skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Bismuth, Jean"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. null (Ed.)
  2. null (Ed.)
    Abstract Endovascular navigation proficiency requires a significant amount of manual dexterity from surgeons. Objective performance measures derived from endovascular tool tip kinematics have been shown to correlate with expertise; however, such metrics have not yet been used during training as a basis for real-time performance feedback. This paper evaluates a set of velocity-based performance measures derived from guidewire motion to determine their suitability for online performance evaluation and feedback. We evaluated the endovascular navigation skill of 75 participants using three metrics (spectral arc length, average velocity, and idle time) as they steered tools to anatomical targets using a virtual reality simulator. First, we examined the effect of navigation task and experience level on performance and found that novice performance was significantly different from intermediate and expert performance. Then we computed correlations between measures calculated online and spectral arc length, our "gold standard" metric, calculated offline (at the end of the trial, using data from the entire trial). Our results suggest that average velocity and idle time calculated online are strongly and consistently correlated with spectral arc length computed offline, which was not the case when comparing spectral arc length computed online and offline. Average velocity and idle time, both time-domain based performance measures, are therefore more suitable measures than spectral arc length, a frequency-domain based metric, to use as the basis of online performance feedback. Future work is needed to determine how to best provide real-time performance feedback to endovascular surgery trainees based on these metrics. 
    more » « less
  3. null (Ed.)