Abstract The energy demands from data centers contribute greatly to water scarcity footprint and carbon emissions. Understanding the use of on-site renewable power generation is an important step to gain insight into making data centers more sustainable. This novel study examines the impact of on-site solar or wind energy on data center water scarcity usage effectiveness (WSUE) and carbon usage effectiveness (CUE) at a U.S. county scale for a given data center size, water consumption level, and energy efficiency. The analysis uncovers combinations of specific metrics associated with grid-based carbon emissions and water scarcity footprint that enable predictions of the improvements anticipated when implementing on-site solar or wind energy. The implementation of on-site renewables has the most benefit in reducing carbon footprint in areas with high existing grid-based emissions such as the western side of the Appalachian Mountains (e.g., central and eastern Kentucky). The largest benefit in reducing water scarcity footprint is generally seen in counties with low water scarcity compared to adjacent areas (e.g., northern California).
more »
« less
Data Centers Carbon Emissions at Crossroads: An Empirical Study
Data centers' energy consumption is expected to rise significantly over the next five years due to the accelerated growth of AI and its computational demands. Simultaneously, initiatives are underway to mitigate the environmental impact of the energy usage by replacing brown energy sources (e.g., coal) with green energy sources (e.g., solar), resulting in a projected decrease in grid carbon intensity. Yet, the interplay between these two contrasting forces on data centers' carbon emissions — a function of both energy consumption and carbon intensity — has not received much attention. In this paper, we analyze the operational carbon emissions of data centers at this crossroads, by considering the increasing data center energy consumption and the decarbonization of the electricity grid. In particular, we integrate publicly available current and future energy projections, consider multiple future scenarios, and provide a 5-year projection of datacenter carbon emissions at the global, US, and state levels. Our analysis shows that over the next five years, the rate of data center demand growth will overshadow the rate of grid decarbonization, with global (resp. US) emissions projected to rise by 4.2× (resp. 4.1×) in the worst case by 2030. Moreover, we observe considerable regional differences within the US, where emissions in some states could increase by up to 3.4× by 2030.
more »
« less
- Award ID(s):
- 2325956
- PAR ID:
- 10682138
- Publisher / Repository:
- ACM
- Date Published:
- Journal Name:
- ACM SIGEnergy Energy Informatics Review
- Volume:
- 5
- Issue:
- 2
- ISSN:
- 2770-5331
- Page Range / eLocation ID:
- 48 to 55
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract We present a typology of 2205 U.S. transit systems, derived from 167 operational indicators in the National Transit Database, to reveal distinct patterns. Using kernel principal component analysis and Gaussian mixture modeling, we identify five distinct transit system types:Metro Bus–Rail,Mid-Sized Urban,Hybrid Multimodal,Urban Specialized, andDiverse Operations. We also discover a gap in diesel consumption reporting (76% of systems), which are predominantly of theMid-Sized Urbantype. To bridge this critical data gap, we apply extreme gradient boosting to predict the diesel consumption for 1674 underreported systems. We then estimate lifecycle emissions, accounting for regional grid carbon intensity. The result highlights significant variability in diesel consumption and emissions across transit types, withMetro Bus–Railsystems contributing the highest emissions. To evaluate decarbonization potential, we simulate fleet electrification and grid decarbonization. Our scenario analyses indicate that up to 82% of 10.27 MMTCO2e diesel-based transit emissions can be eliminated through fleet electrification, with further grid decarbonization eliminating the remainder. These findings provide actionable insights for policymakers to prioritize electrification, optimize resource allocation, and support sustainable transit strategies in the U.S.more » « less
-
Fired clay bricks (FCBs) are a dominant building material globally due to their low cost and simplicity of production, especially in low- and middle-income countries. With a projected rising housing demand, commensurate growth in brick demand is anticipated, the production of which could result in significant greenhouse gas (GHG) emissions. Robust models are needed to estimate brick demand and emissions to systematically address decarbonization pathways. Few sources report production values; hence, we present two novel proxy models: (i) a consumption prediction model, relying on country-specific clay extraction data, dynamic building stock modeling, and average material intensity use allowing for projections to 2050; and (ii) a GHG emissions model, using literature-based data and production technology-specific inputs. Based on these models, the current global FCB consumption is estimated as 2.18 Gt annually, resulting in approximately 500 million tCO2e (1% of current global GHG emissions). If unaddressed, this fraction could increase to 3.5–5% in 2050 considering a moderate SSP 2-4.5 climate change mitigation scenario. Consequently, we explored three potential decarbonization pathways: (i) improving energy efficiency; (ii) shifting production to best practices; and (iii) replacing half of FCB demand with hollow concrete blocks, resulting in 27%, 49%, and 51% reduction in GHG emissions, respectively.more » « less
-
Heating buildings using fossil fuels such as natural gas, propane and oil makes up a significant proportion of the aggregate carbon emissions every year. Because of this, there is a strong interest in decarbonizing residential heating systems using new technologies such as electric heat pumps. In this paper, we conduct a data-driven optimization study to analyze the potential of replacing gas heating with electric heat pumps to reduce CO 2 emission in a city-wide distribution grid. We conduct an in-depth analysis of gas consumption in the city and the resulting carbon emissions. We then present a flexible multi-objective optimization (MOO) framework that optimizes carbon emission reduction while also maximizing other aspects of the energy transition such as carbon-efficiency, and minimizing energy inefficiency in buildings. Our results show that replacing gas with electric heat pumps has the potential to cut carbon emissions by up to 81%. We also show that optimizing for other aspects such as carbon-efficiency and energy inefficiency introduces tradeoffs with carbon emission reduction that must be considered during transition. Finally, we present a detailed analysis of the implication of proposed transition strategies on the household energy consumption and utility bills, electric grid upgrades, and decarbonization policies. We compute the additional energy demand from electric heat pumps at the household as well as the transformer level and discuss how our results can inform decarbonization policies at city scale.more » « less
-
Content Delivery Networks (CDNs) are Internet-scale systems that deliver streaming and web content to users from many geographically distributed edge data centers. Since large CDNs can comprise hundreds of thousands of servers deployed in thousands of global data centers, they can consume a large amount of energy for their operations and thus are responsible for large amounts of Green House Gas (GHG) emissions. As these networks scale to cope with increased demand for bandwidth-intensive content, their emissions are expected to rise further, making sustainable design and operation an important goal for the future. Since different geographic regions vary in the carbon intensity and cost of their electricity supply, in this paper, we consider spatial shifting as a key technique to jointly optimize the carbon emissions and energy costs of a CDN. We present two forms of shifting: spatial load shifting, which operates within the time scale of minutes, and VM capacity shifting, which operates at a coarse time scale of days or weeks. The proposed techniques jointly reduce carbon and electricity costs while considering the performance impact of increased request latency from such optimizations. Using real-world traces from a large CDN and carbon intensity and energy prices data from electric grids in different regions, we show that increasing the latency by 60ms can reduce carbon emissions by up to 35.5%, 78.6%, and 61.7% across the US, Europe, and worldwide, respectively. In addition, we show that capacity shifting can increase carbon savings by up to 61.2%. Finally, we analyze the benefits of spatial shifting and show that it increases carbon savings from added solar energy by 68% and 130% in the US and Europe, respectively.more » « less
An official website of the United States government