Attention:NSF PAR will be unavailable due to scheduled facility maintenance July 10th, 5 PM EDT through July 13th. We apologize for any inconvenience.


This content will become publicly available on April 28, 2027

Title: Physical Damage-Measured Response Correlation for Nonstructural Components Tested under Multi-hazard (Earthquake and Fire) Demands in the CFS10 Building
This paper is the second of a set presented within the session: Findings from the CFS10 MultiHazard Test Program. The emphasis within this article is to highlight correlations between physical damage to nonstructural components and systems with measured response during a suite of 18 earthquake tests and two subsequent fire tests. This damage was documented within a 10story cold-formed steel-framed building test specimen outfitted with various nonstructural components, including suspended ceilings, architectural finishes, a resilient stair system, windows and doors, pressurized fire sprinkler and gas piping systems, and roof-mounted mechanical equipment. The test building and multi-hazard protocol are described in the session companion paper. This paper provides test observations correlated with measured engineering demand parameters such as floor acceleration, building inter-story drift or peak local temperature responses and offers related literature emerging from the project. Damage data and functionality checks will support development of fragility functions for these nonstructural systems for use in recoverybased frameworks.  more » « less
Award ID(s):
1663569
PAR ID:
10684977
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ;
Publisher / Repository:
SEI/Structures Congress
Date Published:
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. A 10-story cold-formed steel (CFS) building, referred to as CFS10, was constructed and tested at the 6-DOF Large High Performance Outdoor Shake Table (LHPOST6) at UC San Diego (NHERI@UC San Diego). This unique building specimen was designed beyond current seismic provisions, notably exceeding the height limit as prescribed in ASCE 7-22 and employing shear wall detailing that is currently not available in the most recent AISI S400-20 design standard. The test specimen was additionally outfitted with a wide range of nonstructural components and systems, designed and installed at various levels of the building, to understand the evolution of damage in a real building system under multi-directional seismic excitation. Limiting damage to nonstructural components plays a key role in maintaining or regaining post- earthquake building functionality. To this end, an essential aspect of the test program is to improve upon the key gaps in the state of knowledge of nonstructural seismic performance and functional recovery of buildings, especially in CFS-framed buildings. This paper presents preliminary observations of damage and functionality correlated with the measured seismic response of select nonstructural systems, namely suspended ceilings, and pressurized fire sprinkler and gas piping systems, focusing on their performance and interactions at the ceiling of Story 10 in the building. Observations related to damage and functionality can inform the development of fragility functions for these nonstructural systems and support improved functional recovery design provisions. 
    more » « less
  2. The objective of this paper is to investigate the post-earthquake thermal-mechanical response of cold-formed steel (CFS) members. A 10-story cold-formed steel building (CFS-NHERI) will undergo seismic tests, followed by post-earthquake live fire tests. To support the fire test setup, computational models are developed to simulate the impact of varying post-earthquake damage levels on the fire response of the structure. As a panelized system, damage to different finish and nonstructural systems significantly affects the thermal behavior and load-bearing capacity of the CFS components. The computational models integrate the modeling capability in CUFSM and SAFIR for the elastic buckling, heat transfer, and transient structural analysis under fire. A parametric analysis considering different seismic damage levels is conducted to study the buckling and strength behavior of the CFS members under fire-induced nonuniform temperature fields. These pre-test models inform the duration and severity of the fire tests to maintain structural stability while achieving substantial thermal loading on the CFS load-bearing system. They also provide guidance for the sensor layout plan for the fire tests. This study advances methods for fire resilience of thin-walled CFS structures under multi-hazard scenarios. 
    more » « less
  3. This paper is the first in a pair presented within the session: Findings from the CFS10 Multi-Hazard Test Program. The emphasis within this article is to, in brevity, describe the scope of a landmark full-scale 10-story cold-formed steel (CFS) framed building tested under multi-hazard (earthquake and fire) scenarios at the UC San Diego 6-DOF Large High-Performance Outdoor Shake Table (LHPOST6). Coined CFS10, this unique building specimen is designed beyond current code height limits, adopting advances in cold-formed steel shear wall detailing, varied construction modalities, and enriched with nonstructural components and systems. The landmark CFS10 building specimen was subjected to extreme multi-hazard (earthquake and fire) loading conditions. This paper sets the framework for presentations to be shared at the Congress, while also aiding in ongoing documentation of findings from the program. 
    more » « less
  4. A series of shake table tests were recently conducted on full-scale 10-story and 6-story mass timber buildings at the 6-DOF Large High-Performance Outdoor Shaking Table facility at the University of California San Diego. Stairs, providing the primary egress in and out of a building during and after an earthquake event, were incorporated in each of these building test programs. To ensure they support the immediate recovery of building function, a variety of drift-release details were incorporated. Previous earthquake events and experimental studies have shown that stairs are among the most drift-sensitive nonstructural systems and are prone to damage, therefore relieving interstory drifts is paramount to improving their performance. To this end, the designed drift-release connections within the stairs considered the test buildings response during earthquake motions scaled at various hazard levels with expected minor and repairable damage under large earthquake loading. This paper provides an overview of the shake table test programs from the perspective of the design and performance of resilient steel stairs. 
    more » « less
  5. To advance understanding of the multihazard performance of midrise cold-formed steel (CFS) construction, a unique multidisciplinary experimental program was conducted on the Large High-Performance Outdoor Shake Table (LHPOST) at the University of California, San Diego (UCSD). The centerpiece of this project involved earthquake and live fire testing of a full-scale 6-story CFS wall braced building. Initially, the building was subjected to seven earthquake tests of increasing motion intensity, sequentially targeting service, design, and maximum credible earthquake (MCE) demands. Subsequently, live fire tests were conducted on the earthquake-damaged building at two select floors. Finally, for the first time, the test building was subjected to two postfire earthquake tests, including a low-amplitude aftershock and an extreme near-fault target MCE-scaled motion. In addition, low-amplitude white noise and ambient vibration data were collected during construction and seismic testing phases to support identification of the dynamic state of the building system. This paper offers an overview of this unique multihazard test program and presents the system-level structural responses and physical damage features of the test building throughout the earthquake-fire-earthquake test phases, whereas the component-level seismic behavior of the shear walls and seismic design implications of CFS-framed building systems are discussed in a companion paper. 
    more » « less