Title: A review of NEST models for liquid xenon and an exhaustive comparison with other approaches
This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.  more » « less
Award ID(s):
2310091
PAR ID:
10704840
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more » ; ; ; ; ; ; « less
Publisher / Repository:
Frontiers in Detector Science and Technology
Date Published:
Journal Name:
Frontiers in Detector Science and Technology
Volume:
2
ISSN:
2813-8031
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $${}^{37}$$ 37 Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be ( $$32.3\,\pm \,0.3$$ 32.3 ± 0.3 ) photons/keV and ( $$40.6\,\pm \,0.5$$ 40.6 ± 0.5 ) electrons/keV, respectively, in agreement with other measurements and with NEST predictions. The electron yield at 0.27 keV is also measured and it is ( $$68.0^{+6.3}_{-3.7}$$ 68 . 0 - 3.7 + 6.3 ) electrons/keV. The $${}^{37}$$ 37 Ar calibration confirms that the detector is well-understood in the energy region close to the detection threshold, with the 2.82 keV line reconstructed at ( $$2.83\,\pm \,0.02$$ 2.83 ± 0.02 ) keV, which further validates the model used to interpret the low-energy electronic recoil excess previously reported by XENON1T. The ability to efficiently remove argon with cryogenic distillation after the calibration proves that $${}^{37}$$ 37 Ar can be considered as a regular calibration source for multi-tonne xenon detectors. 
    more » « less
  2. Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double- β decay detector ( ∼5 metric ton, 90% Xe136 , 10% Xe134 ) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae. Published by the American Physical Society2024 
    more » « less
  3. Abstract Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology, high-voltage electrodes are instrumental for the generation of observable signals and their physical interpretation. Thus, electrode design and manufacturing has to fulfill stringent requirements, and their production is associated with significant engineering challenges. In this work we describe the successful development of electrodes on the 1.5 m-scale, from their design and simulation to subsequent assembly and high-voltage testing in a gaseous argon environment. The produced electrodes were recently installed as an anode and a cathode during an upgrade to the XENONnT experiment. 
    more » « less
  4. Abstract We study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0 νββ ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0 νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC. 
    more » « less
  5. We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time. 
    more » « less