Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz ( ) range, and to axions with over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of , which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a live scan time of 2.9 years.more » « lessFree, publicly-accessible full text available September 1, 2026
-
Abstract Millimeter-wave refracting telescopes targeting the degree-scale structure of the cosmic microwave background (CMB) have recently grown to diffraction-limited apertures of over 0.5 m. These instruments are entirely housed in vacuum cryostats to support their subkelvin bolometric detectors and to minimize radiative loading from thermal emission due to absorption loss in their transmissive optical elements. The large vacuum window is the only optical element in the system at ambient temperature, and therefore minimizing loss in the window is crucial for maximizing detector sensitivity. This motivates the use of low-loss polymer materials and a window as thin as practicable. However, the window must simultaneously meet the requirement to keep a sufficient vacuum, and therefore must limit gas permeation and remain mechanically robust against catastrophic failure under pressure. We report on the development of extremely thin composite polyethylene window technology that meets these goals. Two windows have been deployed for two full observing seasons on the BICEP3 and the 150 GHz BICEP Array receiver CMB telescopes at the South Pole. On BICEP3, the window has demonstrated a 6% improvement in detector sensitivity.more » « lessFree, publicly-accessible full text available March 26, 2027
-
We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m3 axion search, which uses dc SQUIDs in this frequency range.more » « lessFree, publicly-accessible full text available September 7, 2026
-
We present component-separated polarization maps of the cosmic microwave background (CMB) and Galactic thermal dust emission, derived using data from the BICEP/Keck experiments through the 2018 observing season and Planck. By employing a maximum-likelihood method that utilizes observing matrices, we produce unbiased maps of the CMB and dust signals. We outline the computational challenges and demonstrate an efficient implementation of the component map estimator. We show methods to compute and characterize power spectra of these maps, opening up an alternative way to infer the tensor-to-scalar ratio from our data. We compare the results of this map-based separation method with the baseline BICEP/Keck analysis. Our analysis demonstrates consistency between the two methods, finding an 84% correlation between the pipelines.more » « lessFree, publicly-accessible full text available February 25, 2027
-
Free, publicly-accessible full text available September 25, 2026
An official website of the United States government

Full Text Available