Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c2) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.more » « lessFree, publicly-accessible full text available March 1, 2027
-
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4 keV showed sensitivity to ∼20 keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1 keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10−6 set at 0.50 keV, the lowest thermodynamic threshold explored.more » « less
-
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to O(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF3I and C3F8. The CF3I run consisted of 36.8 kg of CF3I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C3F8 runs consisted of 52 kg of C3F8 reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF3I bubble chamber used iodine as the target material.more » « less
-
We present the measurement of -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of -argon secondary interactions within the liquid argon. This is the first measurement of -argon absorption at this kinetic energy range as well as the first ever measurement of -argon charge exchange.more » « lessFree, publicly-accessible full text available June 1, 2027
-
The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.more » « lessFree, publicly-accessible full text available March 1, 2027
-
The Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment with a rich physics program that includes searches for the hypothetical phenomenon of proton decay. Utilizing liquid-argon time-projection chamber technology, DUNE is expected to achieve world-leading sensitivity in the proton decay channels that involve charged kaons in their final states. The first DUNE demonstrator, ProtoDUNE Single-Phase, was a 0.77 kt detector that operated from 2018 to 2020 at the CERN Neutrino Platform, exposed to a mixed hadron and electron test-beam with momenta ranging from 0.3 to . We present a selection of low-energy kaons among the secondary particles produced in hadronic reactions, using data from the 6 and beam runs. The selection efficiency is 1% and the sample purity 92%. The initial energies of the selected kaon candidates encompass the expected energy range of kaons originating from proton decay events in DUNE (below ). In addition, we demonstrate the capability of this detector technology to discriminate between kaons and other particles such as protons and muons, and provide a comprehensive description of their energy loss in liquid argon, which shows good agreement with the simulation. These results pave the way for future proton decay searches at DUNE.more » « lessFree, publicly-accessible full text available March 1, 2027
An official website of the United States government
