed a systematic review that identified at least 9,000 scientific papers on PubMed that include immunofluorescent images of cells from the central nervous system (CNS). These CNS papers contain tens of thousands of immunofluorescent neural images supporting the findings of over 50,000 associated researchers. While many existing reviews discuss different aspects of immunofluorescent microscopy, such as image acquisition and staining protocols, few papers discuss immunofluorescent imaging from an image-processing perspective. We analyzed the literature to determine the image processing methods that were commonly published alongside the associated CNS cell, microscopy technique, and animal model, and highlight gaps in image processing documentation and reporting in the CNS research field. MethodsWe completed a comprehensive search of PubMed publications using Medical Subject Headings (MeSH) terms and other general search terms for CNS cells and common fluorescent microscopy techniques. Publications were found on PubMed using a combination of column description terms and row description terms. We manually tagged the comma-separated values file (CSV) metadata of each publication with the following categories: animal or cell model, quantified features, threshold techniques, segmentation techniques, and image processing software. ResultsOf the almost 9,000 immunofluorescent imaging papers identified in our search, only 856 explicitly include image processing information. Moreover, hundreds of the 856 papers are missing thresholding, segmentation, and morphological feature details necessary for explainable, unbiased, and reproducible results. In our assessment of the literature, we visualized current image processing practices, compiled the image processing options from the top twelve software programs, and designed a road map to enhance image processing. We determined that thresholding and segmentation methods were often left out of publications and underreported or underutilized for quantifying CNS cell research. DiscussionLess than 10% of papers with immunofluorescent images include image processing in their methods. A few authors are implementing advanced methods in image analysis to quantify over 40 different CNS cell features, which can provide quantitative insights in CNS cell features that will advance CNS research. However, our review puts forward that image analysis methods will remain limited in rigor and reproducibility without more rigorous and detailed reporting of image processing methods. ConclusionImage processing is a critical part of CNS research that must be improved to increase scientific insight, explainability, reproducibility, and rigor.more » « less
An official website of the United States government

