- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Adams, Taylor (1)
-
Aliee, Hananeh (1)
-
Allon, Samuel J. (1)
-
Andrusivova, Zaneta (1)
-
Angelidis, Ilias (1)
-
Ansari, Meshal (1)
-
Ashenberg, Orr (1)
-
Bassler, Kevin (1)
-
Benhar, Inbal (1)
-
Bergenstråhle, Joseph (1)
-
Bergenstråhle, Ludvig (1)
-
Bolt, Liam (1)
-
Braun, Emelie (1)
-
Buchanan, Justin (1)
-
Bui, Linh T. (1)
-
Bécavin, Christophe (1)
-
Cai, Peiwen (1)
-
Callori, Steven (1)
-
Chaffin, Mark (1)
-
Chen, Sijia (1)
-
- Filter by Editor
-
-
Jiang, Jingang (1)
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Jiang, Jingang (Ed.)Most current powered transfemoral prostheses are designed based on replicating normal anatomy with the inclusion of a revolute knee joint. Prosthesis users often have issues achieving proper leg length to maintain balance and perform push-off during stance, and to ensure sufficient toe clearance during swing. There is a clinical opportunity to develop a powered prosthesis that linearly shortens and lengthens during ambulation with a prismatic joint for improved leg length properties. To build on previous work, the research in this manuscript focuses on designing the physical device, the leg length actuation profile, and the control scheme. Based on gait analyses of two prosthesis users, the device provides an appropriate leg length actuation profile with sufficient shortening for toe clearance (exhibited by the greater prosthetic vs. intact side toe clearance) and lengthening for forward propulsion (exhibited by the ground reaction force peak in late stance). The device also has a motor torque and velocity capable of supporting up to a 90 kg user during normal ambulation, a control scheme with an adjustable actuation cycle based on gait cadence (matching within 2 ms), and a more compact mechanical system design (4.5 kg) less than anatomical weight requirements (5.5 kg). Additionally, the prosthesis users tested were highly encouraging of their stability, mobility, and safety while ambulating with the device.more » « less
-
Muus, Christoph; Luecken, Malte D.; Eraslan, Gökcen; Sikkema, Lisa; Waghray, Avinash; Heimberg, Graham; Kobayashi, Yoshihiko; Vaishnav, Eeshit Dhaval; Subramanian, Ayshwarya; Smillie, Christopher; et al (, Nature Medicine)null (Ed.)
An official website of the United States government
