skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Search for: All records

Creators/Authors contains: "Cogan, Gregory B"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract ObjectiveEffective surgical treatment of drug‐resistant epilepsy depends on accurate localization of the epileptogenic zone (EZ). High‐frequency oscillations (HFOs) are potential biomarkers of the EZ. Previous research has shown that HFOs often occur within submillimeter areas of brain tissue and that the coarse spatial sampling of clinical intracranial electrode arrays may limit the accurate capture of HFO activity. In this study, we sought to characterize microscale HFO activity captured on thin, flexible microelectrocorticographic (μECoG) arrays, which provide high spatial resolution over large cortical surface areas. MethodsWe used novel liquid crystal polymer thin‐film μECoG arrays (.76–1.72‐mm intercontact spacing) to capture HFOs in eight intraoperative recordings from seven patients with epilepsy. We identified ripple (80–250 Hz) and fast ripple (250–600 Hz) HFOs using a common energy thresholding detection algorithm along with two stages of artifact rejection. We visualized microscale subregions of HFO activity using spatial maps of HFO rate, signal‐to‐noise ratio, and mean peak frequency. We quantified the spatial extent of HFO events by measuring covariance between detected HFOs and surrounding activity. We also compared HFO detection rates on microcontacts to simulated macrocontacts by spatially averaging data. ResultsWe found visually delineable subregions of elevated HFO activity within each μECoG recording. Forty‐seven percent of HFOs occurred on single 200‐μm‐diameter recording contacts, with minimal high‐frequency activity on surrounding contacts. Other HFO events occurred across multiple contacts simultaneously, with covarying activity most often limited to a .95‐mm radius. Through spatial averaging, we estimated that macrocontacts with 2–3‐mm diameter would only capture 44% of the HFOs detected in our μECoG recordings. SignificanceThese results demonstrate that thin‐film microcontact surface arrays with both highresolution and large coverage accurately capture microscale HFO activity and may improve the utility of HFOs to localize the EZ for treatment of drug‐resistant epilepsy. 
    more » « less