Search for: All records

Creators/Authors contains: "Cui, Jingbiao"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Free, publicly-accessible full text available March 13, 2027
  2. We investigate the effects of electron beam energy on defect formation in monolayer graphene using Raman spectroscopy and the local activation model. Monolayer graphene samples were irradiated at beam energies ranging from 1 to 30 keV, and the evolution of Raman D, G, and D’ peaks was monitored as a function of electron fluence. For all energies, the ID/IG and ID′/IG ratios exhibited a two-stage behavior, initially increasing with fluence before decreasing at higher defect densities, consistent with the local activation model predictions. Notably, the maximum ID/IG ratio decreased and shifted to a higher fluence with increasing beam energy. At lower beam energies (1–2 keV), an additional broad Raman peak was observed near the G peak, attributed to carbonaceous film deposition from secondary electrons (SEs). Defect formation was modeled using the local activation model with adjustments to account for SE-induced dissociation of surface adsorbates, showing good agreement with experimental data. Parameters A and B, which represent the incident electron fluence required to generate a defect-active region and the fraction of dissociable adsorbates, respectively, showed systematic trends with beam energy. Postirradiation annealing studies were conducted to determine activation energies for defect healing via Arrhenius analysis. The extracted activation energies (0.31–0.48 eV) are consistent with sp3-type defects such as hydrogen and hydroxyl groups with attached water molecules. These findings highlight the critical role of beam energy and SE yield in the defect engineering of graphene and demonstrate the utility of the local activation model in quantitatively describing beam-induced disorder. 
    more » « less
    Free, publicly-accessible full text available March 1, 2027
  3. Free, publicly-accessible full text available December 26, 2026
  4. We study the effects of electron irradiation on suspended graphene monolayers and graphene supported on SiO2 substrates in the range 5.0 × 1015–4.3 × 1017 electrons/cm2. The suspended graphene monolayers are exfoliated over SiO2 substrates containing micrometer-sized holes, with graphene completely covering the hole, and are referred to as graphene drums. The irradiation was performed using a scanning electron microscope at 20–25 keV electron energy. We observe a two-stage behavior for the ID/IG, ID′/IG, and ID/ID′ ratios as a function of the average distance between defects, LD, where ID, IG, and ID′ are the intensities of the Raman D, G, and D′ peaks, respectively. Good fits to the dependence of the ratios on LD are obtained using the local activation model equation. The fits are used to characterize the defects at high defect densities. We also carried out annealing studies of samples irradiated to the first stage and used an Arrhenius plot to measure activation energies for defect healing, Ea. We measured Ea = 0.90 eV for the graphene drums, consistent with the hydroxyl groups; for supported graphene, we measured Ea = 0.36 eV, consistent with hydrogen adsorbates. We also studied the surface of the drums using atomic force microscopy and found no observable holes after irradiation and annealing. Our results show that the local activation model is useful in characterizing the defects in graphene drums. 
    more » « less
  5. Twisted photonic crystals are photonic analogs of twisted monolayer materials such as graphene and their optical property studies are still in their infancy. This paper reports optical properties of twisted single-layer 2D+ moiré photonic crystals where there is a weak modulation in z direction, and bilayer moiré-overlapping-moiré photonic crystals. In weak-coupling bilayer moiré-overlapping-moiré photonic crystals, the light source is less localized with an increasing twist angle, similar to the results reported by the Harvard research group in References 37 and 38 on twisted bilayer photonic crystals, although there is a gradient pattern in the former case. In a strong-coupling case, however, the light source is tightly localized in AA-stacked region in bilayer PhCs with a large twist angle. For single-layer 2D+ moiré photonic crystals, the light source in Ex polarization can be localized and forms resonance modes when the single-layer 2D+ moiré photonic crystal is integrated on a glass substrate. This study leads to a potential application of 2D+ moiré photonic crystal in future on-chip optoelectronic integration. 
    more » « less
  6. Silicon nanotubes (Si NTs) have a unique structure among the silicon nanostructure family, which is useful for diverse applications ranging from therapeutics to lithium storage/recycling. Their well-defined structure and high surface area make them ideal for sensing applications. In this work, we demonstrate the formation of Au nanoparticles (NPs) functionalized with 4-Mercaptophenylboronic acid (MPBA) on porous Si NTs (pSi NTs) fabricated using ZnO nanowires as a template. The system was characterized, and the proposed structure was confirmed using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). Varying glucose concentrations in phosphate-buffered saline (PBS) (0.5–80 mM) were introduced to the Si NT nanocomposite system. The glucose is detectable at low concentrations utilizing surface-enhanced Raman spectroscopy (SERS), which shows a concentration-dependent peak shift in the benzene ring breathing mode (~1071 cm−1) of MPBA. Complementing these measurements are simulations of the Raman hot spots associated with plasmonic enhancement of the Au NPs using COMSOL. This biocompatible system is envisioned to have applications in nanomedicine and microfluidic devices for real-time, non-invasive glucose sensing. 
    more » « less