Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology, high-voltage electrodes are instrumental for the generation of observable signals and their physical interpretation. Thus, electrode design and manufacturing has to fulfill stringent requirements, and their production is associated with significant engineering challenges. In this work we describe the successful development of electrodes on the 1.5 m-scale, from their design and simulation to subsequent assembly and high-voltage testing in a gaseous argon environment. The produced electrodes were recently installed as an anode and a cathode during an upgrade to the XENONnT experiment.more » « lessFree, publicly-accessible full text available February 1, 2027
-
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used an Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of between 0.3 (0.7) and . This calibration is crucial for accurately measuring the solar neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below .more » « lessFree, publicly-accessible full text available June 1, 2027
-
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.more » « lessFree, publicly-accessible full text available March 1, 2027
-
Abstract The control of the in-plane domain evolution in ferroelectric thin films is not only critical to understanding ferroelectric phenomena but also to enabling functional device fabrication. However, in-plane polarized ferroelectric thin films typically exhibit complicated multi-domain states, not desirable for optoelectronic device performance. Here we report a strategy combining interfacial symmetry engineering and anisotropic strain to design single-domain, in-plane polarized ferroelectric BaTiO 3 thin films. Theoretical calculations predict the key role of the BaTiO 3 /PrScO 3 $${({{{{{\boldsymbol{110}}}}}})}_{{{{{{\bf{O}}}}}}}$$ ( 110 ) O substrate interfacial environment, where anisotropic strain, monoclinic distortions, and interfacial electrostatic potential stabilize a single-variant spontaneous polarization. A combination of scanning transmission electron microscopy, piezoresponse force microscopy, ferroelectric hysteresis loop measurements, and second harmonic generation measurements directly reveals the stabilization of the in-plane quasi-single-domain polarization state. This work offers design principles for engineering in-plane domains of ferroelectric oxide thin films, which is a prerequisite for high performance optoelectronic devices.more » « less
-
Abstract Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) can tag neutrons via their capture on gadolinium or hydrogen, which release$$\gamma $$ -rays that are subsequently detected as Cherenkov light. In this work, we present the first results of the XENONnT NV when operated with demineralized water only, before the insertion of gadolinium. Its efficiency for detecting neutrons is$$({82\pm 1}){\%}$$ , the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of$$({53\pm 3}){\%}$$ for the tagging of WIMP-like neutron signals, inside a tagging time window of$${250}~{\upmu }\hbox {s}$$ between TPC and NV, leading to a livetime loss of$${1.6}{\%}$$ during the first science run of XENONnT.more » « less
-
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of 3.1 tonne-years. In a blind analysis of nuclear recoil events with energies above 3.8 keVNR, we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross section for WIMP masses above 10 GeV/𝑐2 with a minimum of 1.7×10−47 cm2 at 90% confidence level for a WIMP mass of 30 GeV/𝑐2. We achieve a best median sensitivity of 1.4×10−47 cm2 for a 41 GeV/𝑐2 WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.more » « lessFree, publicly-accessible full text available November 24, 2026
-
We report on a blinded search for dark matter with single- and few-electron signals in the first science run of XENONnT relying on a novel detector response framework that is physics model dependent. We derive 90% confidence upper limits for dark matter-electron interactions. Heavy and light mediator cases are considered for the standard halo model and dark matter up-scattered in the Sun. We set stringent new limits on dark matter-electron scattering via a heavy mediator with a mass within and electron absorption of axionlike particles and dark photons for below . Published by the American Physical Society2025more » « less
An official website of the United States government

Full Text Available