Additive manufacturing (AM) of polyetheretherketone (PEEK) offers a promising route for producing lightweight, biocompatible, and patient-specific medical implants with complex geometries. This study investigates and optimizes fused deposition modeling (FDM) parameters for fabricating small-scale PEEK medical components with improved dimensional accuracy and surface quality. PEEK’s high processing temperature and thermal contraction make precision printing of fine features challenging. A Taguchi design of experiments (L9 orthogonal array) was employed to assess the effects of nozzle temperature, layer height, printing speed, and extrusion width on dimensional deviation and surface roughness using 5 × 5 × 5 mm cube specimens. Dimensional accuracy was quantified along the horizontal and vertical axes, and surface roughness was measured using a stylus profilometer. Statistical analysis showed layer height was the most significant factor affecting horizontal accuracy (p = 0.0225), while printing speed most strongly influenced vertical deviation. The optimal parameters, 450 °C nozzle temperature, 0.06 mm layer height, 7.5 mm/s printing speed, and 0.4 mm extrusion width, achieved mean deviations of 0.013 mm (horizontal) and 0.049 mm (vertical) with a surface roughness of 4.01 µm. Validation using a benchmark model and micro-computed tomography confirmed improved reproduction of small features under these conditions. The results demonstrate that precise control of FDM parameters enables accurate fabrication of sub-millimeter PEEK structures suitable for medical device applications.
more »
« less
This content will become publicly available on January 1, 2027
Influence of fused deposition modeling parameters on the mechanical and thermal properties of 3D-printed PEEK dental endosseous implants
Not AvailableObjectives: This study aims to explore the application of Fused Deposition Modeling (FDM) as a 3D printing technique for developing endosseous Polyetheretherketone (PEEK) dental implants. Specifically, the primary aim of the study is to systematically investigate the effects of key FDM processing parameters, including thermal conditions, print speed, layer height, build orientation, and post-processing heat treatments, on the mechanical and thermal properties of PEEK implants. By conducting an in-depth analysis, this study aims to establish optimized processing guidelines for the reliable manufacturing of high-performance, clinically viable PEEK dental implants. Methods: PEEK dental implants were fabricated using FDM with variations in thermal conditions (nozzle, bedplate, and chamber temperatures), print speed, layer height, build orientation, and post-print heat treatments. Mechanical testing (compression and fatigue), detailed thermal characterization using Differential Scanning Calorimetry (DSC), and fractographic analysis were performed. Finite Element Analysis (FEA) was also conducted to understand the implant's load-bearing performance. Results: Nozzle temperature dictates implant resolution, while chamber temperature is a key determinant of implant crystallinity. Interestingly, for PEEK dental implants, all the FDM thermal processing conditions play a crucial role in influencing the part's thermal properties. Moreover, print speed plays an essential role in developing dimensionally accurate high-strength implants. Notably, the fractographic analysis of the failed implants revealed interesting multimodal fracture behavior specific to 3D-printed threaded implants. FEA demonstrates that the implants tend to buckle under load and break at the implant-abutment interface, consistent with experimental results. Furthermore, fatigue testing reveals that PEEK implants, fabricated at a specific build orientation with respect to the bedplate, suffice the Food and Drug Administration durability requirements. Significance: These findings underscore the clinical potential of FDM-developed PEEK as a customizable, lightweight, and durable alternative to conventional metallic implants, paving the way for next-generation patient-specific lightweight dental implant solutions
more »
« less
- Award ID(s):
- 2152135
- PAR ID:
- 10691226
- Publisher / Repository:
- Elsevier
- Date Published:
- Journal Name:
- Dental Materials
- Volume:
- 42
- Issue:
- 1
- ISSN:
- 0109-5641
- Page Range / eLocation ID:
- 109 to 125
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Owing to its superior bulk mechanical properties, poly (ether ether ketone) (PEEK) has gained popularity over the past 15 years as a metal substitute in biomedical implants. Low surface energy is a fundamental issue with PEEK implants. This low surface energy caused by a moderately hydrophobic surface may be able to inhibit cellular adherence and result in the development of an inflammatory response, which may result in cell necrosis and apoptosis. In this work, plasma and ozone treatments have been utilized to surface activate PEEK and graft ionic bioactive polymer polyNaSS (poly (sodium styrene sulfonate)) successfully on the surface to promote cellular attachment and biomineralization. The main goal of our research has been to find a stable green process for surface modification of PEEK by plasma/ozone approaches to increase PolyNaSS grafting efficiency and biomineralization. To further the field of bioactive orthopedic and dental implant technology, this research attempts to address a significant constraint of PEEK implants while preserving their favorable mechanical properties.more » « less
-
Abstract Orbital implants are necessary for reconstructing fractured orbital walls and are traditionally fabricated using titanium or polyethylene, but these materials result in medical complications such as increased risk of implant migration and hemorrhaging. Therefore, orbital implants constructed from biocompatible and biodegradable polymers have been recently researched to mitigate these risks. Material extrusion three-dimensional (3D) printing techniques, especially fused deposition modeling (FDM), can be applied to produce patient-specific orbital implants. However, current structures fabricated by FDM usually possess poor mechanical properties and high surface roughness. In this work, an embedded FDM method is designed and implemented to fabricate polycaprolactone (PCL) orbital implants with increased mechanical properties and surface morphology through the development and utilization of a temperature-stable yield-stress suspension comprised of fumed silica particles and a sunflower oil solvent. The rheological properties of the suspension were measured and tuned to produce a viable support bath material above the melting temperature of PCL. Filaments, single-layer sheets, and tensile test samples were printed to optimize the printing parameters, verify the surface morphology, and validate the mechanical properties, respectively. After that, a numerical simulation was performed to determine the mechanical robustness of the designed orbital implant model. Finally, the orbital implant was printed, measured, and implanted into a mock-up orbital socket to verify the viability of the proposed embedded FDM method.more » « less
-
The human skull can become fractured or injured through impact and often requires repair through a craniectomy and subsequent cranioplasty, surgery performed to repair defects or damage to the cranium. Challenges related to material choice, which must be biocompatible, and customization for each patient’s anatomy remain. One possible solution is fabrication of patient-specific cranial implants, out of biocompatible polymers, using single point incremental forming (SPIF). In this paper, polyetheretherketone (PEEK) and ultra-high molecular weight polyethylene (UHMWPE) are formed using SPIF at room temperature to manufacture a cranial implant. The SPIF process is used to produce formed parts from which test specimens were extracted to evaluate the tensile performance and thermal properties. Formed cranial implants were impacted using a drop weight to evaluate their suitability under relevant conditions. The geometric conformance of the SPIF process was studied to compare the material behavior for the specified polymers after forming. The results validate that SPIF can be conducted at room temperature with PEEK and UHMWPE biocompatible polymers to enable custom implant manufacturing. However, PEEK exhibited superior performance in terms of tensile strength, geometric conformance, energy absorption, and melting temperature, and is recommended over UHMWPE for future implant applications.more » « less
-
ABSTRACT IntroductionThe cervical spine, pivotal for mobility and overall body function, can be affected by cervical spondylosis, a major contributor to neural disorders. Prevalent in both general and military populations, especially among pilots, cervical spondylosis induces pain and limits spinal capabilities. Anterior Cervical Discectomy and Fusion (ACDF) surgery, proposed by Cloward in the 1950s, is a promising solution for restoring natural cervical curvature. The study objective was to investigate the impacts of ACDF implant design on postsurgical cervical biomechanics and neurorehabilitation outcomes by utilizing a biofield head-neck finite element (FE) platform that can facilitate scenario-specific perturbations of neck muscle activations. This study addresses the critical need to enhance computational models, specifically FE modeling, for ACDF implant design. Materials and MethodsWe utilized a validated head-neck FE model to investigate spine–implant biomechanical interactions. An S-shaped dynamic cage incorporating titanium (Ti) and polyetheretherketone (PEEK) materials was modeled at the C4/C5 level. The loading conditions were carefully designed to mimic helmet-to-helmet impact in American football, providing a realistic and challenging scenario. The analysis included intervertebral joint motion, disk pressure, and implant von Mises stress. ResultsThe PEEK implant demonstrated an increased motion in flexion and lateral bending at the contiguous spinal (C4/C5) level. In flexion, the Ti implant showed a modest 5% difference under 0% activation conditions, while PEEK exhibited a more substantial 14% difference. In bending, PEEK showed a 24% difference under 0% activation conditions, contrasting with Ti’s 17%. The inclusion of the head resulted in an average increase of 18% in neck angle and 14% in C4/C5 angle. Disk pressure was influenced by implant material, muscle activation level, and the presence of the head. Polyetheretherketone exhibited lower stress values at all intervertebral disc levels, with a significant effect at the C6/C7 levels. Muscle activation level significantly influenced disk stress at all levels, with higher activation yielding higher stress. Titanium implant consistently showed higher disk stress values than PEEK, with an orders-of-magnitude difference in von Mises stress. Excluding the head significantly affected disk and implant stress, emphasizing its importance in accurate implant performance simulation. ConclusionsThis study emphasized the use of a biofidelic head-neck model to assess ACDF implant designs. Our results indicated that including neck muscles and head structures improves biomechanical outcome measures. Furthermore, unlike Ti implants, our findings showed that PEEK implants maintain neck motion at the affected level and reduce disk stresses. Practitioners can use this information to enhance postsurgery outcomes and reduce the likelihood of secondary surgeries. Therefore, this study makes an important contribution to computational biomechanics and implant design domains by advancing computational modeling and theoretical knowledge on ACDF–spine interaction dynamics.more » « less
An official website of the United States government