- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Frames, C. (2)
-
Moon, S.H. (2)
-
Soangra, R. (2)
-
and Lockhart, T. (2)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Various factors are responsible for injuries that occur in the U.S. Army soldiers. In particular, rucksack load carriage equipment influences the stability of the lower extremities and possibly affects gait balance. The objective of this investigation was to assess the gait and local dynamic stability of the lower extremity of five subjects as they performed a simulated rucksack march on a treadmill. The Motek Gait Real-time Interactive Laboratory (GRAIL) was utilized to replicate the environment of the rucksack march. The first walking trial was without a rucksack and the second set was executed with the All-Purpose Lightweight Individual Carrying Equipment (ALICE), an older version of the rucksack, and the third set was executed with the newer rucksack version, Modular Lightweight Load Carrying Equipment (MOLLE). In this experiment, the Inertial Measurement Unit (IMU) system, Dynaport was used to measure the ambulatory data of the subject. This experiment required subjects to walk continuously for 200 seconds with a 20kg rucksack, which simulates the real rucksack march training. To determine the dynamic stability of different load carriage and normal walking condition, Local Dynamic Stability (LDS) was calculated to quantify its stability. The results presented that comparing Maximum Lyapunov Exponent (LyE) of normal walking was significantly lower compared to ALICE (P=0.000007) and MOLLE (P=0.00003), however, between ALICE and MOLLE rucksack walking showed no significant difference (P=0.441). The five subjects showed significantly improved dynamic stability when walking without a rucksack in comparison with wearing the equipment. In conclusion, we discovered wearing a rucksack result in a significant (P < 0.0001) reduction in dynamic stability.more » « less
-
Moon, S.H.; Soangra, R.; Frames, C.; and Lockhart, T. (, Biomedical sciences instrumentation)Parkinson’s Disease (PD) is a neurodegenerative disorder affecting the substantia nigra, which leads to more than half of PD patients are considered to be at high risk of falling. Recently, Inertial Measurement Unit (IMU) sensors have shown great promise in the classification of activities of daily living (ADL) such as walking, standing, sitting, and laying down, considered to be normal movement in daily life. Measuring physical activity level from longitudinal ADL monitoring among PD patients could provide insights into their fall mechanisms. In this study, six PD patients (mean age=74.3±6.5 years) and six young healthy subjects (mean age=19.7±2.7 years) were recruited. All the subjects were asked to wear the single accelerometer, DynaPort MM+ (Motion Monitor+, McRoberts BV, The Hague, Netherlands), with a sampling frequency of 100 Hz located at the L5-S1 spinal area for 3 days. Subjects maintained a log of activities they performed and only removed the sensor while showering or performing other aquatic activities. The resultant acceleration was filtered using high and low pass Butterworth filters to determine dynamic and stationary activities. As a result, it was found that healthy young subjects performed significantly more dynamic activities (13.2%) when compared to PD subjects (7%), in contrast, PD subjects (92.9%) had significantly more stationary activities than young healthy subjects (86.8%).more » « less
An official website of the United States government

Full Text Available