Search for: All records

Creators/Authors contains: "Ippolito, V."

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. We report the first search for nuclear ultra-heavy dark matter (UHDM) in a dual-phase liquid argon time projection chamber using the DarkSide-50 experiment. Unlike conventional weakly interacting massive particles (WIMPs), nuclear UHDM candidates may be composed of many dark nucleons and scatter numerous times while passing through the detector. Accounting for energy loss through the Earth's overburden, we apply selection criteria optimized for multi-scatter event topologies using the 532-day low-radiation campaign of the DarkSide-50 detector. Excluded limits on the UHDM-nucleon scattering cross section for dark nucleon masses of mχ=10,50,100,500GeV/c2 are presented. 
    more » « less
    Free, publicly-accessible full text available July 1, 2027
  2. Free, publicly-accessible full text available December 1, 2026
  3. Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass weakly interacting massive particle (WIMP) interactions, setting new world-leading constraints in the 13GeV/c2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates. 
    more » « less
    Free, publicly-accessible full text available June 1, 2027
  4. Abstract Directional sensitivity to nuclear recoils would provide a smoking gun for a possible discovery of dark matter in the form of WIMPs (Weakly Interacting Massive Particles). A hint of directional dependence of the response of a dual-phase argon Time Projection Chamber (TPC) was found in the SCENE experiment. Given the potential importance of such a capability in the framework of dark matter searches, a new dedicated experiment, ReD (Recoil Directionality), was designed by the Global Argon Dark Matter Collaboration, in order to scrutinise this hint. A small dual-phase argon TPC was irradiated with neutrons produced by the p(7Li,7Be)n reaction using the 15 MV TANDEM accelerator of the INFN - Laboratori Nazionali del Sud, Catania, Italy, so as to produce argon nuclear recoils in the range (20 - 100) keV of interest for dark matter searches. Energy and direction of nuclear recoils are inferred by the detection of the elastically-scattered neutron by a set of scintillation detectors. Events were selected by gating of the associated7Be, which is detected by a telescope of Si detectors. 
    more » « less
  5. Capone, A; De_Vincenzi, M; Morselli, A (Ed.)
    In the direct searches for Weakly Interacting Massive Particles (WIMPs) as Dark Matter candidates, the sensitivity of the detector to the incom- ing particle direction could provide a smoking gun signature for an interesting event. The SCENE collaboration firstly suggested the possible directional de- pendence of a dual-phase argon Time Projection Chamber through the columnar recombination effect. The Recoil Directionality project (ReD) within the Global Argon Dark Matter Collaboration aims to characterize the light and charge re- sponse of a liquid Argon dual-phase TPC to neutron-induced nuclear recoils to probe for the hint by SCENE. In this work, the directional sensitivity of the de- tector in the energy range of interest for WIMPs (20-100 keV) is investigated with a data-driven analysis involving a Machine Learning algorithm. 
    more » « less
  6. Abstract The DarkSide-20k dark matter direct detection experiment will employ a$${21}\,\hbox {m}^{2}$$ 21m2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors calledTiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout.$$16$$ 16 Tiles are further grouped intoPhoto-Detector Units(PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment. 
    more » « less
    Free, publicly-accessible full text available November 1, 2026
  7. Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eVee , the lowest threshold ever achieved in such a search. Published by the American Physical Society2024 
    more » « less
  8. Free, publicly-accessible full text available June 1, 2027
  9. Abstract The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of83mKr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors. 
    more » « less
  10. Abstract The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction. 
    more » « less