Title: Data from: BubbleID: A deep learning framework for bubble interface dynamics analysis
Abstract: This paper presents BubbleID, a sophisticated deep learning architecture designed to comprehensively identify both static and dynamic attributes of bubbles within sequences of boiling images. By amalgamating segmentation powered by Mask R-CNN with SORT-based tracking techniques, the framework is capable of analyzing each bubble's location, dimensions, interface shape, and velocity over its lifetime and capturing dynamic events such as bubble departure. BubbleID is trained and tested on boiling images across diverse heater surfaces and operational settings. This paper also offers a comparative analysis of bubble interface dynamics prior to and post-critical heat flux conditions. TechnicalInfo: # Data from: BubbleID: A deep learning framework for bubble interface dynamics analysis Dataset DOI: [10.5061/dryad.ksn02v7gx](10.5061/dryad.ksn02v7gx) ## Description of the data and file structure This dataset includes raw bubble images, annotated images, and saved model weights for [BubbleID](https://github.com/cldunlap73/BubbleID), an open-source package for bubble identification, tracking, and analysis, and liquid-vapor interface dynamics analysis. The bubble images are collected using a high-speed camera (Phantom VEO 710L) during pool boiling tests performed using the facility described in [Pandey et al. 2024.](https://www.sciencedirect.com/science/article/pii/S1359431123018367) The bubble images are manually annotated for the liquid-vapor interfaces using the [labelme](https://anaconda.org/conda-forge/labelme) package.  ### Files and variables #### File: ned3-001\_BubbleID.zip **Description:** The zip file includes four folders, i.e., AnnotatedData, Models, TestData, and Tutorials.  The *AnnotatedData* folder includes two subfolders and a readme file. This dataset contains pool boiling image data and annotations made in labelme. * Classes-1: Annotations for liquid-vapor interfaces, including the training set, testing set, and a set from one pool boiling experiment, which does not appear in the other folders (Unseen-Test). - Classes-2: Annotations for bubbles distinguishing between attached and detached bubbles. The *Models* folder includes PyTorch model checkpoint file (.pth) saving the weights of preitrained models, including * seg_model.pth: pre-trained instance segmentation model * class_model.pth: pre-trained classification model The *TestData* includes two subfolders:  * SteadyStateTest for image sequences sampled at 3000 fps.  * TransientSmallTst for image sequences sampled at 150 fps.  The *tutorial* folder includes a Python Notebook script illustrating the steps for using the pretrained model and the BubbleID class for saving and displaying data extracted from bubble images/ videos.  ## Code/software * The images (.jpg) and annotations (.json) can be viewed using the [labelme](https://anaconda.org/conda-forge/labelme "https://anaconda.org/conda-forge/labelme") package.  Yes (and it should be a simple as installing LabelMe and pointing to the directory of the images and JSON files. * The tutorial (.ipynb) can be opened using any Python Notebook packages, e.g., Jupyter Notebook, Google Colab. It can be viewed in Google Colab, but I don't think there is a way (at least not a simple one) to run it in Colab. It can be viewed in Jupyter Notebook and run there if installed correctly * The [PyTorch](https://pytorch.org/ "https://pytorch.org/") package can import the checkpoint file (.pth) in a Python script. This can be done by specifying the path to the weights using the BubbleID class, e.g., *test120=BubbleID.DataAnalysis(imagesfolder,videopath,savefolder,extension,modelweights,"cpu")*  more » « less
Award ID(s):
2323022
PAR ID:
10712576
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Dryad
Date Published:
Edition / Version:
6
Subject(s) / Keyword(s):
FOS: Mechanical engineering FOS: Mechanical engineering Boiling Computer vision Bubbles
Format(s):
Size: 946592578 bytes
Size(s):
946592578 bytes
Right(s):
Creative Commons Zero v1.0 Universal
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract: This paper presents Hit2Flux, a machine learning framework for boiling heat flux prediction using acoustic emission (AE) hits generated through threshold-based transient sampling. Unlike continuously sampled data, AE hits are recorded when the signal exceeds a predefined threshold and are thus discontinuous in nature. Meanwhile, each hit represents a waveform at a high sampling frequency (∼1 MHz). In order to capture the features of both the high-frequency waveforms and the temporal distribution of hits, Hit2Flux involves i) feature extraction by transforming AE hits into the frequency domain and organizing these spectra into sequences using a rolling window to form “sequences-of-sequences,” and ii) heat flux prediction using a long short-term memory (LSTM) network with sequences of sequences. The model is trained on AE hits recorded during pool boiling experiments using an AE sensor attached to the boiling chamber. Continuously sampled acoustic data using a hydrophone were also collected as a reference data set for this study. Results demonstrate that the proposed AE-based method achieves performance comparable to hydrophones, validating its potential for heat flux monitoring. Additionally, it is shown that the inclusion of multiple acoustic emission hits as model inputs leads to higher performance. The Hit2Flux model is also compared to methods pairing various signal preparation techniques with state-of-the-art models. This comparison further highlighted the superior accuracy of the proposed approach. The developed Hi2Flux algorithm can be applied to other transient sampling events, such as structural health monitoring, detection of electromagnetic pulses, among others. TechnicalInfo: # Data for: Hit2flux: A machine learning framework for boiling heat flux prediction using hit-based acoustic emission sensing Dataset DOI: [10.5061/dryad.g79cnp628](10.5061/dryad.g79cnp628) ## Description of the data and file structure This dataset includes acoustic emission hit data and waveforms, hydrophone data, pressure, and temperature data from transient pool boiling tests on copper microchannels. The pool boiling test facility includes (a) a heating element that consists of a copper block and cartridge heaters; (b) a closed chamber with flow loops for a chiller (Thermo Scientific Polar ACCEL 500 Low/EA) connecting Graham condenser (Ace glass 5953-106) with an adapter (Ace glass 5838-76) and an in-house built coiled copper condenser; and (c) a synchronized multimodal sensing system. The copper block is submerged in deionized water and heated by nine cartridge heaters (Omega Engineering HDC19102), each with a power rating of 50 W, inserted from the bottom. The cartridge heaters are connected to the DC power supply (MagnaPower SL200-7.5) for controlling the heating power. The copper tube coiled condenser is used to keep the vapor pressure in check during the boiling test. This is done by controlling the flow rate passing through it manually using the flow metering valve with a Vernier handle (Swagelok SS-SS4-VH). Two screw-plug immersion heaters (McMaster-Carr 4668T54) are immersed in the liquid pool for degassing and auxiliary heating. A variable-voltage transformer (McMaster-Carr 6994K17) is used for adjusting the voltage required for the immersion heaters within the given range. The test facility is installed on a Thorlab Nexus optical table (T46V) with passive legs (PTP703) for vibration isolation. The following sensors are installed in the pool boiling facility.  * A high-accuracy pressure transducer (Omega Engineering PX409030A5V) with an NI-9239 module is used to measure the vapor pressure in the boiling chamber. * Four T-type thermocouples (Omega Engineering Tj36-CPSS-032U-6) are inserted near the boiling surface of the copper block to measure the temperature gradient and calculate the heat flux and boiling surface temperature. Two T-type threaded thermocouples (McMaster-Carr 1245N16) are placed inside the boiling chamber to measure liquid and vapor temperatures. The thermocouples are connected to an NI-9210 module for data acquisition.  * Two hydrophones (High Tech HTI-96-Min) are immersed in the liquid pool for acoustic sensing. They are connected to an NI-9230 module. * An acoustic emission sensor (MISTRAS R3a) is mounted to the outer surface of the bottom plate of the boiling chamber. It is connected to a MISTRAS DAQ (1283 USB AE Node) for data collection.  The detailed experimental procedures can be found in [Pandey et al. 2024](https://www.sciencedirect.com/science/article/pii/S1359431123018367), [Pandey et al. 2024](https://www.sciencedirect.com/science/article/pii/S2352340924005493), and [Pandey et al. 2025](https://www.sciencedirect.com/science/article/pii/S1359431124029272). These data are used for training [SeqReg](https://github.com/cldunlap73/SeqReg), a machine learning framework for sequence regression. This dataset is used for acoustic-based heat flux prediction, detailed in this [tutorial](https://colab.research.google.com/drive/13TsHtLGvv9iiV82KZQYsbkmeTUubQO8c?usp=sharing).  ### Files and variables #### File: ned3-005\_Hit2Flux.zip **Description:** This zip includes four folders, i.e., Boiling-124a, Boiling-124b, Boiling-125, and Boiling-126. Each folder includes five files and a subfolder. In each folder, labeled as a generic test ID, Boiling-xxx, * The Boiling-xxx_AE.DTA file is the source file of acoustic emission signals captured using a MISTRAS R3a sensor and a MISTRAS USB AE Node. This file can be opened using the MISTRAS AEWin software.  * The Boiling-xxx_AEHit.txt file is the hit data exported from the DTA file. * The Boiling-xxx_AE_waveform folder contains the waveforms for each hit in csv format, also exported from the DTA file. * The Boiling-xxx_Hydrophone.lvm file includes the continuously sampled acoustic data using two HTI-96-MIN hydrophones with an NI-9230 module. * The Boiling-xxx_Temperature.lvm includes the temperature measurements using probe thermocouples (Omega Engineering Tj36-CPSS-032U-6) in the copper block and pool thermocouples in the water and vapor phases (McMaster-Carr 1245N16). These data are collected using an NI-9210 module. * The Boiling-xxx_Pressure.lvm file includes pressure measurements in the vapor phase using a pressure transducer (Omega Engineering PX409030A5V) and an NI-9239 module. Boiling-124a and Boiling-124b are closed chamber tests, where the Graham condenser is closed after degassing, and the pressure is regulated through the balance between boiling and condensation by tuning the flow rate of chiller water through the copper coil condenser. Boiling-125 and Boiling-126 are open-chamber tests, where the Graham condenser is open throughout the tests, and the vapor pressure inside the chamber is the same as the ambient pressure.  ## Code/software All files except for the DTA files can be opened using programming languages such as Python and MATLAB. They can also be opened using Excel, Notepad, or other sheet or text readers. Python users can follow the procedures documented in the tutorial of [SeqReg](https://github.com/cldunlap73/SeqReg) to read and use the dataset. The DTA file needs to be opened using the MISTRAS AEWin software, but it is not very often needed. For most analyses, the AEHit and waveforms are sufficient. The DTA file is provided in case users may want to export the hit data for different variables or in a different format. 
    more » « less
  2. Abstract: Two-phase cooling offers superior heat dissipation compared to conventional single-phase cooling methods. Nevertheless, the occurrence of critical heat flux (CHF) during boiling introduces reliability concerns, potentially leading to system failure. To improve system reliability, optical imaging is employed to analyze and monitor cooling systems without disrupting the boiling dynamics. These methods involve analyzing images of the boiling process to identify boiling regimes and evaluate heat flux. However, current optical-based methods are limited to static images, thereby missing out on the valuable temporal information captured by high-speed imaging. Inspired by the successful integration of temporal information in other fields, this work aims to exploit the temporal information from transient pool boiling captured via high-speed imaging for enhanced heat flux monitoring. For this purpose, two frameworks, comprising six different machine-learning models, have been developed for a comparative analysis. Specifically, the first framework includes two models that use static images for monitoring, serving as a representation of existing methodologies and a benchmark against which the second framework is measured. The remaining four models within the dynamic image-based framework (the 2nd framework) leverage sequences of images to capture temporal information. To evaluate the advantage of incorporating temporal information, transient boiling experiments were conducted to construct the dataset. A comparative analysis confirmed that temporal information significantly enhances the accuracy of the developed heat flux monitoring models. Among these models, the developed principal components (PCs)-convolutional neural network (CNN) stands out with a superior determination coefficient of 97.4% and a mean absolute percentage error of 7.0%, achieving an excellent balance between monitoring accuracy and computational efficiency. TechnicalInfo: # Data for: A temporal–spatial framework for efficient heat flux monitoring of transient boiling Dataset DOI: [10.5061/dryad.6m905qgc7](10.5061/dryad.6m905qgc7) ## Description of the data and file structure This dataset includes the temperature, acoustic (hydrophone), and videos of transient pool boiling tests of water on flat copper surfaces. The pool boiling test facility includes (a) a heating element that consists of a copper block and cartridge heaters; (b) a closed chamber with flow loops for a chiller (Thermo Scientific Polar ACCEL 500 Low/EA) connecting Graham condenser (Ace glass 5953-106) with an adapter (Ace glass 5838-76) and an in-house built coiled copper condenser; and (c) a synchronized multimodal sensing system. The copper block is submerged in deionized water and heated by nine cartridge heaters (Omega Engineering HDC19102), each with a power rating of 50 W, inserted from the bottom. The cartridge heaters are connected to the DC power supply (MagnaPower SL200-7.5) for controlling the heating power. The copper tube coiled condenser is used to keep the vapor pressure in check during the boiling test. This is done by controlling the flow rate passing through it manually using the flow metering valve with a Vernier handle (Swagelok SS-SS4-VH). Two screw-plug immersion heaters (McMaster-Carr 4668T54) are immersed in the liquid pool for degassing and auxiliary heating. A variable-voltage transformer (McMaster-Carr 6994K17) is used for adjusting the voltage required for the immersion heaters within the given range. The test facility is installed on a Thorlab Nexus optical table (T46V) with passive legs (PTP703) for vibration isolation. ### Files and variables #### File: ned3-006\_BoilingImageSequence.zip **Description:** This zip file includes eleven folders, i.e., Boiling-87, Boiling-89, Boiling-90, Boiling-91, Boiling-92, Boiling-93, Boiling-94, Boiling-96a, Boiling-96b, Boiling-96c, and Boiling-96d. Each folder, labeled with a test ID, Boiling-xxx, includes three files: * The Boiling-xxx_Temperature.lvm includes the temperature measurements using probe thermocouples (Omega Engineering Tj36-CPSS-032U-6) in the copper block and pool thermocouples in the water and vapor phases (McMaster-Carr 1245N16). These data are collected using an NI-9210 module. * The Boiling-xxx_Hydrophone.lvm file includes the continuously sampled acoustic data using two HTI-96-MIN hydrophones with an NI-9230 module. * The Boiling-xxx_video.mp4 file is a video for the boiling test. The original video (.cine) was captured using a Phantom VEO 710L high-speed camera. The .mp4 file was converted from the .cine file using the [Phantom Camera Control (PCC) software](https://www.phantomhighspeed.com/resourcesandsupport/phantomresources/pccsoftware). ## Code/software * The .txt and .lvm files can be opened and analyzed using programming languages such as Python and MATLAB. They can also be opened using Excel, Notepad, or other sheet or text readers. * The .mp4 file can be opened using a video player. 
    more » « less
  3. Abstract: Understanding thermal sensitivity of magnetic nuclei is an important step toward noninvasive thermometers in magnetic resonance imaging applications. This data set is associated with the exploration of a specific nucleus, 51V, and its associated temperature dependent spectroscopic properties in a series of four V(V) complexes: [VO(3-OEtHshed)(tbad)] (1, tbad = 5-(adamantan-1-yl)-3-(tert-butyl)benzene-1,2-diol, 3-OEtHshed = (E)-2-ethoxy-6-(((2-((2-hydroxyethyl)amino)ethyl)imino)methyl)phenol), [VO(3-OEtHshed)(cat)] (2, cat = catechol), [VO(3-OEtHshed)(2OHP)] (3, 2OHP = 2-(hydroxymethyl)phenol) and [VO2(3-OEtHshed)] (4). These data demonstrate an increasing thermal sensitivity for the 51V nuclear magnetic resonance signal when the supporting ligand enables a low-energy ligand-to-metal-charge-transfer transition. This is the first demonstration of any sort of design strategy to increase the thermal sensitivity of the 51V nucleus. Methods: Methods for analysis are described in detail in the manuscript and accompanying supplementary information available from the Royal Society of Chemistry at: http://dx.doi.org/10.1039/D6CC02350A Citation for manuscript: A. C. Bates, J. V. Grundy, J. R. Stapf, Ö. Üngör, D. C. Crans, J. M. Zadrozny; Ligand-to-Metal Charge Transfer Control of 51V NMR Thermal Sensitivity Chemical Communications, 2026, DOI: 10.1039/D6CC02350A TechnicalInfo: # Data from: Ligand-to-metal charge transfer control of ^51^V NMR thermal sensitivity Dataset DOI: [10.5061/dryad.3ffbg79zn](https://doi.org/10.5061/dryad.3ffbg79zn) ## Description of the data and file structure All contained data are either the raw data directly from the instruments used to acquire the data, or aggregated collections of the data in a format sufficient for plotting and analysis in external programs. The data that are attached are compressed, zip folders of the raw data and other data used to make figures for the manuscript. Unzip these folders to access the raw data. All contained data are either the raw data directly from the instruments used to acquire the data, or aggregated collections of the data in a format sufficient for plotting and analysis in external programs. Most of the data was processed using Excel and MestreNova, with OriginPro allowing for final production of manuscript figures. ### Files and variables ### File: UV-Vis_Spectra.zip This compressed folder has five different files in it. The UV-Vis summary Excel file "UV-Vis summary.xlsx" contains the final tabulated electronic absorption spectroscopy data for compounds 1-4 from the main manuscript. The data is saved as an Excel file. Data are organized in columns: wavelength (nm), absorbance (A), and molar absorptivity (epsilon) for each of the complexes, respectively. An additional column that converts the wavelength to wavenumbers is provided for convenience. The main manuscript contains the plot of epsilon versus wavenumber as Figure 3. See main manuscript for measurement conditions, used instrument, and other relevant experimental points. The other four files, labeled as "compound name 0.1mM.csv" are the raw instrumental outputs saved in comma-delimited files that can be opened via any text editor and Excel. These data were all collected at 0.1 mM concentration. These .csv files have all experimental data. Briefly, the block of text under "summary" contains instrumental summary information (spectrometer, model, software version, sample name); "parameter" has explicit instrumental collection conditions, e.g., the wavelength window, the slit width, the scanning speed; and below that are the actual data in two columns, one of wavelength, and one of absorbance. ### **File: Low-field_NMR.zip** This compressed file contains two folders that constitute the worked up ("processed") and raw ("unprocessed") low-field NMR spectra. In the unprocessed data folder, there are four subfolders labeled with the compound #s from the manuscript. Dragging one of these folders into MestreNova (see NMR program details below) will immediately open the results of the experiment. There are subfolders with instrumental parameters and a .jdx file, which is a standardized spectral formula (see NMR notes below). The processed data folder contains the worked-up data for each compound. They are saved as tab-delimited .csv files, each with two columns, ppm on the left and spectral intensity on the right. These can be opened in any graphing program. The folder also contains all of them collected into a single MNova file as well, which can be opened with MestreNova.  ### **File: RT_51V_NMR_spectra.zip** This compressed data set has the room-temperature ^51^V NMR spectra for complexes 1-4, which are depicted in Figure 3 in the main manuscript. This folder contains ten different files. There are four tab-delimited .csv files, one for each complex, which are the xy coordinates for the NMR spectra as depicted in Figure 3. These data are separated into two columns, left is chemical shift in ppm and the right one is the 51V NMR signal intensity. These data can be opened with any standard text edit/spreadsheet software. There are also five folders entitled, e.g., "Compound 1 25 dC". These folders contain the raw instrumental output from the NMR for each of the four compounds, all collected at 25 degrees Celsius. These folders can be dragged, in their entirety, into the program MestreNova (see notes below) and it will give an initial process of the corresponding NMR spectrum. The final file in this folder is "All compounds in MeCN at 25dC.mnova". This is the aggregate data set from the room temperature ^51^V NMR spectra, all collected in acetonitrile (MeCN) in a format that can be opened by MestreNova by simply dragging the file into the opened program window (see notes below about MestreNova and NMR processing).  ### File: 2D_NMRs.zip This compressed folder contains all of the 2-dimensional NMR spectra used to assign structure for complexes 1-4. In this folder are four compressed folders that contain relevant NMR spectra for the labeled compound. The folder for compound 1 contains the one-dimensional proton NMR spectra, labeled as 1H and 1H D2O spike for this complex. The files including COSY and NOESY in this folder correspond to the 2D spectra depicted in the manuscript SI file. The folder for compound 2 contains the one-dimensional 1H NMR spectrum (labeled as "1H") and the two-dimensional spectra are labeled with "COSY" and "NOESY". The folder for compound 3 contains the one-dimensional proton ("1H") and COSY and NOESY spectra. Compound 4 only contains the COSY and NOESY 1H spectra. For all folders, data is supplied as folders that can be opened with MestreNova (or other appropriate NMR software, see below) or the MestreNova files themselves. ### File: VT_NMR_data.zip The compressed folder with this data contains variable-temperature NMR spectra for all complexes and tabulated variable-temperature NMR linewidths discussed in the manuscript. All temperatures are in degrees C. There are four subfolders associated with this data set, which are labeled according to the complexes (1-4) which they correspond to. Within these subfolders, there are a set of subfolders labeled with the name of the complex, e.g., "VO(3OEtHSHED)(TBAD)" for complex 1 and then a number, ranging from 25 to 50. These folders are the solution phase NMR spectra for the complexes, and the number corresponds to the temperature of the experiment. Like with other NMR spectra collected here, these folders can be dragged into the MNova (or other) software for analysis. We have also collected the worked up variable temperature data for the compound into a single MNova file in each of these folders. Finally, there is an Excel spreadsheet that collects the temperature dependence of peak positions and their linewidths. This spreadsheet can be opened in Excel or other spreadsheet software. The data are organized in this spreadsheet by compound (1 to 4, from left to right). The solvent of measurement is listed under the name of the compound. The top rows of variable temperature data contain the chemical shift information. Below that, in the data sets marked, e.g., "Peak 4 (SW)" we have the signal linewidths in Hz and then the same values in ppm even further down. There is a "Dd/DT" row which is the thermal sensitivity of the chemical shift for the variable temperature data sets and then a "Resolution" row even further down which contains values of thermal sensitivity divided by the linewidth. ## Code/software Data that is recorded as .csv, .txt, or in other common spreadsheet extensions can be opened in Excel or other standard plotting software. The majority of our NMR data were analysed and processed using [MNova](https://mestrelab.com/main-product/mnova). MestreNova (or MNova) is a common NMR-processing software. Many universities have access to it by purchasing a license, and analysis of the data can be performed simply by dragging the FID files into the program. There are alternatives for analysis, e.g. [Topspin](https://www.bruker.com/en/products-and-solutions/mr/nmr-software/topspin.html). There are also free software packages available for analysis. MNova has [NMR Lite](https://mestrelab.com/download-nmr-lite), which is a cheaper version and can be used free for an extended period. The program [NUTS](https://www.aiinmr.com/NUTS-Program-Download) is also a free software package that is available from Anasazi Instruments. In some cases, NMR spectra are saved in the .jdx file type, which can be opened with many different spectral software, including the free [jspecview](https://jspecview.sourceforge.net/). See [here](https://opg.optica.org/as/abstract.cfm?uri=as-47-8-1093) for more details. ## Access information Other publicly accessible locations of the data: * Figures and some tabulated data are available in the SI of the manuscript at DOI: 10.1039/D6CC02350A Data was derived from the following sources: * N/A 
    more » « less
  4. Abstract: Flow boiling in microchannel heat sinks is promising for next-generation electronics cooling but it implementation is limited by the associated interfacial instabilities, flow oscillations, vapor choking, and local dryout. Existing diagnostics for two-phase flows primarily rely on optical visualization and temperature/pressure measurements, which lack the capability for real-time detection of transient flow events in compact or visually inaccessible systems. This work investigates the use of acoustic emission (AE) sensing as a nonintrusive diagnostic tool for identifying phase-change events and characterizing two-phase flow behavior in a microchannel heat sink. A multimodal experimental facility integrating synchronized acoustic emission sensing, microphone measurements, thermofluidic measurements, and optical imaging was developed for flow boiling experiments under controlled heating conditions. Representative experiments comparing single-phase flow and two-phase flow conditions demonstrate that the onset of boiling produces substantial increases in AE amplitude and AE hit rate. The results suggest that acoustic sensing can provide a sensitive indicator of bubble nucleation, vapor transport, and transient interfacial dynamics in confined boiling flows. The presented framework sets a foundation for future development of physics-informed acoustic diagnostics and machine-learning-assisted monitoring of two-phase thermal management systems. TechnicalInfo: # Data from: Acoustic signatures of two-phase flows in a microchannel heat sink Dataset DOI: [10.5061/dryad.kwh70rzm3](https://doi.org/10.5061/dryad.kwh70rzm3) ## Description of the data and file structure ##### ned-012_FlowBoilingAE.zip: This file includes four folders: DataAcquisition, MicrochannelHeatSinkCAD for design files of the microchannel heat sink and test section, and test data for a representative single-phase flow case (SinglePhase-01) and a representative two-phase flow case (TwoPhase-02). ###### DataAcquisition:  This folder includes an Arduino sketch file "Flow_Loop_Data_Collection.ino" for the acquisition of temperature, flow rate, and pressure drop data from the flow tests.  ###### MicrochannelHeatSinkCAD:  This folder includes the CAD model for the straight microchannel heat sink tested in this work. * MC - test section.V1.SLDPRT file is the CAD model of the straight microchannel heat sink used in the present work. * MC - test section.V1.STEP file is the CAD model of the straight microchannel heat sink used in the present work. ###### SinglePhase-01: This folder include six files for a representative single-phase flow test:  * Acoustic_singlephase_roomtemperature_01.DTA: Source file for AE sensing, generated by MISTRAS AEWin. * Acoustic_singlephase_roomtemperature_01.txt: AE hit file generated from the source file using MISTRAS AEWin. This file reports AE hit parameters, including time of the hit (s), AE amplitude (dB), AE rise (μs), AE count (dimensionless), AE energy (pVs), and AE duration (μs).  * Heater 5V 440mA inlet set 87C Pump 8V Test 1.txt: Temperature, flow rate, and pressure drop data recorded using Arduino, including date, time, flow rate (L/min), the fluid temperatures at the inlet and outlet of the test section (°C), pressure drop (psi), and the heater temperature (°C) at a power load of 2.2 W (voltage: 5V, current: 440 mA). * Microphone.lvm: LabVIEW measurement file recording microphone data (note that this file has flaws due to data requisition - it has time gaps where no data is registered). * Video_singlephase-01.mp4: Video file for the single-phase flow test. * multimodal_analysis_singlephase_v8.m: MATLAB code to analyze and plot the acoustic data.  ###### TwoPhase-04: This folder include six files for a representative single-phase flow test:  * Acoustic_twophase_roomtemperature_04.DTA: Source file for AE sensing, generated by MISTRAS AEWin. * Acoustic_twophase_roomtemperature_04.txt: AE hit file generated from the source file using MISTRAS AEWin. This file reports AE hit parameters, including time of the hit (s), AE amplitude (dB), AE rise (μs), AE count (dimensionless), AE energy (pVs), and AE duration (μs).  * Heater 25V 1810mA inlet set 87C Pump 8V Test 4.txt: Temperature (°C) data recorded using Arduino, including date, time, flow rate (L/min), the fluid temperatures at the inlet and outlet of the test section (°C), pressure drop (psi), and the heater temperature (°C) at a power load of 45.3 W (voltage: 25V, current: 1810 mA). * Microphone_04.lvm: LabVIEW measurement file recording microphone data (note that this file has flaws due to data requisition - it has time gaps where no data is registered). * Video_twophase_04.mp4: Video file for the two-phase flow test. * multimodal_analysis_twophase_v8.m: MATLAB code to analyze and plot the acoustic data.  ## Accessibility * The source files for AE sensing (.DTA) can be opened using MISTRAS AEWin software or MistrasDTA, an open-source package on GitHub ([https://github.com/d-cogswell/MistrasDTA](https://github.com/d-cogswell/MistrasDTA)). * The LabView measurement files (.lvm) can be opened using Notepad or pandas ([https://pandas.pydata.org/](https://pandas.pydata.org/)). * The Aduino sketch file (.ino) can be opened using a standard text editor (Notepad, Sublime Text, etc.), Arduino IDE, or VS Code.  - The SolidWorks CAD files can be opened using SolidWorks or Autodesk Viewer (free: [https://viewer.autodesk.com/](https://viewer.autodesk.com/)). - The .STEP CAD files can be opened using FreeCAD ([https://www.freecad.org/](https://www.freecad.org/)) or online STEP viewers such as [https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/](https://mantle3d.com/free-online-step-and-stl-cad-file-viewer-no-downloads-needed/) and [https://imagetostl.com/view-stp-online](https://imagetostl.com/view-stp-online) 
    more » « less
  5. {"Abstract":[" \n\nThis submission provides all the data and R code necessary to 1) generate the species distribution estimates and phenological predictions underlying all analyses, and 2) all results presented in the main text of the manuscript titled "Shifts in phenology and species ranges synergistically alter the timing and species composition of the flowering season" (Ramirez-Parada, Park, Peng, Nishino, Kartesz, Record, Davis, and Mazer, 2025). A preprint of this work can be accessed at: https://doi.org/10.32942/X28W5Z . This work was published in Global Change Biology (DOI: https://doi.org/10.1002/ecs2.70070).\n\nIn order for the code to work, users need to preserve the folder structure of the code and data, as the R Markdown files in the "Code" folder have relative file paths that read and write files within the "Data" folder and subfolders therein. These two folders are placed at the same level (i.e., they should both be stored within the same folder). Moving either will require re-writing the filepaths across Rmds.\n\nFor detailed descriptions of all materials (code and data) and instructions for using them, please refer to the "READ ME.md" file within "Project folder" and the main text of the manuscript.Note: This version corrects an error in  the .csv files containing the performance metrics for the three types of SDM fit for each species in the data (described in the main text). The previous version erroneously contained the performance metrics for the same model type across all three .csv files.\n\n "]} 
    more » « less