- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Johnson, W. Brett (1)
-
Mukul, Pooja (1)
-
Prost, Victor (1)
-
Winter V, Amos G. (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract A novel, high-performance, cosmetic, rugged, appropriately costed, and mass-manufacturable prosthetic foot for use in low-income countries was designed and field tested. This ruggedized foot was created to accommodate the unique economic, environmental, and cultural requirements for users in India. A previous prototype that enabled able-bodied like gait was modified to include a durable cosmetic cover without altering the tuned stiffness of the overall foot. After undergoing mechanical benchtop testing, the foot was distributed to prosthesis users in India to for at least 5 months. Afterward, participants underwent clinical tests to evaluate walking performance, and additional benchtop testing was performed on the field-tested feet to identify changes in performance. The ruggedized foot endured 1 × 106 fatigue cycles without failure and demonstrated the desired stiffness properties. Subjects walked significantly faster (0.14 m/s) with the ruggedized foot compared to the Jaipur foot, and the feet showed no visible sign of damage after months of use. Additionally, the field-tested feet showed little difference in stiffness from a set of unused controls. Anecdotal feedback from the participants indicated that the foot improved their speed and/or walking effort, but may benefit from more degrees-of-freedom about the ankle. The results suggest that the foot fulfills its design requirements; however, further field testing is required with more participants over a longer period to make sure the foot is suitable for use in developing countries.more » « less
An official website of the United States government
