Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 11:00 PM ET on Thursday, November 12th until 12:00 AM ET on Friday, November 13th due to maintenance. We apologize for the inconvenience.


This content will become publicly available on November 11, 2027

Title: Ensemble Logic for Symbolic Representation of Sleep Medicine Guidelines
The American Academy of Sleep Medicine (AASM) Manual is the clinical standard for polysomnography (PSG) scor-ing, but its narrative rules can admit multiple reasonable interpretations, contributing to inter-scorer variability and implementation differences across studies and software systems. We present a formal framework for translating sleep-scoring rules into Rational Ensemble Logic (QEL), a dense-time (i.e., a continuous, rational-valued timeline rather than discrete steps) formalism that combines first-order quantification with metric temporal operators. Using an extraction-and-compilation procedure, we identified 18 unique atomic propositions and derived 12 final specifica-tions corresponding to clinically scoreable AASM events. Back-translation of QEL specifications into clinician-facing language retained high semantic fidelity to the original scoring narratives (embedding cosine similarity: 79.3, 95% CI: 79.0–79.7) despite low lexical overlap (ROUGE-L: 18.3, 95% CI: 17.6–18.9). Formalization also clarifies latent ambiguities, including implicit physiological latencies and overlapping exclusions. This framework yields executable, rigorous rule specifications for computational phenotyping, more consistent implementation across datasets, and stan-dardized open-source PSG analysis.  more » « less
Award ID(s):
2500624
PAR ID:
10717224
Author(s) / Creator(s):
; ; ; ; ;
Publisher / Repository:
Annual Proceedings of the American Medical Informatics Association, 2026.
Date Published:
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. Study objectivesEvaluate the performance of a novel home sleep apnea test with embedded ECG (SANSA, Huxley Medical, Inc.) in the diagnosis of obstructive sleep apnea (OSA). MethodsThis prospective multicenter validation study included 340 participants who underwent simultaneous polysomnography (PSG) and SANSA recordings across 7 clinical sites. Participants were diverse across age, sex, race, skin tone, and body mass index. Diagnostic performance was assessed with the apnea-hypopnea index (AHI) using both Rule 1A and Rule 1B across standard cutoffs for mild, moderate, or severe (≥5 events/h), moderate-to-severe (≥15 events/h), and severe (≥30 events/h) OSA. The agreement for AHI and total sleep time (TST) between SANSA and consensus PSG scores from three independent scorers was evaluated using Pearson’s correlation and Bland–Altman analysis. Sensitivity and specificity were calculated at each OSA severity level. Performance of participating site PSG scores were also evaluated against consensus PSG scores for comparison. ResultsSANSA demonstrated excellent agreement with PSG for most performance parameters. AHI correlation was 0.91 (95% CI: 0.89, 0.93) using Rule 1B and 0.90 (95% CI: 0.87, 0.92) using Rule 1A. Compared to consensus scored PSG, the device detected moderate-to-severe OSA using Rule 1B (the primary endpoint) with a sensitivity of 88% (95% CI: 81, 93%) and specificity of 87% (95% CI: 82, 91%), while site PSG sensitivity was 89% (95% CI: 82, 94%) and specificity was 93% (95% CI: 88, 96%). SANSA TST highly correlated with PSG TST (R = 0.82, 95% CI: 0.78, 0.85) and classified sleep epochs with an accuracy of 87.2% (95% CI: 87.0, 87.5%). ConclusionThe SANSA home sleep apnea test demonstrated robust diagnostic performance for OSA detection including measurement of sleep compared to PSG. Its patch morphology and embedded ECG confer ease of use and multi-diagnostic potential in sleep medicine and cardiology for the detection of OSA and cardiac arrhythmias across diverse clinical populations. Clinical trial registration[https://www.clinicaltrials.gov/study/NCT06070389], identifier [NCT06070389] 
    more » « less
  2. Abstract Study Objective We investigated sleep disparities and academic achievement in college. Methods Participants were 6,002 first-year college students attending a midsize private university in the southern United States [62.0% female, 18.8% first-generation, 37.4% Black, Indigenous, or People of Color (BIPOC) students]. During the first 3–5 weeks of college, students reported their typical weekday sleep duration, which we classified as short sleep (<7 hours), normal sleep (7–9 hours), or long sleep (>9 hours). Results The odds for short sleep were significantly greater in BIPOC students (95% CI: 1.34–1.66) and female students (95% CI: 1.09–1.35), and the odds for long sleep were greater in BIPOC students (95% CI: 1.38–3.08) and first-generation students (95% CI: 1.04–2.53). In adjusted models, financial burden, employment, stress, STEM academic major, student athlete status, and younger age explained unique variance in sleep duration, fully mediating disparities for females and first-generation students (but only partially mediating disparities for BIPOC students). Short and long sleep predicted worse GPA across students’ first year in college, even after controlling for high school academic index, demographics, and psychosocial variables. Conclusions Higher education should address sleep health early in college to help remove barriers to success and reduce disparities. 
    more » « less
  3. Wearable devices have become commonplace tools for tracking behavioral and physiological parameters in real-world settings. Nonetheless, the practical utility of these data for clinical and research applications, such as sleep analysis, is hindered by their noisy, large-scale, and multidimensional characteristics. Here, we develop a neural network algorithm that predicts sleep stages by tracking topological features (TFs) of wearable data and model-driven clock proxies (CPs) reflecting the circadian propensity for sleep. To evaluate its accuracy, we apply it to motion and heart rate data from the Apple Watch worn by young subjects undergoing polysomnography (PSG) and compare the predicted sleep stages with the corresponding ground truth PSG records. The neural network that includes TFs and CPs along with raw wearable data as inputs shows improved performance in classifying Wake/REM/NREM sleep. For example, it shows significant improvements in identifying REM and NREM sleep (AUROC/AUPRC improvements >13% and REM/NREM accuracy improvement of 12%) compared with the neural network using only raw data inputs. We find that this improvement is mainly attributed to the heart rate TFs. To further validate our algorithm on a different population, we test it on elderly subjects from the Multi-ethnic Study of Atherosclerosis cohort. This confirms that TFs and CPs contribute to the improvements in Wake/REM/NREM classification. We next compare the performance of our algorithm with previous state-of-the-art wearable-based sleep scoring algorithms and find that our algorithm outperforms them within and across different populations. This study demonstrates the benefits of combining topological data analysis and mathematical modeling to extract hidden inputs of neural networks from puzzling wearable data. 
    more » « less
  4. null (Ed.)
    Abstract Study Objectives The usage of wrist-worn wearables to detect sleep–wake states remains a formidable challenge, particularly among individuals with disordered sleep. We developed a novel and unbiased data-driven method for the detection of sleep–wake and compared its performance with the well-established Oakley algorithm (OA) relative to polysomnography (PSG) in elderly men with disordered sleep. Methods Overnight in-lab PSG from 102 participants was compared with accelerometry and photoplethysmography simultaneously collected with a wearable device (Empatica E4). A binary segmentation algorithm was used to detect change points in these signals. A model that estimates sleep or wake states given the changes in these signals was established (change point decoder, CPD). The CPD’s performance was compared with the performance of the OA in relation to PSG. Results On the testing set, OA provided sleep accuracy of 0.85, wake accuracy of 0.54, AUC of 0.67, and Kappa of 0.39. Comparable values for CPD were 0.70, 0.74, 0.78, and 0.40. The CPD method had sleep onset latency error of −22.9 min, sleep efficiency error of 2.09%, and underestimated the number of sleep–wake transitions with an error of 64.4. The OA method’s performance was 28.6 min, −0.03%, and −17.2, respectively. Conclusions The CPD aggregates information from both cardiac and motion signals for state determination as well as the cross-dimensional influences from these domains. Therefore, CPD classification achieved balanced performance and higher AUC, despite underestimating sleep–wake transitions. The CPD could be used as an alternate framework to investigate sleep–wake dynamics within the conventional time frame of 30-s epochs. 
    more » « less
  5. Sleep monitoring is essential for assessing overall health and managing sleep disorders, yet clinical adoption of consumer wearables remains limited due to inconsistent performance and scarce open source datasets and transparent codebase. In this study, we introduce WatchSleepNet, a novel, open-source three-stage sleep staging algorithm. The model uses sequence-to-sequence architecture integrating Residual Networks (ResNet), Temporal Convolutional Networks (TCN), and Long Short-Term Memory (LSTM) networks with self-attention to effectively capture both spatial and temporal dependencies crucial for sleep staging. To address the limited availability of high-quality wearable photoplethysmography (PPG) datasets, WatchSleepNet leveraged inter-beat interval (IBI) signals as a shared representation across polysomnography (PSG) and photoplethysmography (PPG) modalities. By pretraining on large PSG datasets and fine-tuning on wrist-worn PPG signals, the model achieved a REM F1 score of 0.631 ± 0.046 and a Cohen’s Kappa of 0.554 ± 0.027, surpassing previous state-of-the-art methods. To promote transparency and further research, we publicly release our model and codebase, advancing reproducibility and accessibility in wearable sleep research and enabling the development for more robust, clinically viable sleep monitoring solutions. 
    more » « less