Attention:The NSF Public Access Repository (PAR) system and access will be unavailable from 11:00 PM ET on Thursday, November 12th until 12:00 AM ET on Friday, November 13th due to maintenance. We apologize for the inconvenience.


Search for: All records

Creators/Authors contains: "Bright, Victor M"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Functional imaging in freely moving animals with genetically encoded voltage indicators (GEVIs) will open new capabilities for neuroscientists to study the behavioral relevance of neural activity with high spatial and temporal precision. However, miniaturization of an imaging system with sufficient collection efficiency to resolve the small changes in fluorescence yield from voltage spikes, as well as the development of efficient image sensors that are sufficiently fast to capture them, has proven challenging. We present a miniaturized microscope designed for voltage imaging, with a numerical aperture of 0.6, a 250 µm field of view, and a 1.3-1.6 mm working distance that weighs 16.4 g. We show it is capable of imagingin vivovoltage spikes from Voltron2 with a spike peak-to-noise ratio >3 at a framerate of 530 Hz. 
    more » « less
    Free, publicly-accessible full text available January 1, 2027
  2. Free, publicly-accessible full text available January 25, 2027
  3. We demonstrate a sub-millimeter-scale electrowetting prism array with individually addressable conical cavities fabricated using standard 2D lithography. The device achieves symmetric∼ ±8° beam steering through voltage-induced meniscus tilt in a compact transmissive platform. 
    more » « less
  4. In-situ monitoring techniques of reverse osmosis (RO) desalination systems, particularly those with chemical sensing capabilities, can provide the means for better understanding important scaling mechanisms as well as early scaling detection. In this work, both calcium sulfate and calcium carbonate scaling on RO membranes were detected concurrently in real time using Raman spectroscopy to provide a unique chemical fingerprint. Two different sampling methodologies (manual and automated) were employed, and their performance was evaluated by comparing the Raman detection times to concurrent values of flux decline. The manual sampling strategy resulted in the detection of calcium sulfate and calcium carbonate at mean permeate flux declines of 13 ± 10 % and 22 ± 3 %, respectively. The automated sampling strategy provided better performance, with detection of calcium sulfate and calcium carbonate at mean flux declines of 8 ± 5 % and 4 ± 3 %, respectively. The increasedsensitivity and decreased variability of the automated sampling strategy provided valuable preliminary insights for the selection of optimized sampling strategies. The ability to identify the chemical composition of different scaling crystals including their polymorphs is an important step toward better understanding of the crystallization pathways of multi-component feed streams used in seawater and brackish water RO desalination. 
    more » « less
  5. Miniaturized microscopes for monitoring neural activity are an indispensable tool for neuroscience research. We present a novel MEMS based miniature microscope with patterned optogenetic stimulation capabilities enabling cell-specific 2-photon optogenetics and 2-photon imaging. 
    more » « less
  6. High-speed widefield fluorescence imaging of neural activity in vivo is fundamentally limited by fluctuations in recorded signal due to background contamination and stochastic noise. In this study, we show background and shot noise-reduced imaging of the ultrafast genetically encoded Ca2+indicator GCaMP8f in CA1 pyramidal neurons using periodic structured illumination (SI) with computational image reconstruction. We implement what we believe to be a novel reconstruction method for data acquired using periodic structured illumination, termed pseudo-HiLo (pHiLo), that combines a pseudo-widefield (pWF) reconstruction with individual SI frames to perform a HiLo reconstruction. We compare this new technique to interleaved optical sectioning structured illumination microscopy (OS-SIM) and pWF reconstruction. We quantify the performance of each reconstruction by evaluating contrast, transient peak-to-noise ratio (PNR), pairwise correlation coefficients between ΔF/F time courses extracted from individual in-focus cells, and correlation coefficients between each cell with surrounding cell-free background pixels. We additionally incorporate a self-supervised deep learning method for real-time noise suppression (DeepCAD-RT) into our data preprocessing pipeline. At 500 Hz frame rates, we demonstrate a 75% increase in PNR using the denoised pHiLo reconstruction compared to pWF. Utilizing DeepCAD-RT, we show significant PNR improvements using both structured illumination (SI) reconstruction methods with OS-SIM showing a 59% increase in PNR after denoising. Both pHiLo and OS-SIM reconstructions result in a ≈65% decrease in the mean correlation coefficient of the ΔF/F time courses between ROIs in comparison with pWF, indicating the potential to remove background fluorescent transients from out-of-focus cells. 
    more » « less
  7. We discuss optical sectioning structured illumination microscopy (OS-SIM) for functional GCaMP8f imaging in the CA1 hippocampal region of awake mice. We demonstrate OS-SIM implementation to reduce out-of-focus signal contamination in recordings taken at 200 Hz. 
    more » « less
  8. We demonstrate a method that permits wavefront aberration correction using an array of electrowetting prisms. A fixed high fill factor microlens array followed by a lower fill factor adaptive electrowetting prism array is used to correct wavefront aberration. The design and simulation of such aberration correction mechanism is described. Our results show significant improvement to the Strehl ratio by using our aberration correction scheme which results in diffraction limited performance. Compactness and effectiveness of our design can be implemented in many applications that require aberration correction, such as microscopy and consumer electronics. 
    more » « less
  9. We demonstrate a novel electrowetting liquid combination using a room temperature ionic liquid (RTIL) and a nonpolar liquid, 1-phenyl-1-cyclohexene (PCH) suitable for focus-tunable 3-photon microscopy. We show that both liquids have over 90% transmission at 1300 nm over a 1.1 mm pathlength and an index of refraction contrast of 0.123. A lens using these liquids can be tuned from a contact angle of 133 to 48° with applied voltages of 0 and 60 V, respectively. Finally, a three-photon imaging system including an RTIL electrowetting lens was used to image a mouse brain slice. Axial scans taken with an electrowetting lens show excellent agreement with images acquired using a mechanically scanned objective. 
    more » « less
  10. Electrowetting-based adaptive optics are of great interest for applications ranging from confocal microscopy to LIDAR, but the impact of low-frequency mechanical vibration on these devices remains to be studied. We present a simple theoretical model for predicting the resonance modes induced on the liquid interface in conjunction with a numerical simulation. We experimentally confirm the resonance frequencies by contact angle modulation. They are found to be in excellent agreement with the roots of the zero-order Bessel functions of the first kind. Next, we experimentally verify that external axial vibration of an electrowetting lens filled with density mismatched liquids (Δρ = 250 kg/m3) will exhibit observable Bessel modes on the liquid–liquid interface. An electrowetting lens filled with density matched liquids (Δρ = 4 kg/m3) is robust to external axial vibration and is shown to be useful in mitigating the effect of vibrations in an optical system. 
    more » « less