Abstract The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real‐time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost‐effective method to prepare high‐quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)‐facets. The as‐fabricated TiO2film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin‐interfaced patch with microfluidic sampling and wireless transmission units for real‐time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
more »
« less
This content will become publicly available on January 1, 2027
Catalytic TiO 2 with Self‐Assembled Monolayer for Highly Sensitive, Selective, and Non‐Invasive Monitoring of Sweat L‐Cysteine
Abstract L‐cysteine plays a significant role in numerous physiological processes in the human body health, and monitoring its level has important clinical implications. However, L‐cysteine tests are limited to invasive blood drawing and a time‐consuming laboratory process, which also fails to give real‐time and continuous results. This study introduces a flexible electrochemical sensor based on a self‐assembled monolayer (SAM) of 3‐mercaptopropyltrimethoxysilane (MPTS) molecular receptor and catalytic titanium oxide‐modified carbon cloth (MPTS/TiO2/CC). The MPTS and TiO2modification serve as the artificial antibody through thiol interactions and the charge transfer layer, respectively, which is further confirmed by density function theory (DFT) calculations. The flexible L‐cysteine sensor based on MPTS/TiO2/CC shows a wide linear range of up to 500 µmand an ultra‐low limit of detection of 0.046 µm. A sweat patch consisting of an electrochemical sensing unit, a laser‐fabricated microfluidic channel, and a miniaturized electrochemical workstation affords real‐time monitoring of L‐cysteine detection in dynamic environments and reveals the strong correlation between sweat and blood L‐cysteine concentrations. The introduction of molecular receptors and band alignment may offer a general way of designing sensitive, specific electrochemical sensors for point‐of‐care diagnosis.
more »
« less
- PAR ID:
- 10694951
- Publisher / Repository:
- Wiley
- Date Published:
- Journal Name:
- Advanced Functional Materials
- Volume:
- 36
- Issue:
- 8
- ISSN:
- 1616-301X
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Although increasing efforts have been devoted to the development of non‐invasive wearable electrochemical sweat sensors for monitoring physiological and metabolic information, most of them still suffer from poor stability and specificity over time and fluctuating temperatures. This study reports the design and fabrication of a long‐term stable and highly sensitive flexible electrochemical sensor based on nanocomposite‐modified porous graphene by facile laser treatment for detecting biomarkers such as glucose in sweat. The laser‐reduced and patterned stable conductive nanocomposite on the porous graphene electrode provides the resulting glucose sensor with an excellent sensitivity of 1317.69 µA mm−1cm−2and an ultra‐low limit of detection of 0.079 µm. The sensor can also detect pH and exhibit extraordinary stability to maintain more than 91% sensitivity over 21 days in ambient conditions. Taken together with a temperature sensor based on the same material system, the dual glucose and pH sensor integrated with a flexible microfluidic sweat sampling network further results in accurate continuous on‐body glucose detection calibrated by the simultaneously measured pH and temperature. The low‐cost, highly sensitive, and long‐term stable platform could facilitate the early identification and continuous monitoring of different biomarkers for non‐invasive disease diagnosis and treatment evaluation.more » « less
-
Abstract This study presents the first investigation of a ReS2‐LaFeO3nanocomposite for the electrochemical detection of dopamine (DA). ReS2‐LaFeO3nanocomposites (5%, 10%, and 20% ReS2by weight) are synthesized hydrothermally on porous LaFeO3nanofibers prepared via electrospinning and annealing. The resulting materials are thoroughly characterized using spectroscopic and microscopic techniques. Electrochemical DA detection (0.02 µm– 1 mm) is performed using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA). The 10 wt.% ReS2‐LaFeO3nanocomposite demonstrates exceptional performance, achieving a high sensitivity of 0.191 µA µM⁻¹ cm⁻2. In comparison, LaFeO3, 5 wt.% ReS2‐LaFeO3, 20 wt.% ReS2‐LaFeO3, and pristine ReS2exhibit limits of detection (LODs) of 281, 357,187, and 120 µm, with corresponding sensitivities of 0.191, 0.156, 0.181, 0.183 µA µM⁻¹ cm⁻2, respectively. The representative 10 wt.% ReS2‐LaFeO3nanocomposite exhibits good selectivity and detection performance, as confirmed by tests with 1 mmconcentrations of common analytes in biological relevant chemicals such as uric acid (UA), sodium chloride (NaCl), hydrogen peroxide (H2O2), and ascorbic acid (AA). Furthermore, it shows varying response toward other neurotransmitters like epinephrine (EP) ad norepinephrine (NEP). The results of this investigation show that ReS2decoration on LaFeO3enhances the nanocomposite's physical, chemical, and electrical properties, leading to improved charge separation and reliable DA sensing in complex biological samples.more » « less
-
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2–CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM−1 cm−2), Tyr (0.126 µA µM−1 cm−2), and PA (0.0841 µA µM−1 cm−2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2–CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2–CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.more » « less
-
Wearable sweat biosensors offer compelling opportunities for improved personal health monitoring and non-invasive measurements of key biomarkers. Inexpensive device fabrication methods are necessary for scalable manufacturing of portable, disposable, and flexible sweat sensors. Furthermore, real-time sweat assessment must be analyzed to validate measurement reliability at various sweating rates. Here, we demonstrate a “smart bandage” microfluidic platform for cortisol detection and continuous glucose monitoring integrated with a synthetic skin. The low-cost, laser-cut microfluidic device is composed of an adhesive-based microchannel and solution-processed electrochemical sensors fabricated from inkjet-printed graphene and silver solutions. An antibody-derived cortisol sensor achieved a limit of detection of 10 pM and included a low-voltage electrowetting valve, validating the microfluidic sensor design under typical physiological conditions. To understand effects of perspiration rate on sensor performance, a synthetic skin was developed using soft lithography to mimic human sweat pores and sweating rates. The enzymatic glucose sensor exhibited a range of 0.2 to 1.0 mM, a limit of detection of 10 μM, and reproducible response curves at flow rates of 2.0 μL min −1 and higher when integrated with the synthetic skin, validating its relevance for human health monitoring. These results demonstrate the potential of using printed microfluidic sweat sensors as a low-cost, real-time, multi-diagnostic device for human health monitoring.more » « less
An official website of the United States government
