Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 5:00 PM ET until 8:00 PM ET on Friday, September 11 due to maintenance. We apologize for the inconvenience.


This content will become publicly available on December 1, 2026

Title: Characterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin
The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14(3)events/(kgdaykeV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of <9events/(kgdaykeV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5events/(kgdaykeV) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.  more » « less
Award ID(s):
2411390
PAR ID:
10696850
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less
Corporate Creator(s):
Publisher / Repository:
Physics Review D
Date Published:
Journal Name:
Physical Review D
Volume:
112
Issue:
11
ISSN:
2470-0010
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54±0.14keV FWHM and 1.18±0.02keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05counts/(keVkgdays) and 16±2counts/(keVkgdays) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50±2% and 26±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena. 
    more » « less
  2. In this work, we expand on the XENON1T nuclear recoil searches to study the individual signals of dark matter interactions from operators up to dimension eight in a chiral effective field theory (ChEFT) and a model of inelastic dark matter (iDM). We analyze data from two science runs of the XENON1T detector totaling 1t×yr exposure. For these analyses, we extended the region of interest from [4.9,40.9] keVNR to [4.9,54.4] keVNR to enhance our sensitivity for signals that peak at nonzero energies. We show that the data are consistent with the background-only hypothesis, with a small background overfluctuation observed peaking between 20 and 50 keVNR , resulting in a maximum local discovery significance of 1.7σ for the Vector Vectorstrange ChEFT channel for a dark matter particle of 70GeV/c2 and 1.8σ for an iDM particle of 50GeV/c2 with a mass splitting of 100keV/c2 . For each model, we report 90% confidence level upper limits. We also report upper limits on three benchmark models of dark matter interaction using ChEFT where we investigate the effect of isospin-breaking interactions. We observe rate-driven cancellations in regions of the isospin-breaking couplings, leading to up to 6 orders of magnitude weaker upper limits with respect to the isospin-conserving case. Published by the American Physical Society2024 
    more » « less
  3. The XENONnT experiment, located at the INFN Laboratori Nazionali del Gran Sasso, Italy, features a 5.9 tonne liquid xenon time projection chamber surrounded by an instrumented neutron veto, all of which is housed within a muon veto water tank. Because of extensive shielding and advanced purification to mitigate natural radioactivity, an exceptionally low background level of (15.8±1.3)events/(tonne·year·keV) in the (1,30) keV region is reached in the inner part of the time projection chamber. XENONnT is, thus, sensitive to a wide range of rare phenomena related to dark matter and neutrino interactions, both within and beyond the Standard Model of particle physics, with a focus on the direct detection of dark matter in the form of weakly interacting massive particles. From May 2021 to December 2021, XENONnT accumulated data in rare-event search mode with a total exposure of one tonne·year . This paper provides a detailed description of the signal reconstruction methods, event selection procedure, and detector response calibration, as well as an overview of the detector performance in this time frame. This work establishes the foundational framework for the “blind analysis” methodology we are using when reporting XENONnT physics results. Published by the American Physical Society2025 
    more » « less
  4. We search for dark matter (DM) with a mass [3,12]GeV/c2 using an exposure of 3.51tonneyear with the XENONnT experiment. We consider spin-independent DM-nucleon interactions mediated by a heavy or light mediator, spin-dependent DM-neutron interactions, momentum-dependent DM scattering, and mirror DM. Using a lowered energy threshold compared to the previous weakly interacting massive particle search, a blind analysis of [0.5, 5.0] keV nuclear recoil events reveals no significant signal excess over the background. XENONnT excludes spin-independent DM-nucleon cross sections >2.5×1045cm2 at 90% confidence level for 6GeV/c2 DM. In the considered mass range, the DM sensitivity approaches the “neutrino fog,” the limitation where neutrinos produce a signal that is indistinguishable from that of light DM-xenon nucleus scattering. Published by the American Physical Society2025 
    more » « less
  5. We measure the complete set of angular coefficients Ji for exclusive B¯ D* ν¯ decays ( =e , μ ). Our analysis uses the full 711fb1 Belle dataset with hadronic tag-side reconstruction. The results allow us to extract the form factors describing the B¯D* transition and the Cabibbo-Kobayashi-Maskawa matrix element | Vcb | . Using recent lattice QCD calculations for the hadronic form factors, we find | Vcb |=(40.7±0.7)×103 using the Boyd-Grinstein-Lebed parametrization, compatible with determinations from inclusive semileptonic decays. We search for lepton flavor universality violation as a function of the hadronic recoil parameter w and investigate the differences of the electron and muon angular distributions. We find no deviation from standard model expectations. Published by the American Physical Society2024 
    more » « less