- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0001000000000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Hasan, Ibrahim Mohammed (1)
-
Yumbla, Emiliano Quinones (1)
-
Zhang, Wenlong (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Wearable robotics has shown to be effective for assisting in activities of daily living and restoring motor functions. The objective of this research is to develop a soft robotic exosuit for knee flexion assistance during normal walking and validate its ability to reduce the efforts of the knee flexor muscles: biceps femoris (BF) and semitendinosus (SM). The exosuit is powered by an inflatable curved fabric actuator with the capability to generate flexion torques at the knee joint. An analytical model to characterize the torque of the proposed actuator is derived and validated experimentally. It is found that the analytical torque model precisely matches the experimental results such that the highest root mean square error (RMSE) obtained is 1.237 Nm while the lowest is 0.188 Nm. In addition, the derived model outperformed a benchmark torque model such that its minimum and maximum RMSEs are approximately 90% and 70% less than the benchmark model respectively. A prototype of the knee exosuit is fabricated and tested on one healthy subject with different operating conditions to assist knee flexion during normal walking. The results show that by choosing the appropriate timing of inflation, the exosuit can reduce the electromyography activity of the BF and the SM by 32% and 23%, respectively, without impeding the knee extensor muscle or reducing the knee's range of motion.more » « less