Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 5:00 PM ET until 8:00 PM ET on Friday, September 11 due to maintenance. We apologize for the inconvenience.


Search for: All records

Creators/Authors contains: "Abdulmojeed, Mustapha"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Free, publicly-accessible full text available December 9, 2026
  2. Abstract It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1‐13C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio‐frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22‐fold (to 1,670) via parametric pumping. This active‐feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T2* of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated. 
    more » « less
  3. SABRE-SHEATH hyperpolarized15N2-imidazole is introduced as a novel15N NMR probe for Zn2+sensing. The method achieves 45 700 fold signal enhancement and a detection limit of 1.3 mM, enabling chemical sensing without penetration-depth limitations. 
    more » « less
  4. Abstract Hyperpolarized (HP) MRI using [1–13C]pyruvate is emerging as a promising molecular imaging approach. Among hyperpolarization methods, Signal Amplification By Reversible Exchange (SABRE) is attractive because SABRE polarizes the substrates directly in room‐temperature solutions avoiding complex hardware. Most SABRE experiments have historically been performed in methanol, a relatively toxic and difficult‐to‐remove solvent. Here we demonstrate the use of a 80/20 acetone/water (A/W) solvent system (Ace‐SABRE) to provide hyperpolarized [1–13C]pyruvate with up to 17% polarization, then implement a solvent processing protocol to achieve injectable solutions retaining 74% of the initial polarization, and lastly we demonstrate HP in vivo spectroscopy and imaging using the Ace‐SABRE platform to showcase metabolic tracking in a hepatocellular carcinoma (HCC) tumor as well as HP‐MRI, both in direct comparison to dissolution dynamic nuclear polarization (d‐DNP) experiments. The Ace‐SABRE technique promises faster adoption of SABRE hyperpolarization in biological experiments, overall lowering the barriers to entry for HP‐NMR and HP‐MRI. 
    more » « less