Knowledge of rheological properties, such as viscosity and elasticity, is necessary for efficient material processing and transportation as well as biological analysis. Existing rheometers operate with large sample volume and induce sample contact with container or device walls, which are inadequate for rheological analysis of sensitive fluids limited in availability. In this work, we introduce acoustic tweezing spectroscopy (ATS), a novel noncontact rheological technique that operates with a single 4–6 μl drop of fluid sample. In ATS, a sample drop is acoustically levitated and then exposed to a modulated acoustic signal to induce its forced oscillation. The time-dependent sample viscosity and elasticity are measured from the resulting drop response. The ATS measurements of polymeric solutions (dextran, xanthan gum, gelatin) agree well with previously reported data. The ATS predicts that the shear viscosity of blood plasma increases from 1.5 cP at 1.5 min of coagulation onset to 3.35 cP at 9 min, while its shear elastic modulus grows from a negligible value to 10.7 Pa between 3.5 min and 6.5 min. Coagulation increases whole blood viscosity from 5.4 cP to 20.7 cP and elasticity from 0.1 Pa to 19.2 Pa at 15 min. In summary, ATS provides the opportunity for sensitive small-volume rheological analysis in biomedical research and medical, pharmaceutical, and chemical industries.
more »
« less
This content will become publicly available on April 30, 2027
A novel imaging-based multi-sample viscometry application for advancing monoclonal antibody development
The increasing demand for monoclonal antibodies (mAbs) as therapeutic agents highlights the ever-growing necessity of optimizing sample-selection procedures; the rate-limiting step of therapy development. One such mAb property test is viscosity, which affects syringeability, concentration dose, and patient experience. Current viscometry methods, such as cone and plate rheometry, although accurate, are limited by low throughput, high sample volume requirements, and lack of automation, driving up the cost and time of mAb development. This paper introduces an innovative imaging-based viscometry application that significantly mitigates these issues. By integrating a wide-field camera with a fluorescence microscope and Python-based single particle tracking (SPT) software, this approach allows for rapid, low-volume (down to 2μl) viscosity measurements of mAb solutions. Using 200 nm yellow–green fluorescent polystyrene beads as tracers, the system ensures accurate macroviscosity assessments of protein solutions and the capability for high-throughput analysis. The platform’s precision and sensitivity were validated using bovine serum albumin and viscosity standard solutions, followed by a single-blinded study using Immunoglobulin G1 and G2 (IgG1/IgG2) solutions of varying concentrations (⩽150 mg ml−1) and viscosities (2–31 cP). When compared to the unblinded values, the SPT blinded sample analysis resulted in a linear fit ofR2= 0.97 and an average error of 2.1 cP. Our findings suggest that this novel platform can substantially streamline and enhance the mAb development process, offering a feasible solution to one of the industry’s pressing challenges.
more »
« less
- Award ID(s):
- 1841509
- PAR ID:
- 10692885
- Publisher / Repository:
- IOP Publishing
- Date Published:
- Journal Name:
- Methods and Applications in Fluorescence
- Volume:
- 14
- Issue:
- 2
- ISSN:
- 2050-6120
- Page Range / eLocation ID:
- 025008
- Subject(s) / Keyword(s):
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract We measure the stacked lensing signal in the direction of galaxy clusters in the Dark Energy Survey Year 3 (DES Y3) redMaPPer sample, using cosmic microwave background (CMB) temperature data from SPT-3G, the third-generation CMB camera on the South Pole Telescope (SPT). Here, we estimate the lensing signal using temperature maps constructed from the initial 2 years of data from the SPT-3G 'Main' survey, covering 1500 deg2of the Southern sky. We then use this lensing signal as a proxy for the mean cluster mass of the DES sample. The thermal Sunyaev-Zel'dovich (tSZ) signal, which can contaminate the lensing signal if not addressed, is isolated and removed from the data before obtaining the mass measurement. In this work, we employ three versions of the redMaPPer catalogue: a Flux-Limited sample containing 8865 clusters, a Volume-Limited sample with 5391 clusters, and a Volume&Redshift-Limited sample with 4450 clusters. For the three samples, we detect the CMB lensing signal at a significance of 12.4σ, 10.5σand 10.2σand find the mean cluster masses to be M200m= 1.66±0.13 [stat.]± 0.03 [sys.], 1.97±0.18 [stat.]± 0.05 [sys.], and 2.11±0.20 [stat.]± 0.05 [sys.]×1014M⊙, respectively. This is a factor of ∼ 2 improvement relative to the precision of measurements with previous generations of SPT surveys and the most constraining cluster mass measurements using CMB cluster lensing to date. Overall, we find no significant tensions between our results and masses given by redMaPPer mass-richness scaling relations of previous works, which were calibrated using CMB cluster lensing, optical weak lensing, and velocity dispersion measurements from various combinations of DES, SDSS and Planck data. We then divide our sample into 3 redshift and 3 richness bins, finding no significant discrepancies with optical weak-lensing calibrated masses in these bins. We forecast a 5.7% constraint on the mean cluster mass of the DES Y3 sample with the complete SPT-3G surveys when using both temperature and polarization data and including an additional ∼ 1400 deg2of observations from the 'Extended' SPT-3G survey.more » « less
-
None (Ed.)Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼105–109) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding ofN-acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.more » « less
-
Abstract Fluids and melts in planetary interiors significantly influence geodynamic processes from volcanism to global‐scale differentiation. The roles of these geofluids depend on their viscosities (η). Constraining geofluidηat relevant pressures and temperatures relies on laboratory‐based measurements and is most widely done using Stokes' Law viscometry with falling spheres. Yet small sample chambers required by high‐pressure experiments introduce significant drag on the spheres. Several correction schemes are available for Stokes' Law but there is no consensus on the best scheme(s) for high‐pressure experiments. We completed high‐pressure experiments to test the effects of (a) the relative size of the sphere diameter to the chamber diameter and (b) the top and bottom of the chamber, that is, the ends, on the sphere velocities. We examined the influence of current correction schemes on the estimated viscosity using Monte Carlo simulations. We also compared previous viscometry work on various geofluids in different experimental setups/geometries. We find the common schemes for Stokes' Law produce statistically distinct values ofη. When inertia of the sphere is negligible, the most appropriate scheme may be the Faxén correction for the chamber walls. Correction for drag due to the chamber ends depends on the precision in the sinking distance and may be ineffective with decreasing sphere size. Combining the wall and end corrections may overcorrectη. We also suggest the uncertainty inηis best captured by the correction rather than propagated errors from experimental parameters. We develop an overlying view of Stokes' Law viscometry at high pressures.more » « less
-
Abstract We present a catalog of 500 galaxy cluster candidates in the SPT-Deep field: a 100 deg2field that combines data from the SPT-3G and SPTpol surveys to reach noise levels of 3.0, 2.2, and 9.0μK-arcmin at 95, 150, and 220 GHz, respectively. Candidates are selected via the thermal Sunyaev–Zel’dovich (SZ) effect with a minimum significance ofξ = 4.0, resulting in a catalog of purity ∼89%. Optical data from the Dark Energy Survey and infrared data from the Spitzer Space Telescope are used to confirm 442 cluster candidates. The clusters span 0.12 < z ≲ 1.8 and 1.0 × 1014M⊙/h70 < M500c < 8.7 × 1014M⊙/h70. The sample’s median redshift is 0.74, and the median mass is 1.7 × 1014M⊙/h70; these are the lowest median mass and highest median redshift of any SZ-selected sample to date. We assess the effect of infrared emission from cluster member galaxies on cluster selection by performing a joint fit to the infrared dust and tSZ signals by combining measurements from SPT and overlapping submillimeter data from Herschel/SPIRE. We find that at high redshift (z > 1), the tSZ signal is reduced by ( ) at 150 GHz (95 GHz) due to dust contamination. We repeat our cluster finding method on dust-nulled SPT maps and find the resulting catalog is consistent with the nominal SPT-Deep catalog, suggesting dust contamination does not significantly impact the SPT-Deep selection function; we attribute this lack of bias to the inclusion of the SPT 220 GHz band.more » « less
An official website of the United States government