During extreme events such as earthquakes, stairs are the primary means of egress in and out of buildings. Therefore, understanding the seismic response of this non-structural system is essential. Past earthquake events have shown that stairs with a flight to landing fixed connection are prone to damage due to the large interstory drift demand they are subjected to. To address this, resilient stair systems with drift-compatible connections have been proposed. These stair systems include stairs with fixed-free connections, sliding-slotted connections, and related drift-compatible detailing. Despite the availability of such details in design practice, they have yet to be implemented into full-scale, multi-floor building test programs. To conduct a system-level experimental study using true-to-field boundary conditions of these stair systems, several stair configurations are planned for integration within the NHERI TallWood 10-story mass timber building test program. The building is currently under construction at the UC San Diego 6-DOF Large High-Performance Outdoor Shake Table (LHPOST6). To facilitate pre-test investigation of the installed stair systems a comprehensive finite element model of stairs with various boundary conditions has been proposed and validated via comparison with experimental data available on like-detailed single-story specimens tested at the University of Nevada, Reno (UNR). The proposed modelling approach was used to develop the finite element model of a single-story, scissor-type, stair system with drift-compatible connections to be implemented in the NHERI TallWood building. This paper provides an overview, and pre-test numerical evaluation of the planned stair testing program within the mass timber shake table testing effort.
more »
« less
This content will become publicly available on March 10, 2027
Influence of Stair System Flexibility on Building Vibration Period: Insights from Full-Scale Building Shake Table Tests at Low-Amplitude Excitation
Stair systems, which provide the primary means of egress in and out of a building during and after an earthquake, play a critical role in seismic resiliency. Often, these systems are detailed with fixed flight-tolanding connections. However, previous experimental studies and field reconnaissance have shown that such configurations are prone to severe damage. To mitigate this damage to both the stair systems and the supporting structural members, as well as to avoid the ensuing potential to stiffen the lateral force resisting system of the building, stair connections are often detailed to release drift demands. Referred to as driftrelease, these approaches generally focus on releasing inter-story drift at the flight-to-landing connections. Findings from a recent shake table test of a 10-story prefabricated stair system within a mass timber building showed that stair systems with drift-release connections result in a seismically resilient egress solution. However, due to the free movement of stair flights, handrail connections received damage at multiple levels. In a complementary follow-on study, a 9-story stair system with refined connection details was integrated into a 10-story cold-formed steel (CFS10) building recently tested at NHERI@UC San Diego. Numerical analyses have indicated that stair systems with fixed flight-to-landing connections can influence the dynamic characteristics of the supporting structure due to strut action. As such, stairs in the CFS10 building system were designed to allow for easy modification between fixed and drift-release connections by installing or removing locking bolts at the flight to mid-landing interfaces. In the CFS10 building, white noise tests were conducted in each orthogonal direction under two configurations: first, with the stair connections fixed, and then with the locking bolts removed. This study aims to determine the impact of stair connection detailing on the modal characteristics of the building. In addition, complementary numerical simulations were carried out for both fixed and drift-release stair configurations. Based on both experimental and numerical studies, it is found that, under low-amplitude excitation, the impact of stair flexibility on the building vibration period is not significant because the drift-release connection is not appreciably engaged under small lateral loading. However, the impact of stair strut action under large-amplitude excitation still needs to be investigated.
more »
« less
- Award ID(s):
- 1663569
- PAR ID:
- 10684980
- Publisher / Repository:
- Sixth International Workshop on the Seismic Performance of Non-Structural Elements (SPONSE 2026)
- Date Published:
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Advancing the seismic resilience of building systems is an active area of research in earthquake engineering. Ensuring safe egress in and out of buildings during extreme events, such as an earthquake, is essential to supporting this effort. To this end, understanding the seismic response of stairs facilitates the robust design of egress systems to ensure they can remain operable after an earthquake. From prior earthquake events and physical experiments, it is understood that stairs with a flight to landing fixed connection at multiple levels within a building are prone to damage. In addition, the stair system with flight to landing fixed attachments may affect the dynamic behavior of the building. To accommodate seismic inter‐story drifts, a kinematically free connection between the stairs and landing has been proposed. Herein this connection is referred to as adrift‐compatiblestair connection. To investigate and aid in the design of such a connection, a unique set of shake table experiments were conducted at the University of Nevada, Reno. In this paper, an overview of these tests is presented, and a high‐fidelity finite element model of the tested stair system is used to predict the responses measured during these experiments. Developed in Abaqus, the robustness of the modeled stair unit is investigated considering a variety of contrasting connections, namely, drift‐compatible connections, fixed ends and one end fixed and the other free. Results from these numerical simulations offer guidance towards development of simplified models of multi‐level stair subsystems. Such models are needed when investigating seismic resilience of building systems across a wider range of hazard levels. Furthermore, best practices observed utilizing the models developed and evaluated herein against experimental data will be useful for subsequent analysis of larger stair tower models, such as the 10‐story stair system implemented in the NHERI Tall Wood mass timber building with post‐tensioned rocking walls, conducted in 2023 at the UC San Diego Large High‐Performance Outdoor Shake Table.more » « less
-
This paper is the second of a set presented within the session: Findings from the CFS10 MultiHazard Test Program. The emphasis within this article is to highlight correlations between physical damage to nonstructural components and systems with measured response during a suite of 18 earthquake tests and two subsequent fire tests. This damage was documented within a 10story cold-formed steel-framed building test specimen outfitted with various nonstructural components, including suspended ceilings, architectural finishes, a resilient stair system, windows and doors, pressurized fire sprinkler and gas piping systems, and roof-mounted mechanical equipment. The test building and multi-hazard protocol are described in the session companion paper. This paper provides test observations correlated with measured engineering demand parameters such as floor acceleration, building inter-story drift or peak local temperature responses and offers related literature emerging from the project. Damage data and functionality checks will support development of fragility functions for these nonstructural systems for use in recoverybased frameworks.more » « less
-
A series of shake table tests were recently conducted on full-scale 10-story and 6-story mass timber buildings at the 6-DOF Large High-Performance Outdoor Shaking Table facility at the University of California San Diego. Stairs, providing the primary egress in and out of a building during and after an earthquake event, were incorporated in each of these building test programs. To ensure they support the immediate recovery of building function, a variety of drift-release details were incorporated. Previous earthquake events and experimental studies have shown that stairs are among the most drift-sensitive nonstructural systems and are prone to damage, therefore relieving interstory drifts is paramount to improving their performance. To this end, the designed drift-release connections within the stairs considered the test buildings response during earthquake motions scaled at various hazard levels with expected minor and repairable damage under large earthquake loading. This paper provides an overview of the shake table test programs from the perspective of the design and performance of resilient steel stairs.more » « less
-
As a capstone to the multi-university-industry collaborative CFS-NHERI project, a full-scale 10-story building is constructed and tested under earthquake and live-fire scenarios at the NHERI 6-DOF Large High Performance Outdoor Shake Table (LHPOST6) facility. Coined CFS10, the building specimen is designed with a height of 31.6 m (103 ft 9 in), exceeding the height limitation of 19.8 m (65 ft) set by the current ASCE 7-22 design standard. The design also advances lateral force resisting system (LFRS) details to provide for the increases in seismic shear and overturning moment demands associated with increases in building height. Data generated from this unique experimental program will shed light on the impact of architectural exterior and interior finishes, non-designated systems, such as gravity walls or window/door framing, that are along the same architectural line of the CFS-framed shear wall system. Another key factor, higher mode effects, which can significantly influence the structural and nonstructural seismic response of tall buildings, is studied for the first time for such repetitively framed structures. Finally, the test building integrates conventional stick-framing, panelized (2D), and volumetric (3D) modular construction within one building specimen, allowing a unique opportunity to document and compare the efficiency of each construction method, and any differences in structural performance. The floor and roof diaphragm are also designed to embrace a modular stair system within the floor plan of the building. The seismically resilient stairs will provide safe egress/ingress to the building through the use of a variety of drift-compatible details, including following design and MCE level earthquake tests. This experimental program will provide vital full-scale system-level benchmark test data for a state-of-the-art CFS building under multidirectional seismic input. Furthermore, it will advance knowledge of the post-earthquake fire performance of mid-rise CFS construction, by incorporating a live fire test sequence following seismic test phase completion.more » « less