Search for: All records

Creators/Authors contains: "Calvez, Steven"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. A<sc>bstract</sc> Neutrino detectors are among the largest photon detection instruments, built to capture scarce photons upon energy deposition. Many discoveries in neutrino physics, including the neutrino itself, are inseparable from the advances in photon detection technology, particularly in photo-sensors and readout electronics, to yield ever higher precision and richer detection information. The measurement of the energy of neutrinos, referred to ascalorimetry, can be achieved in two distinct approaches: photon-counting, where single-photon can be counted digitally, and photon-integration, where multi-photons are aggregated and estimated via analogue signals. The energy is pursued today to reach permille level systematics control precision in ever-vast volumes, exemplified by experiments like JUNO. The unprecedented precision brings to the foreground the systematics due to calorimetric response entanglements in energy, position and time that were negligible in the past, thus driving further innovation in calorimetry. This publication describes a novel articulation that detectors can be endowed with multiple photon detection systems. Thismulti-calorimetryapproach opens the notion ofdual-calorimetrydetector, consisting of both photon-counting and photon-integration systems, as a cost-effective evolution from thesingle-calorimetrysetups used over several decades for most experiments so far. The dual-calorimetry design exploits unique response synergies between photon-counting and photon-integration systems, including correlations and cancellations in calorimetric responses, to maximise the mitigation of response entanglements, thereby yielding permille-level high-precision calorimetry. 
    more » « less
  2. The Jiangmen Underground Neutrino Observatory (JUNO) in southern China is designed to study neutrinos from nuclear reactors and natural sources to address fundamental questions in neutrino physics. Achieving its goals requires continuous operation over a 20-year period. The small photomultiplier tube (small PMT or SPMT) system is a subsystem within the experiment composed of 25,600 3-inch PMTs and their associated readout electronics. The High Voltage Splitter (HVS) is the first board on the readout chain of the SPMT system and services the PMTs by providing high voltage for biasing and by decoupling the generated physics signal from the high-voltage bias for readout, which is then fed to the front-end board. The necessity to handle high voltage, manage a large channel count, and operate stably for 20 years imposes significant constraints on the physical design of the HVS. This paper serves as a comprehensive documentation of the HVS board: its role in the SPMT readout system, the challenges in its design, performance and reliability metrics, and the methods employed for production and quality control. 
    more » « less
    Free, publicly-accessible full text available February 1, 2027
  3. Free, publicly-accessible full text available June 1, 2027
  4. Neutrino oscillations, a quantum effect manifesting at macroscopic scales, are governed by lepton flavor mixing angles and neutrino mass-squared differences that are fundamental parameters of particle physics, representing phenomena beyond the Standard Model. Precision measurements of these parameters are essential for testing the completeness of the three-flavor framework, determining the mass ordering of neutrinos, and probing possible new physics. The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton liquid-scintillator detector located 52.5 km from multiple reactor cores, designed to resolve the interference pattern of reactor neutrinos with sub-percent precision. Here we report, using the first 59.1 days of data collected since detector completion in August 2025, the first simultaneous high-precision determination of two neutrino oscillation parameters, sin²θ₁₂ = 0.3092 ± 0.0087 and Δm²₂₁ = (7.50 ± 0.12) × 10⁻⁵ eV² for the normal mass ordering scenario, improving the precision by a factor of 1.6 relative to the combination of all previous measurements. These results advance the basic understanding of neutrinos, validate the detector's design, and confirm JUNO's readiness for its primary goal of resolving the neutrino mass ordering with a larger dataset. The rapid achievement with a short exposure highlights JUNO's potential to push the frontiers of precision neutrino physics and paves the way for its broad scientific program. 
    more » « less
    Free, publicly-accessible full text available June 11, 2027
  5. Abstract The Jiangmen Underground Neutrino Observatory (JUNO) started physics data taking on 26 August 2025. JUNO consists of a 20-kton liquid scintillator central detector, surrounded by a 35 kton water pool serving as a Cherenkov veto, and almost 1000 m2of plastic scintillator veto on top. The detector is located in a shallow underground laboratory with an overburden of 1800 m.w.e. This paper presents the performance results of the detector, extensively studied during the commissioning of the water phase, the subsequent liquid scintillator filling phase, and the first physics runs. The liquid scintillator achieved an attenuation length of 20.6 m at 430 nm, while the high coverage PMT system and scintillator together yielded about 1785 photoelectrons per MeV of energy deposit at the detector centre, measured using the 2.223 MeVγfrom neutron captures on hydrogen with an Am-C calibration source. The reconstructed energy resolution is 3.4% for two 0.511 MeVγat the detector centre and 2.9% for the 0.93 MeV quenched214Po alpha decays from natural radioactive sources. The energy non-linearity is calibrated to better than 1%. Intrinsic contaminations of238U and232Th in the liquid scintillator are below 10-16g/g, assuming secular equilibrium. The water Cherenkov detector achieves a muon detection efficiency better than 99.9% for muons traversing the liquid scintillator volume. During the initial science runs, the data acquisition duty cycle exceeded 97.8%, demonstrating the excellent stability and readiness of JUNO for high-precision neutrino physics. 
    more » « less
    Free, publicly-accessible full text available April 1, 2027
  6. Abstract Large-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ($$\alpha ,\,n$$ α,n ) reactions. In organic liquid scintillator detectors,$$\alpha $$ α particles emitted from intrinsic contaminants such as$$^{238}$$ 238 U,$$^{232}$$ 232 Th, and$$^{210}$$ 210 Pb/$$^{210}$$ 210 Po, can be captured on$$^{13}$$ 13 C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ($$\alpha ,\,n$$ α,n ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable$$^{13}$$ 13 C$$(\alpha ,\,n)^{16}$$ (α,n) 16 O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors. 
    more » « less
  7. Abstract We explore the decay of bound neutrons in the JUNO liquid scintillator detector into invisible particles (e.g.,$$n\rightarrow 3 \nu $$ n→3ν or$$nn \rightarrow 2 \nu $$ nn→2ν ), which do not produce an observable signal. The invisible decay includes two decay modes:$$ n \rightarrow { inv} $$ n→inv and$$ nn \rightarrow { inv} $$ nn→inv . The invisible decays ofs-shell neutrons in$$^{12}\textrm{C}$$ 12 C will leave a highly excited residual nucleus. Subsequently, some de-excitation modes of the excited residual nuclei can produce a time- and space-correlated triple coincidence signal in the JUNO detector. Based on a full Monte Carlo simulation informed with the latest available data, we estimate all backgrounds, including inverse beta decay events of the reactor antineutrino$${\bar{\nu }}_e$$ ν¯ e , natural radioactivity, cosmogenic isotopes and neutral current interactions of atmospheric neutrinos. Pulse shape discrimination and multivariate analysis techniques are employed to further suppress backgrounds. With two years of exposure, JUNO is expected to give an order of magnitude improvement compared to the current best limits. After 10 years of data taking, the JUNO expected sensitivities at a 90% confidence level are$$\tau /B( n \rightarrow { inv} ) > 5.0 \times 10^{31} \, \textrm{years}$$ τ/B (n→inv) >5.0×1031years and$$\tau /B( nn \rightarrow { inv} ) > 1.4 \times 10^{32} \, \textrm{years}$$ τ/B (nn→inv) >1.4×1032years . 
    more » « less
  8. Abstract This paper presents an energy resolution study of the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3% at 1 MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of the liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The results of this study reveal an energy resolution of 2.95% at 1 MeV. Furthermore, this study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data collection. Moreover, it provides a guideline for comprehending the energy resolution characteristics of liquid scintillator-based detectors. 
    more » « less