Title: Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold
Abstract The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c2) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.  more » « less
Award ID(s):
2310112 2411655
PAR ID:
10695308
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less
Corporate Creator(s):
Publisher / Repository:
IOPscience
Date Published:
Journal Name:
Journal of Instrumentation
Volume:
21
Issue:
03
ISSN:
1748-0221
Page Range / eLocation ID:
P03020
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Baracchini, Elisabetta (Ed.)
    The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10−42 cm2 at 1 GeV/c2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson. 
    more » « less
  2. A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4  keV showed sensitivity to ∼20  keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1  keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10−6 set at 0.50 keV, the lowest thermodynamic threshold explored. 
    more » « less
  3. Abstract The Recoil Directionality project (ReD) within the DarkSide-20k Collaboration characterizedthe response of a liquid argon (LAr) dual-phase Time Projection Chamber (TPC) to neutron induced nuclear recoils,to measure the ionization yield at low-energy. The ionization yield is a critical parameter for the experiments searchingfor Dark Matter in the form of low-mass WIMPs and measurements in Ar below 10 keV are scarce in theliterature. ReD was designed to cover the gap down to 2 keV. The ReD data taking took place in 2023 at the INFNSezione di Catania. The TPC was irradiated by neutrons from an intense252Cf fission source in orderto produce Ar recoils inthe energy range of interest. The energy of the nuclear recoils produced within the TPC by (n,n')scattering was determined by detecting the outgoing neutrons with a dedicated neutron spectrometermade of 18 plastic scintillators. The kinetic energy of neutrons interacting in the TPC was evaluatedevent-by-event by measuring the time of flight. ReD collected and characterized a sample of nuclearrecoils down to 2 keV, thus meeting its design goal.The ReD effort will be further extended by a new project, ReD+, funded by a PRIN grant from theItalian Ministry of Research. ReD+ is designed to push the sensitivity down to 0.5 keV, by using thesame conceptual design of ReD and improved components. A new TPC is being re-designed andoptimized in order to increase the signal rate and the signal-to-background ratio, which limited thesensitivity of ReD. 
    more » « less
  4. PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to O(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF3I and C3F8. The CF3I run consisted of 36.8 kg of CF3I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C3F8 runs consisted of 52 kg of C3F8 reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF3I bubble chamber used iodine as the target material. 
    more » « less
  5. Abstract Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of directional dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinise this hint. A small dual-phase argon TPC was irradiated with neutrons produced by the p(7Li,7Be)n reaction using the 15 MV TANDEM accelerator of the INFN - Laboratori Nazionali del Sud, Catania, Italy, so as to produce argon nuclear recoils in the range (20 - 100) keV of interest for dark matter searches. Energy and direction of nuclear recoils are inferred by the detection of the elastically-scattered neutron by a set of scintillation detectors. Events were selected by gating of the associated7Be, which is detected by a telescope of Si detectors. 
    more » « less