Title: The Evaluation of the ForenSeq™ MainstAY Kit for Mixed Forensic DNA Samples
Next Generation Sequencing (NGS) has been widely considered to be the future of forensic casework, with increasing numbers of labs beginning to implement it into their workflows alongside, or even in place of, traditional Capillary Electrophoresis (CE). There are numerous advantages to NGS such as shorter amplicons, increased sensitivity, the potential detection of isoalleles, and the massive number of markers and marker types that can be run simultaneously. One main limiting factor, though, is plexity, the number of samples that can be run at once. Plexity is affected by the physical capacity of the flow cell, which facilitates the formation of clusters that each represent a distinct PCR target (DPT). Since only so many DPTs can fit on the flow cell, the read coverage at each locus in an NGS run is highly dependent on the flow cell’s capacity, the number of markers in the kit, and the number of DPTs generated during the PCR process. The total number of DPTs includes things like forward and back stutter as well as the alleles. More loci and higher numbers of contributors result in higher DPTs. Verogen’s™ recently released ForenSeq™ MainstAY kit is specifically aimed at a forensically relevant set of 27 autosomal STR and 25 Y-STR markers. It uses the MiSeq® FGx Reagent Micro Kit, with a flow cell capable of five million reads. This combination of markers and flow cell capacity should allow full coverage of a run of 96 single-source samples. However, forensic casework samples are rarely this simple. Labs regularly process samples that contain a mixture of two or more contributors, often with low-level trace donors. Mixed samples can multiply the number of DPTs present, causing a 96-sample run that should fall within the capacity of the flow cell to exceed it, reducing the effective coverage of each locus. In addition, the increased sensitivity promised by NGS has not yet been fully explored for mixed samples, especially for batched samples such as sexual assault swabs, which commonly have very high female-to-male mixture ratios. Such samples, if included in a full run of 96 libraries, must compete for space on the flow cell for detection. The study presented here aimed to test the limits of MainstAY’s plexity by simultaneously running a variety of sample types and mixtures that would be typically encountered in forensic casework. The presentation will explore the trade-off of more rare genotypes due to isoalleles against detection challenges due to extreme plexity and competition for a spot on the flow cell. Additionally, properties unique to NGS such as sequence-specific stutter models will be explored. Last, the presentation will provide recommendations for optimal batching of samples for an efficient NGS case processing workflow.  more » « less
Award ID(s):
2311009
PAR ID:
10692634
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Proceedings of the American Academy of Forensic Sciences (2023)
Date Published:
Subject(s) / Keyword(s):
Next Generation Sequencing Plexity Isoalleles
Sponsoring Org:
National Science Foundation
More Like this
  1. Amplification of STRs using Polymerase Chain Reaction (PCR) is the foundation of current forensic DNA analysis methods throughout the world. While it remains the gold standard, an inevitable drawback of this process is the production of stutter artifacts due to strand slippage during PCR. Stutter appears as smaller peaks typically positioned one or two repeat units away from an allele peak on an electropherogram and can cause issues in interpretation or mixture deconvolution if not accounted for effectively. Current DNA analysis software attempts to recognize the expected occurrence of stutter and allow analysts to remove it from the allelic data. These stutter models have evolved over time from locus-specific thresholds to allelespecific filters based on a linear relationship between stutter peak height ratio and allele number.1 While this allele-specific stutter modeling offers improvements over the locus-specific thresholds in more accurately predicting the occurrence of stutter in simple loci, loci with more complex repeat units tend to show major deviation from the linear model, suggesting that additional factors may still need to be considered. The advancement and growing adoption of NGS technology offers exciting new possibilities for stutter modeling. NGS still allows laboratories to assess STR marker length but provides the additional ability to view their sequences, which can reveal differences in STR alleles that would have appeared identical on CE. These differences could potentially be used to develop a more accurate model for stutter filtering based not only on allele, but also on characteristics of the sequence. This presentation details part of a study that sequenced batches of 96 and 32 single-source samples for autosomal and Y-chromosomal Short Tandem Repeats (Y-STRs) using the QIAGEN® ForenSeq™ MainstAY Kit. These sequence data were used to develop a model for sequence-specific stutter to explore its potential effectiveness in comparison to locus- or allele-based stutter filter model. While preliminary data suggests that additional sequence characteristics may still need to be considered, this presentation will demonstrate stutter ratio plots showing improved R2 measures of linearity at complex loci when considering the Longest Uninterrupted Stretch (LUS) in the repeat unit of the STR sequence rather than allele number.2 Others have looked at various characteristics of NGS stutter before; however, this stutter model is the first to also incorporate the simplicity of the Sequence Identifier (SID) nomenclature first described by Young et al.3-5 These NGS stutter models will ultimately need to be incorporated into analysis and PG software to take full advantage of the potential interpretation and deconvolution improvements. While stutter data from many more samples will be needed, along with validation tools and downstream software, this presentation will serve as an introduction of sequence-specific stutter to the forensic community. References: 1. Kalafut T, Schuerman C, Sutton J, Faris T, Armogida L, Bright JA, et al. Implementation and validation of an improved allele specific stutter filtering method for electropherogram interpretation. Forensic Sci Int Genet. 2018;35:50-6. 10.1016/j.fsigen.2018.03.016. 2. Bright JA, Taylor D, Curran JM, Buckleton JS. Developing allelic and stutter peak height models for a continuous method of DNA interpretation. Forensic Sci Int Genet. 2013;7(2):296-304. 10.1016/j.fsigen.2012.11.013. 3. D’Angelo O, Vandepoele ACW, Adelman J, Marciano MA. Assessing non-LUS stutter in DNA sequence data. Forensic Sci Int Genet. 2022;59:102706. 10.1016/j.fsigen.2022.102706. 4. Agudo MM, Aanes H, Roseth A, Albert M, Gill P, Bleka O. A comprehensive characterization of MPS-STR stutter artefacts. Forensic Sci Int Genet. 2022;60:102728. 10.1016/j.fsigen.2022.102728. 5. Young B, Faris T, Armogida L, Meles V. The sequence identifier (SID): Nomenclature for mixed-DNA casework using MPS. Forensic Science International: Genetics Supplement Series. 2019;7. 10.1016/j.fsigss.2019.10.125. 
    more » « less
  2. In many human identification (HID) cases only skeletal remains are recovered and may require complex DNA typing methods. The gold standard in DNA typing involves the analysis of STR markers; however, low-template, inhibited, and fragmented skeletal samples often results in partial profiles, limiting definitive identifications. More advanced methods may provide better identifications and additional investigative leads. Extracts were collected from challenging (buried, burned, cremated, embalmed, and surface decomposed) skeletal samples and analyzed using three downstream processing methods; STR typing (Investigator 24plex QS; QIAGEN), microarray SNP typing (Infinium Global Screening Array; Illumina Inc.), and next generation sequencing (NGS) techniques (ForenSeq Signature Prep Kit and ForenSeq Kintelligence Kit; Verogen). By examining the overall success of each method compared to each extract's DNA quantity and quality, a recommendation on the best-suited method can be determined. Traditional STR typing provided complete STR profiles in several samples; however, the two NGS methods exhibited increased success with low-template and degraded samples. The ForenSeq Signature Prep kit and the ForenSeq Kintelligence kit demonstrated success with as little as 100 pg of DNA. Both methods provided additional investigative leads through phenotypic and ancestry predictions or forensic genetic genealogy leads. Additionally, coupling the enhanced PCR buffer with the ForenSeq Signature Prep kit resulted in increased intensity, or number of reads, as well as increased SNP call rates for the majority of samples. The Infinium Global Screening Array also demonstrated improved sensitivity for forensically relevant SNPs with as low as 200 pg DNA input. These data indicate the potential success of HID from compromised skeletal remains utilizing a variety of downstream processing techniques depending on the quantity and quality of DNA available. 
    more » « less
  3. Abstract Formalin‐fixed tissues provide the medical and forensic communities with alternative and often last resort sources of DNA for identification or diagnostic purposes. The DNA in these samples can be highly degraded and chemically damaged, making downstream genotyping using short tandem repeats (STRs) challenging. Therefore, the use of alternative genetic markers, methods that pre‐amplify the low amount of good quality DNA present, or methods that repair the damaged DNA template may provide more probative genetic information. This study investigated whether whole genome amplification (WGA) and DNA repair could improve STR typing of formaldehyde‐damaged (FD) tissues from embalmed cadavers. Additionally, comparative genotyping success using bi‐allelic markers, including INDELs and SNPs, was explored. Calculated random match probabilities (RMPs) using traditional STRs, INDEL markers, and two next generation sequencing (NGS) panels were compared across all samples. Overall, results showed that neither WGA nor DNA repair substantially improved STR success rates from formalin‐fixed tissue samples. However, when DNA from FD samples was genotyped using INDEL and SNP‐based panels, the RMP of each sample was markedly lower than the RMPs calculated from partial STR profiles. Therefore, the results of this study suggest that rather than attempting to improve the quantity and quality of severely damaged and degraded DNA prior to STR typing, a more productive approach may be to target smaller amplicons to provide more discriminatory DNA identifications. Furthermore, an NGS panel with less loci may yield better results when examining FD samples, due to more optimized chemistries that result in greater allelic balance and amplicon coverage. 
    more » « less
  4. While skeletal remains are known for their resilience and often serve as the final source of information for unidentified human remains (UHRs), the traditional downstream processing of these samples is challenging due to their low template nature, DNA degradation, and the presence of PCR inhibitors, typically resulting in limited probative information. To address this issue, advanced genotyping methods can be explored to retrieve additional genetic information from these challenging samples to maximize investigative leads. Therefore, this study investigated the effectiveness of three advanced genotyping methods and assessed their suitability with compromised skeletal samples: 1) targeted next generation sequencing (NGS) of both STRs and SNPs using the ForenSeq® DNA Signature Prep chemistry, 2) targeted NGS of SNPs using the ForenSeq® Kintelligence kit, and 3) SNP genotyping using a microarray via the Infinium Global Screening Array. The genotype recovery and added investigative leads were compared across all methods. All three approaches demonstrated success with the challenging skeletal samples used in this study. Specifically, the ForenSeq® DNA Signature Prep chemistry outperformed traditional STR typing by improving the recovery of CODIS core loci. Additionally, the ForenSeq® Kintelligence kit and Infinium Global Screening Array provided eligible results for forensic investigative genetic genealogy (FIGG) searching. Based on these successes, we have developed a proposed workflow for downstream processing of challenging skeletal samples. Following the guidelines of the US Department of Justice, the recovery of the CODIS core loci should be attempted through traditional CE-based methods or a NDIS-approved NGS chemistry, such as ForenSeq® DNA Signature Prep. Alternatively, a mitochondrial DNA profile may be uploaded to CODIS for comparisons in UHR cases. However, if no probative information is developed from the forensic profile uploaded to CODIS, then FIGG methods can be implemented using the Infinium Global Screening Array for high-quality skeletal samples (DNA concentrations ≥ 0.5 ng/μL) or the ForenSeq® Kintelligence chemistry for low-template skeletal remains (DNA concentration ≤ 0.5 ng/μL). These findings provide valuable insight into the suitability and efficacy of advanced genotyping methods, offering promising opportunities for enhancing the investigation of cases involving UHRs. 
    more » « less
  5. Often, only skeletal remains are available in human identification cases, requiring challenging DNA typing methods on these samples for definitive identifications. The low-template nature, prevalence of inhibitors, and fragmentation commonly found in skeletal samples complicates this task of human identification through DNA typing and requires additional research on suitable DNA extraction, purification, and downstream processing techniques.1,2 InnoXtract™ (InnoGenomics Technologies) extraction and purification system designed for DNA extraction from low-template samples, specifically rootless hair shafts.3 In addition, its ability to capture highly fragmented DNA suggested its suitability for use with skeletal samples3. However, the lysis and digestion parameters required modifications to optimize the method for this sample type. Preliminary studies determined that InnoXtract™ purification parameters were most compatible with PrepFiler™ BTA (Thermo Fisher Scientific) lysis parameters; therefore, InnoXtract™ lysis parameters were designed similarly to this method. A two-part digestion was developed using a homebrew digestion buffer (0.5M EDTA, 0.05% Tween 20, and 100 mM NaCl) and a supplemental lysis with the hair digestion buffer included in the InnoXtract™ kit. The InnoXtract™ purification parameters were also modified to better suit skeletal samples by increasing the volume of magnetic beads allowing for maximal capture of DNA fragments. Following these modifications, the optimal volume of sample input was examined. The optimized InnoXtract™ method provided extracts with similar quality and quantity of recovered DNA compared to the commercial skeletal extraction method, PrepFiler™ BTA. The optimized InnoXtract™ and PrepFiler™ BTA extraction methods were performed on various challenging skeletal samples (from surface decomposed, buried, embalmed, burned, and cremated remains). These extracts will be analyzed using three downstream processing methods; STR typing (Investigator 24plex QS; QIAGEN), microarray SNP typing (Infinium Global Screening Array; Illumina Inc.), and massively parallel sequencing techniques (ForenSeq Signature Prep Kit and ForenSeq Kintelligence Kit; Verogen). By examining the overall success of each method compared to each extract's DNA quantity/quality, a recommendation on the best-suited method will be determined. Initial data indicates several extracts have sufficient DNA recovery to yield complete STR profiles. Additionally, the Global Screening Array demonstrated sensitivity for DNA input down to 200 pg, indicating the improved sensitivity for forensically relevant SNPs. The ForenSeq Kintelligence kit provided an average total call rate of 9938 ± 258 SNPs at 1 ng input from challenging skeletal remains. These data indicate the potential success of this new extraction method with compromised skeletal remains utilizing a variety of downstream processing techniques. This presentation will highlight the success of the newly optimized InnoXtract™ method for DNA extraction and purification from skeletal samples and demonstrate what downstream process should be implemented depending on each extract's DNA quantity and quality. Reference(s): 1. O.M. Loreille; T.M. Diegoli; J.A. Irwin; M.D. Coble; T.J. Parsons. High efficiency DNA extraction from bone by total demineralization. Forensic Sci. Int. Genet. 1 (2007) 191–195. https://doi.org/10.1016/j.fsigen.2007.02.006. 2. J. Rothe; M. Nagy. Comparison of two silica-based extraction methods for DNA isolation from bones. Legal Medicine. 22 (2016) 36–41. https://doi.org/10.1016/j.legalmed.2016.07.008. 3. InnoGenomics Technologies, InnoXtract, InnoGenomics. (2019). https://innogenomics.com/products/innoxtract/ (accessed October 21, 2020). 
    more » « less